In-beam determination of k0 factors for short-lived nuclides

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

The prompt γ-activation analysis (PGAA) facility at Budapest Research Reactor offers a unique possibility to perform in-beam measurements. Several k0 factors for decay γ-lines of short-lived nuclides have been determined accurately by means of in-beam activation. The present values compare well with literature data. New k0 factors are proposed for 24mNa and 60mCo.

Original languageEnglish
Pages (from-to)561-564
Number of pages4
JournalJournal of Radioanalytical and Nuclear Chemistry
Volume257
Issue number3
DOIs
Publication statusPublished - Sep 1 2003

Fingerprint

Activation analysis
Activation Analysis
Research reactors
Isotopes
Chemical activation
Research

ASJC Scopus subject areas

  • Analytical Chemistry
  • Inorganic Chemistry
  • Nuclear Energy and Engineering

Cite this

In-beam determination of k0 factors for short-lived nuclides. / Révay, Zs; Molnár, G.; Belgya, T.; Kasztovszky, Z.

In: Journal of Radioanalytical and Nuclear Chemistry, Vol. 257, No. 3, 01.09.2003, p. 561-564.

Research output: Contribution to journalArticle

@article{ef147dc2ed3f4a0e8873251792a6e68d,
title = "In-beam determination of k0 factors for short-lived nuclides",
abstract = "The prompt γ-activation analysis (PGAA) facility at Budapest Research Reactor offers a unique possibility to perform in-beam measurements. Several k0 factors for decay γ-lines of short-lived nuclides have been determined accurately by means of in-beam activation. The present values compare well with literature data. New k0 factors are proposed for 24mNa and 60mCo.",
author = "Zs R{\'e}vay and G. Moln{\'a}r and T. Belgya and Z. Kasztovszky",
year = "2003",
month = "9",
day = "1",
doi = "10.1023/A:1025440631733",
language = "English",
volume = "257",
pages = "561--564",
journal = "Journal of Radioanalytical and Nuclear Chemistry",
issn = "0022-4081",
publisher = "Elsevier BV",
number = "3",

}

TY - JOUR

T1 - In-beam determination of k0 factors for short-lived nuclides

AU - Révay, Zs

AU - Molnár, G.

AU - Belgya, T.

AU - Kasztovszky, Z.

PY - 2003/9/1

Y1 - 2003/9/1

N2 - The prompt γ-activation analysis (PGAA) facility at Budapest Research Reactor offers a unique possibility to perform in-beam measurements. Several k0 factors for decay γ-lines of short-lived nuclides have been determined accurately by means of in-beam activation. The present values compare well with literature data. New k0 factors are proposed for 24mNa and 60mCo.

AB - The prompt γ-activation analysis (PGAA) facility at Budapest Research Reactor offers a unique possibility to perform in-beam measurements. Several k0 factors for decay γ-lines of short-lived nuclides have been determined accurately by means of in-beam activation. The present values compare well with literature data. New k0 factors are proposed for 24mNa and 60mCo.

UR - http://www.scopus.com/inward/record.url?scp=0141747233&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0141747233&partnerID=8YFLogxK

U2 - 10.1023/A:1025440631733

DO - 10.1023/A:1025440631733

M3 - Article

VL - 257

SP - 561

EP - 564

JO - Journal of Radioanalytical and Nuclear Chemistry

JF - Journal of Radioanalytical and Nuclear Chemistry

SN - 0022-4081

IS - 3

ER -