Inter-comparison of optical absorption coefficients of atmospheric aerosols determined by a multi-wavelength photoacoustic spectrometer and an Aethalometer under sub-urban wintry conditions

Tibor Ajtai, Ágnes Filep, Noémi Utry, Martin Schnaiter, Claudia Linke, Z. Bozóki, Gábor Szabó, Thomas Leisner

Research output: Contribution to journalArticle

27 Citations (Scopus)

Abstract

The wavelength-dependent optical absorption coefficients (OACs) of atmospheric aerosols were measured at a sub-urban site in Budapest under wintry conditions simultaneously with a commercially available, seven-wavelength (7 λ) Aethalometer instrument, and with a recently developed four-wavelength (1064, 532, 355 and 266. nm) photoacoustic spectrometer (4 λ-PAS). While there is a good agreement between the readings on the two systems in the near-infrared and in the visible, the OACs measured by the 4 λ-PAS in the UV region were systematically higher than the OACs extrapolated to the UV region from data measured in the visible by the Aethalometer, and the relative deviation between the readings of the instruments in the UV was found to increase exponentially as a function of the Ångström exponent fitted to the wavelength dependency measured by either system. This result indicates that the 4 λ-PAS has more diagnostic value than the Aethalometer, i.e. it has higher sensitivity to discriminate between different aerosol sources. Furthermore, our finding can significantly affect the results of radiative transfer calculations for atmospheric aerosols, in which wavelength-dependent optical absorption, usually measured by Aethalometers, is an important input parameter.

Original languageEnglish
Pages (from-to)859-866
Number of pages8
JournalJournal of Aerosol Science
Volume42
Issue number12
DOIs
Publication statusPublished - Dec 2011

Fingerprint

Atmospheric aerosols
Photoacoustic effect
absorption coefficient
Light absorption
Spectrometers
spectrometer
aerosol
wavelength
Wavelength
Radiative transfer
urban site
Aerosols
radiative transfer
near infrared
comparison
Infrared radiation

Keywords

  • Aerosol
  • Angström exponent
  • Optical absorption
  • Photoacoustic
  • Wavelength dependence

ASJC Scopus subject areas

  • Materials Science(all)
  • Environmental Chemistry
  • Pollution

Cite this

Inter-comparison of optical absorption coefficients of atmospheric aerosols determined by a multi-wavelength photoacoustic spectrometer and an Aethalometer under sub-urban wintry conditions. / Ajtai, Tibor; Filep, Ágnes; Utry, Noémi; Schnaiter, Martin; Linke, Claudia; Bozóki, Z.; Szabó, Gábor; Leisner, Thomas.

In: Journal of Aerosol Science, Vol. 42, No. 12, 12.2011, p. 859-866.

Research output: Contribution to journalArticle

Ajtai, Tibor ; Filep, Ágnes ; Utry, Noémi ; Schnaiter, Martin ; Linke, Claudia ; Bozóki, Z. ; Szabó, Gábor ; Leisner, Thomas. / Inter-comparison of optical absorption coefficients of atmospheric aerosols determined by a multi-wavelength photoacoustic spectrometer and an Aethalometer under sub-urban wintry conditions. In: Journal of Aerosol Science. 2011 ; Vol. 42, No. 12. pp. 859-866.
@article{f8af69e411274ad197bb10d0fb325205,
title = "Inter-comparison of optical absorption coefficients of atmospheric aerosols determined by a multi-wavelength photoacoustic spectrometer and an Aethalometer under sub-urban wintry conditions",
abstract = "The wavelength-dependent optical absorption coefficients (OACs) of atmospheric aerosols were measured at a sub-urban site in Budapest under wintry conditions simultaneously with a commercially available, seven-wavelength (7 λ) Aethalometer instrument, and with a recently developed four-wavelength (1064, 532, 355 and 266. nm) photoacoustic spectrometer (4 λ-PAS). While there is a good agreement between the readings on the two systems in the near-infrared and in the visible, the OACs measured by the 4 λ-PAS in the UV region were systematically higher than the OACs extrapolated to the UV region from data measured in the visible by the Aethalometer, and the relative deviation between the readings of the instruments in the UV was found to increase exponentially as a function of the {\AA}ngstr{\"o}m exponent fitted to the wavelength dependency measured by either system. This result indicates that the 4 λ-PAS has more diagnostic value than the Aethalometer, i.e. it has higher sensitivity to discriminate between different aerosol sources. Furthermore, our finding can significantly affect the results of radiative transfer calculations for atmospheric aerosols, in which wavelength-dependent optical absorption, usually measured by Aethalometers, is an important input parameter.",
keywords = "Aerosol, Angstr{\"o}m exponent, Optical absorption, Photoacoustic, Wavelength dependence",
author = "Tibor Ajtai and {\'A}gnes Filep and No{\'e}mi Utry and Martin Schnaiter and Claudia Linke and Z. Boz{\'o}ki and G{\'a}bor Szab{\'o} and Thomas Leisner",
year = "2011",
month = "12",
doi = "10.1016/j.jaerosci.2011.07.008",
language = "English",
volume = "42",
pages = "859--866",
journal = "Journal of Aerosol Science",
issn = "0021-8502",
publisher = "Elsevier Limited",
number = "12",

