Improved potentiometric SECM imaging of galvanic corrosion reactions

D. Filotás, B. M. Fernández-Pérez, J. Izquierdo, A. Kiss, L. Nagy, G. Nagy, R. M. Souto

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

The galvanic corrosion of Zn-Cu systems has been monitored in situ using scanning electrochemical microscopy in the potentiometric mode. Here, the initial studies performed using double-barrel microelectrodes for the simultaneous detection of local pH and Zn ion concentration changes in single lines scans, have been extended to the obtention of 2-D maps of Cu2+ and Zn2+ ions. The construction and calibration of a novel Cu2+ ion selective microelectrode is reported. New scanning algorithms and data evaluation tools have been explored for faster acquisition rates than those limited by the time constants associated to potentiometric response.

Original languageEnglish
Pages (from-to)136-145
Number of pages10
JournalCorrosion Science
Volume129
DOIs
Publication statusPublished - Dec 1 2017

Fingerprint

Microelectrodes
Ions
Corrosion
Imaging techniques
Scanning
Microscopic examination
Calibration

Keywords

  • A. Copper
  • A. Zinc
  • B. Ion selective microelectrode
  • B. Scanning electrochemical microscopy
  • C. Galvanic corrosion
  • C. Local pH distribution

ASJC Scopus subject areas

  • Chemistry(all)
  • Chemical Engineering(all)
  • Materials Science(all)

Cite this

Filotás, D., Fernández-Pérez, B. M., Izquierdo, J., Kiss, A., Nagy, L., Nagy, G., & Souto, R. M. (2017). Improved potentiometric SECM imaging of galvanic corrosion reactions. Corrosion Science, 129, 136-145. https://doi.org/10.1016/j.corsci.2017.10.006

Improved potentiometric SECM imaging of galvanic corrosion reactions. / Filotás, D.; Fernández-Pérez, B. M.; Izquierdo, J.; Kiss, A.; Nagy, L.; Nagy, G.; Souto, R. M.

In: Corrosion Science, Vol. 129, 01.12.2017, p. 136-145.

Research output: Contribution to journalArticle

Filotás, D, Fernández-Pérez, BM, Izquierdo, J, Kiss, A, Nagy, L, Nagy, G & Souto, RM 2017, 'Improved potentiometric SECM imaging of galvanic corrosion reactions', Corrosion Science, vol. 129, pp. 136-145. https://doi.org/10.1016/j.corsci.2017.10.006
Filotás D, Fernández-Pérez BM, Izquierdo J, Kiss A, Nagy L, Nagy G et al. Improved potentiometric SECM imaging of galvanic corrosion reactions. Corrosion Science. 2017 Dec 1;129:136-145. https://doi.org/10.1016/j.corsci.2017.10.006
Filotás, D. ; Fernández-Pérez, B. M. ; Izquierdo, J. ; Kiss, A. ; Nagy, L. ; Nagy, G. ; Souto, R. M. / Improved potentiometric SECM imaging of galvanic corrosion reactions. In: Corrosion Science. 2017 ; Vol. 129. pp. 136-145.
@article{3ff068873c5747eb82e439088dd14607,
title = "Improved potentiometric SECM imaging of galvanic corrosion reactions",
abstract = "The galvanic corrosion of Zn-Cu systems has been monitored in situ using scanning electrochemical microscopy in the potentiometric mode. Here, the initial studies performed using double-barrel microelectrodes for the simultaneous detection of local pH and Zn ion concentration changes in single lines scans, have been extended to the obtention of 2-D maps of Cu2+ and Zn2+ ions. The construction and calibration of a novel Cu2+ ion selective microelectrode is reported. New scanning algorithms and data evaluation tools have been explored for faster acquisition rates than those limited by the time constants associated to potentiometric response.",
keywords = "A. Copper, A. Zinc, B. Ion selective microelectrode, B. Scanning electrochemical microscopy, C. Galvanic corrosion, C. Local pH distribution",
author = "D. Filot{\'a}s and Fern{\'a}ndez-P{\'e}rez, {B. M.} and J. Izquierdo and A. Kiss and L. Nagy and G. Nagy and Souto, {R. M.}",
year = "2017",
month = "12",
day = "1",
doi = "10.1016/j.corsci.2017.10.006",
language = "English",
volume = "129",
pages = "136--145",
journal = "Corrosion Science",
issn = "0010-938X",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Improved potentiometric SECM imaging of galvanic corrosion reactions

AU - Filotás, D.

AU - Fernández-Pérez, B. M.

AU - Izquierdo, J.

AU - Kiss, A.

AU - Nagy, L.

AU - Nagy, G.

AU - Souto, R. M.

PY - 2017/12/1

Y1 - 2017/12/1

N2 - The galvanic corrosion of Zn-Cu systems has been monitored in situ using scanning electrochemical microscopy in the potentiometric mode. Here, the initial studies performed using double-barrel microelectrodes for the simultaneous detection of local pH and Zn ion concentration changes in single lines scans, have been extended to the obtention of 2-D maps of Cu2+ and Zn2+ ions. The construction and calibration of a novel Cu2+ ion selective microelectrode is reported. New scanning algorithms and data evaluation tools have been explored for faster acquisition rates than those limited by the time constants associated to potentiometric response.

AB - The galvanic corrosion of Zn-Cu systems has been monitored in situ using scanning electrochemical microscopy in the potentiometric mode. Here, the initial studies performed using double-barrel microelectrodes for the simultaneous detection of local pH and Zn ion concentration changes in single lines scans, have been extended to the obtention of 2-D maps of Cu2+ and Zn2+ ions. The construction and calibration of a novel Cu2+ ion selective microelectrode is reported. New scanning algorithms and data evaluation tools have been explored for faster acquisition rates than those limited by the time constants associated to potentiometric response.

KW - A. Copper

KW - A. Zinc

KW - B. Ion selective microelectrode

KW - B. Scanning electrochemical microscopy

KW - C. Galvanic corrosion

KW - C. Local pH distribution

UR - http://www.scopus.com/inward/record.url?scp=85031686613&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85031686613&partnerID=8YFLogxK

U2 - 10.1016/j.corsci.2017.10.006

DO - 10.1016/j.corsci.2017.10.006

M3 - Article

AN - SCOPUS:85031686613

VL - 129

SP - 136

EP - 145

JO - Corrosion Science

JF - Corrosion Science

SN - 0010-938X

ER -