Andrea Spinazzè, Davide Campagnolo, Andrea Cattaneo, Patrizia Urso, Ioannis A. Sakellaris, Dikaia E. Saraga, Corinne Mandin, Nuno Canha, Rosanna Mabilia, Erica Perreca, Victor G. Mihucz, Tamás Szigeti, Gabriela Ventura, Eduardo de Oliveira Fernandes, Yvonne de Kluizenaar, Eric Cornelissen, Otto Hänninen, Paolo Carrer, Peder Wolkoff, Domenico M. CavalloJohn G. Bartzis

Research output: Contribution to journalArticle

Abstract

The aim of this study was to identify determinants of aldehyde and volatile organic compound (VOC) indoor air concentrations in a sample of more than 140 office rooms, in the framework of the European OFFICAIR research project. A large field campaign was performed, which included (a) the air sampling of aldehydes and VOCs in 37 newly built or recently retrofitted office buildings across 8 European countries in summer and winter and (b) the collection of information on building and offices’ characteristics using checklists. Linear mixed models for repeated measurements were applied to identify the main factors affecting the measured concentrations of selected indoor air pollutants (IAPs). Several associations between aldehydes and VOCs concentrations and buildings’ structural characteristic or occupants’ activity patterns were identified. The aldehyde and VOC determinants in office buildings include building and furnishing materials, indoor climate characteristics (room temperature and relative humidity), the use of consumer products (eg, cleaning and personal care products, office equipment), as well as the presence of outdoor sources in the proximity of the buildings (ie, vehicular traffic). Results also showed that determinants of indoor air concentrations varied considerably among different type of pollutants.

Original languageEnglish
JournalIndoor Air
DOIs
Publication statusAccepted/In press - Jan 1 2019

Fingerprint

Air Pollutants
Aldehydes
Volatile organic compounds
Volatile Organic Compounds
Office buildings
Air
Office equipment
Consumer products
Humidity
Checklist
Climate
Cleaning
Linear Models
Atmospheric humidity
Sampling
Equipment and Supplies
Temperature
Research

Keywords

  • carbonyls
  • indoor air quality
  • indoor environmental quality
  • indoor exposure
  • predictors
  • risk management
  • volatile organic compounds

ASJC Scopus subject areas

  • Environmental Engineering
  • Building and Construction
  • Public Health, Environmental and Occupational Health

Cite this

Spinazzè, A., Campagnolo, D., Cattaneo, A., Urso, P., Sakellaris, I. A., Saraga, D. E., ... Bartzis, J. G. (Accepted/In press). Indoor gaseous air pollutants determinants in office buildings—The OFFICAIR project. Indoor Air. https://doi.org/10.1111/ina.12609

Indoor gaseous air pollutants determinants in office buildings—The OFFICAIR project. / Spinazzè, Andrea; Campagnolo, Davide; Cattaneo, Andrea; Urso, Patrizia; Sakellaris, Ioannis A.; Saraga, Dikaia E.; Mandin, Corinne; Canha, Nuno; Mabilia, Rosanna; Perreca, Erica; Mihucz, Victor G.; Szigeti, Tamás; Ventura, Gabriela; de Oliveira Fernandes, Eduardo; de Kluizenaar, Yvonne; Cornelissen, Eric; Hänninen, Otto; Carrer, Paolo; Wolkoff, Peder; Cavallo, Domenico M.; Bartzis, John G.

In: Indoor Air, 01.01.2019.

Research output: Contribution to journalArticle

Spinazzè, A, Campagnolo, D, Cattaneo, A, Urso, P, Sakellaris, IA, Saraga, DE, Mandin, C, Canha, N, Mabilia, R, Perreca, E, Mihucz, VG, Szigeti, T, Ventura, G, de Oliveira Fernandes, E, de Kluizenaar, Y, Cornelissen, E, Hänninen, O, Carrer, P, Wolkoff, P, Cavallo, DM & Bartzis, JG 2019, 'Indoor gaseous air pollutants determinants in office buildings—The OFFICAIR project', Indoor Air. https://doi.org/10.1111/ina.12609
Spinazzè A, Campagnolo D, Cattaneo A, Urso P, Sakellaris IA, Saraga DE et al. Indoor gaseous air pollutants determinants in office buildings—The OFFICAIR project. Indoor Air. 2019 Jan 1. https://doi.org/10.1111/ina.12609
Spinazzè, Andrea ; Campagnolo, Davide ; Cattaneo, Andrea ; Urso, Patrizia ; Sakellaris, Ioannis A. ; Saraga, Dikaia E. ; Mandin, Corinne ; Canha, Nuno ; Mabilia, Rosanna ; Perreca, Erica ; Mihucz, Victor G. ; Szigeti, Tamás ; Ventura, Gabriela ; de Oliveira Fernandes, Eduardo ; de Kluizenaar, Yvonne ; Cornelissen, Eric ; Hänninen, Otto ; Carrer, Paolo ; Wolkoff, Peder ; Cavallo, Domenico M. ; Bartzis, John G. / Indoor gaseous air pollutants determinants in office buildings—The OFFICAIR project. In: Indoor Air. 2019.
@article{2d5bb16392f04c5eb3dc910bcf6b6790,
title = "Indoor gaseous air pollutants determinants in office buildings—The OFFICAIR project",
abstract = "The aim of this study was to identify determinants of aldehyde and volatile organic compound (VOC) indoor air concentrations in a sample of more than 140 office rooms, in the framework of the European OFFICAIR research project. A large field campaign was performed, which included (a) the air sampling of aldehydes and VOCs in 37 newly built or recently retrofitted office buildings across 8 European countries in summer and winter and (b) the collection of information on building and offices’ characteristics using checklists. Linear mixed models for repeated measurements were applied to identify the main factors affecting the measured concentrations of selected indoor air pollutants (IAPs). Several associations between aldehydes and VOCs concentrations and buildings’ structural characteristic or occupants’ activity patterns were identified. The aldehyde and VOC determinants in office buildings include building and furnishing materials, indoor climate characteristics (room temperature and relative humidity), the use of consumer products (eg, cleaning and personal care products, office equipment), as well as the presence of outdoor sources in the proximity of the buildings (ie, vehicular traffic). Results also showed that determinants of indoor air concentrations varied considerably among different type of pollutants.",
keywords = "carbonyls, indoor air quality, indoor environmental quality, indoor exposure, predictors, risk management, volatile organic compounds",
author = "Andrea Spinazz{\`e} and Davide Campagnolo and Andrea Cattaneo and Patrizia Urso and Sakellaris, {Ioannis A.} and Saraga, {Dikaia E.} and Corinne Mandin and Nuno Canha and Rosanna Mabilia and Erica Perreca and Mihucz, {Victor G.} and Tam{\'a}s Szigeti and Gabriela Ventura and {de Oliveira Fernandes}, Eduardo and {de Kluizenaar}, Yvonne and Eric Cornelissen and Otto H{\"a}nninen and Paolo Carrer and Peder Wolkoff and Cavallo, {Domenico M.} and Bartzis, {John G.}",
year = "2019",
month = "1",
day = "1",
doi = "10.1111/ina.12609",
language = "English",
journal = "Indoor Air",
issn = "0905-6947",
publisher = "Blackwell Munksgaard",