}

TY - JOUR

T1 - Inter-comparison of optical absorption coefficients of atmospheric aerosols determined by a multi-wavelength photoacoustic spectrometer and an Aethalometer under sub-urban wintry conditions

AU - Ajtai, Tibor

AU - Filep, Ágnes

AU - Utry, Noémi

AU - Schnaiter, Martin

AU - Linke, Claudia

AU - Bozóki, Z.

AU - Szabó, Gábor

AU - Leisner, Thomas

PY - 2011/12

Y1 - 2011/12

N2 - The wavelength-dependent optical absorption coefficients (OACs) of atmospheric aerosols were measured at a sub-urban site in Budapest under wintry conditions simultaneously with a commercially available, seven-wavelength (7 λ) Aethalometer instrument, and with a recently developed four-wavelength (1064, 532, 355 and 266. nm) photoacoustic spectrometer (4 λ-PAS). While there is a good agreement between the readings on the two systems in the near-infrared and in the visible, the OACs measured by the 4 λ-PAS in the UV region were systematically higher than the OACs extrapolated to the UV region from data measured in the visible by the Aethalometer, and the relative deviation between the readings of the instruments in the UV was found to increase exponentially as a function of the Ångström exponent fitted to the wavelength dependency measured by either system. This result indicates that the 4 λ-PAS has more diagnostic value than the Aethalometer, i.e. it has higher sensitivity to discriminate between different aerosol sources. Furthermore, our finding can significantly affect the results of radiative transfer calculations for atmospheric aerosols, in which wavelength-dependent optical absorption, usually measured by Aethalometers, is an important input parameter.

AB - The wavelength-dependent optical absorption coefficients (OACs) of atmospheric aerosols were measured at a sub-urban site in Budapest under wintry conditions simultaneously with a commercially available, seven-wavelength (7 λ) Aethalometer instrument, and with a recently developed four-wavelength (1064, 532, 355 and 266. nm) photoacoustic spectrometer (4 λ-PAS). While there is a good agreement between the readings on the two systems in the near-infrared and in the visible, the OACs measured by the 4 λ-PAS in the UV region were systematically higher than the OACs extrapolated to the UV region from data measured in the visible by the Aethalometer, and the relative deviation between the readings of the instruments in the UV was found to increase exponentially as a function of the Ångström exponent fitted to the wavelength dependency measured by either system. This result indicates that the 4 λ-PAS has more diagnostic value than the Aethalometer, i.e. it has higher sensitivity to discriminate between different aerosol sources. Furthermore, our finding can significantly affect the results of radiative transfer calculations for atmospheric aerosols, in which wavelength-dependent optical absorption, usually measured by Aethalometers, is an important input parameter.

KW - Aerosol

KW - Angström exponent

KW - Optical absorption

KW - Photoacoustic

KW - Wavelength dependence

UR - http://www.scopus.com/inward/record.url?scp=80052551343&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80052551343&partnerID=8YFLogxK

U2 - 10.1016/j.jaerosci.2011.07.008

DO - 10.1016/j.jaerosci.2011.07.008

M3 - Article

VL - 42

SP - 859

EP - 866

JO - Journal of Aerosol Science

JF - Journal of Aerosol Science

SN - 0021-8502

IS - 12

ER -