Investigation of Cast Iron Matrix Constituents by Magnetic Adaptive Testing

G. Vértesy, I. Tomas, B. Skrbek, T. Uchimoto, T. Takagi

Research output: Contribution to journalArticle

Abstract

Two types of cast iron materials - flake graphite cast iron and ductile cast iron - were investigated by the method of magnetic adaptive testing, which is based on the systematic measurement and the evaluation of minor magnetic hysteresis loops. In all cases, even within the same type of material rather big differences existed considering both the chemical composition and the material structure of the investigated sample series. The matrix structure was determined by traditional metallographic examination, and these values were compared with the non-destructively measured magnetic parameters. It was shown that the relative pearlite volume fraction of the metallic matrix of cast iron samples could be determined by this method with a good reliability. The same is true also for the relative chill content of the matrix, as long as the samples contain chill at all. A general expression was found to characterize those correlations, which do not depend on the actual sample and neither on the applied parameters of the concrete magnetic measurement.

Original languageEnglish
Article number8630686
JournalIEEE Transactions on Magnetics
Volume55
Issue number3
DOIs
Publication statusPublished - Mar 1 2019

Fingerprint

Cast iron
Testing
Magnetic hysteresis
Graphite
Pearlite
Magnetic variables measurement
Hysteresis loops
Volume fraction
Concretes
Chemical analysis

Keywords

  • Cast iron
  • magnetic adaptive testing (MAT)
  • magnetic non-destructive evaluation (NDE)
  • pearlite content

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Electrical and Electronic Engineering

Cite this

Investigation of Cast Iron Matrix Constituents by Magnetic Adaptive Testing. / Vértesy, G.; Tomas, I.; Skrbek, B.; Uchimoto, T.; Takagi, T.

In: IEEE Transactions on Magnetics, Vol. 55, No. 3, 8630686, 01.03.2019.

Research output: Contribution to journalArticle

Vértesy, G. ; Tomas, I. ; Skrbek, B. ; Uchimoto, T. ; Takagi, T. / Investigation of Cast Iron Matrix Constituents by Magnetic Adaptive Testing. In: IEEE Transactions on Magnetics. 2019 ; Vol. 55, No. 3.
@article{f428abeb6e7846a385fa7167cfa25320,
title = "Investigation of Cast Iron Matrix Constituents by Magnetic Adaptive Testing",
abstract = "Two types of cast iron materials - flake graphite cast iron and ductile cast iron - were investigated by the method of magnetic adaptive testing, which is based on the systematic measurement and the evaluation of minor magnetic hysteresis loops. In all cases, even within the same type of material rather big differences existed considering both the chemical composition and the material structure of the investigated sample series. The matrix structure was determined by traditional metallographic examination, and these values were compared with the non-destructively measured magnetic parameters. It was shown that the relative pearlite volume fraction of the metallic matrix of cast iron samples could be determined by this method with a good reliability. The same is true also for the relative chill content of the matrix, as long as the samples contain chill at all. A general expression was found to characterize those correlations, which do not depend on the actual sample and neither on the applied parameters of the concrete magnetic measurement.",
keywords = "Cast iron, magnetic adaptive testing (MAT), magnetic non-destructive evaluation (NDE), pearlite content",
author = "G. V{\'e}rtesy and I. Tomas and B. Skrbek and T. Uchimoto and T. Takagi",
year = "2019",
month = "3",
day = "1",
doi = "10.1109/TMAG.2019.2892683",
language = "English",
volume = "55",
journal = "IEEE Transactions on Magnetics",
issn = "0018-9464",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "3",

}

TY - JOUR

T1 - Investigation of Cast Iron Matrix Constituents by Magnetic Adaptive Testing

AU - Vértesy, G.

AU - Tomas, I.

AU - Skrbek, B.

AU - Uchimoto, T.

AU - Takagi, T.

PY - 2019/3/1

Y1 - 2019/3/1

N2 - Two types of cast iron materials - flake graphite cast iron and ductile cast iron - were investigated by the method of magnetic adaptive testing, which is based on the systematic measurement and the evaluation of minor magnetic hysteresis loops. In all cases, even within the same type of material rather big differences existed considering both the chemical composition and the material structure of the investigated sample series. The matrix structure was determined by traditional metallographic examination, and these values were compared with the non-destructively measured magnetic parameters. It was shown that the relative pearlite volume fraction of the metallic matrix of cast iron samples could be determined by this method with a good reliability. The same is true also for the relative chill content of the matrix, as long as the samples contain chill at all. A general expression was found to characterize those correlations, which do not depend on the actual sample and neither on the applied parameters of the concrete magnetic measurement.

AB - Two types of cast iron materials - flake graphite cast iron and ductile cast iron - were investigated by the method of magnetic adaptive testing, which is based on the systematic measurement and the evaluation of minor magnetic hysteresis loops. In all cases, even within the same type of material rather big differences existed considering both the chemical composition and the material structure of the investigated sample series. The matrix structure was determined by traditional metallographic examination, and these values were compared with the non-destructively measured magnetic parameters. It was shown that the relative pearlite volume fraction of the metallic matrix of cast iron samples could be determined by this method with a good reliability. The same is true also for the relative chill content of the matrix, as long as the samples contain chill at all. A general expression was found to characterize those correlations, which do not depend on the actual sample and neither on the applied parameters of the concrete magnetic measurement.

KW - Cast iron

KW - magnetic adaptive testing (MAT)

KW - magnetic non-destructive evaluation (NDE)

KW - pearlite content

UR - http://www.scopus.com/inward/record.url?scp=85062212837&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85062212837&partnerID=8YFLogxK

U2 - 10.1109/TMAG.2019.2892683

DO - 10.1109/TMAG.2019.2892683

M3 - Article

VL - 55

JO - IEEE Transactions on Magnetics

JF - IEEE Transactions on Magnetics

SN - 0018-9464

IS - 3

M1 - 8630686