}

TY - JOUR

T1 - Indoor gaseous air pollutants determinants in office buildings—The OFFICAIR project

AU - Spinazzè, Andrea

AU - Campagnolo, Davide

AU - Cattaneo, Andrea

AU - Urso, Patrizia

AU - Sakellaris, Ioannis A.

AU - Saraga, Dikaia E.

AU - Mandin, Corinne

AU - Canha, Nuno

AU - Mabilia, Rosanna

AU - Perreca, Erica

AU - Mihucz, Victor G.

AU - Szigeti, Tamás

AU - Ventura, Gabriela

AU - de Oliveira Fernandes, Eduardo

AU - de Kluizenaar, Yvonne

AU - Cornelissen, Eric

AU - Hänninen, Otto

AU - Carrer, Paolo

AU - Wolkoff, Peder

AU - Cavallo, Domenico M.

AU - Bartzis, John G.

PY - 2019/1/1

Y1 - 2019/1/1

N2 - The aim of this study was to identify determinants of aldehyde and volatile organic compound (VOC) indoor air concentrations in a sample of more than 140 office rooms, in the framework of the European OFFICAIR research project. A large field campaign was performed, which included (a) the air sampling of aldehydes and VOCs in 37 newly built or recently retrofitted office buildings across 8 European countries in summer and winter and (b) the collection of information on building and offices’ characteristics using checklists. Linear mixed models for repeated measurements were applied to identify the main factors affecting the measured concentrations of selected indoor air pollutants (IAPs). Several associations between aldehydes and VOCs concentrations and buildings’ structural characteristic or occupants’ activity patterns were identified. The aldehyde and VOC determinants in office buildings include building and furnishing materials, indoor climate characteristics (room temperature and relative humidity), the use of consumer products (eg, cleaning and personal care products, office equipment), as well as the presence of outdoor sources in the proximity of the buildings (ie, vehicular traffic). Results also showed that determinants of indoor air concentrations varied considerably among different type of pollutants.

AB - The aim of this study was to identify determinants of aldehyde and volatile organic compound (VOC) indoor air concentrations in a sample of more than 140 office rooms, in the framework of the European OFFICAIR research project. A large field campaign was performed, which included (a) the air sampling of aldehydes and VOCs in 37 newly built or recently retrofitted office buildings across 8 European countries in summer and winter and (b) the collection of information on building and offices’ characteristics using checklists. Linear mixed models for repeated measurements were applied to identify the main factors affecting the measured concentrations of selected indoor air pollutants (IAPs). Several associations between aldehydes and VOCs concentrations and buildings’ structural characteristic or occupants’ activity patterns were identified. The aldehyde and VOC determinants in office buildings include building and furnishing materials, indoor climate characteristics (room temperature and relative humidity), the use of consumer products (eg, cleaning and personal care products, office equipment), as well as the presence of outdoor sources in the proximity of the buildings (ie, vehicular traffic). Results also showed that determinants of indoor air concentrations varied considerably among different type of pollutants.

KW - carbonyls

KW - indoor air quality

KW - indoor environmental quality

KW - indoor exposure

KW - predictors

KW - risk management

KW - volatile organic compounds

UR - http://www.scopus.com/inward/record.url?scp=85074372838&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85074372838&partnerID=8YFLogxK

U2 - 10.1111/ina.12609

DO - 10.1111/ina.12609

M3 - Article

AN - SCOPUS:85074372838

JO - Indoor Air

JF - Indoor Air

SN - 0905-6947

ER -