In vitro studies on the dissolution rate of industrial retarded urea feedingstuffs by use of a selective electrode. application of the potentiometric urea enzyme electrode in measurements of dissolution rate

Ildiko Fritz, G. Nagy, Lajos Fodor, Erno Pungor

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

An enzyme electrode based on the neutral carrier type ammonium ion selective electrode was prepared in order to study the rate of dissolution of urea. A procedure was developed that was found to be applicable for monitoring the urea dissolution process in different industrial feedingstuff additives containing urea.

Original languageEnglish
Pages (from-to)439-444
Number of pages6
JournalThe Analyst
Volume101
Issue number1203
Publication statusPublished - 1976

Fingerprint

Enzyme electrodes
Biosensing Techniques
Urea
urea
Electrodes
Dissolution
electrode
dissolution
enzyme
Ion-Selective Electrodes
Ion selective electrodes
Ammonium Compounds
ammonium
ion
Monitoring
monitoring
rate
In Vitro Techniques

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

@article{518c8750bb0948c7b02bd85037164cd1,
title = "In vitro studies on the dissolution rate of industrial retarded urea feedingstuffs by use of a selective electrode. application of the potentiometric urea enzyme electrode in measurements of dissolution rate",
abstract = "An enzyme electrode based on the neutral carrier type ammonium ion selective electrode was prepared in order to study the rate of dissolution of urea. A procedure was developed that was found to be applicable for monitoring the urea dissolution process in different industrial feedingstuff additives containing urea.",
author = "Ildiko Fritz and G. Nagy and Lajos Fodor and Erno Pungor",
year = "1976",
language = "English",
volume = "101",
pages = "439--444",
journal = "The Analyst",
issn = "0003-2654",
publisher = "Royal Society of Chemistry",
number = "1203",

}

TY - JOUR

T1 - In vitro studies on the dissolution rate of industrial retarded urea feedingstuffs by use of a selective electrode. application of the potentiometric urea enzyme electrode in measurements of dissolution rate

AU - Fritz, Ildiko

AU - Nagy, G.

AU - Fodor, Lajos

AU - Pungor, Erno

PY - 1976

Y1 - 1976

N2 - An enzyme electrode based on the neutral carrier type ammonium ion selective electrode was prepared in order to study the rate of dissolution of urea. A procedure was developed that was found to be applicable for monitoring the urea dissolution process in different industrial feedingstuff additives containing urea.

AB - An enzyme electrode based on the neutral carrier type ammonium ion selective electrode was prepared in order to study the rate of dissolution of urea. A procedure was developed that was found to be applicable for monitoring the urea dissolution process in different industrial feedingstuff additives containing urea.

UR - http://www.scopus.com/inward/record.url?scp=0016968674&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0016968674&partnerID=8YFLogxK

M3 - Article

C2 - 937731

AN - SCOPUS:0016968674

VL - 101

SP - 439

EP - 444

JO - The Analyst

JF - The Analyst

SN - 0003-2654

IS - 1203

ER -