Impact of a physiological medium on the aggregation state of C60 and C70 fullerenes

E. A. Kyzyma, M. O. Kuzmenko, L. A. Bulavin, V. I. Petrenko, I. V. Mikheev, M. A. Zabolotnyi, M. Kubovcikova, P. Kopcansky, M. V. Korobov, M. V. Avdeev, V. Aksenov

Research output: Contribution to journalArticle

Abstract

The C60 and C70 fullerene-cluster size distribution in aqueous solutions and a physiological medium is studied via dynamic light scattering. The initial aqueous solutions of fullerenes obtained via different methods are found to contain clusters with a characteristic size of about 100 nm. The additional aggregation of fullerenes is observed after their transfer into a physiological medium (0.9% NaCl) and is established to depend on the preparation method. The cluster-size distribution in a fullerene–pectic-acid mixture is found to vary in water and a physiological medium. The results reveal the need for additional studies of the structure and properties of C60 and C70 molecules, as well as their complexes with medicines, in a physiological medium for medical applications.

Original languageEnglish
Pages (from-to)1125-1128
Number of pages4
JournalJournal of Surface Investigation
Volume10
Issue number6
DOIs
Publication statusPublished - Nov 1 2016

Fingerprint

Fullerenes
Agglomeration
Medical applications
Dynamic light scattering
Medicine
Molecules
Acids
Water
fullerene C70
fullerene C60

Keywords

  • dynamic light scattering
  • fullerenes
  • physiological medium

ASJC Scopus subject areas

  • Surfaces, Coatings and Films

Cite this

Kyzyma, E. A., Kuzmenko, M. O., Bulavin, L. A., Petrenko, V. I., Mikheev, I. V., Zabolotnyi, M. A., ... Aksenov, V. (2016). Impact of a physiological medium on the aggregation state of C60 and C70 fullerenes. Journal of Surface Investigation, 10(6), 1125-1128. https://doi.org/10.1134/S1027451016050517

Impact of a physiological medium on the aggregation state of C60 and C70 fullerenes. / Kyzyma, E. A.; Kuzmenko, M. O.; Bulavin, L. A.; Petrenko, V. I.; Mikheev, I. V.; Zabolotnyi, M. A.; Kubovcikova, M.; Kopcansky, P.; Korobov, M. V.; Avdeev, M. V.; Aksenov, V.

In: Journal of Surface Investigation, Vol. 10, No. 6, 01.11.2016, p. 1125-1128.

Research output: Contribution to journalArticle

Kyzyma, EA, Kuzmenko, MO, Bulavin, LA, Petrenko, VI, Mikheev, IV, Zabolotnyi, MA, Kubovcikova, M, Kopcansky, P, Korobov, MV, Avdeev, MV & Aksenov, V 2016, 'Impact of a physiological medium on the aggregation state of C60 and C70 fullerenes', Journal of Surface Investigation, vol. 10, no. 6, pp. 1125-1128. https://doi.org/10.1134/S1027451016050517
Kyzyma EA, Kuzmenko MO, Bulavin LA, Petrenko VI, Mikheev IV, Zabolotnyi MA et al. Impact of a physiological medium on the aggregation state of C60 and C70 fullerenes. Journal of Surface Investigation. 2016 Nov 1;10(6):1125-1128. https://doi.org/10.1134/S1027451016050517
Kyzyma, E. A. ; Kuzmenko, M. O. ; Bulavin, L. A. ; Petrenko, V. I. ; Mikheev, I. V. ; Zabolotnyi, M. A. ; Kubovcikova, M. ; Kopcansky, P. ; Korobov, M. V. ; Avdeev, M. V. ; Aksenov, V. / Impact of a physiological medium on the aggregation state of C60 and C70 fullerenes. In: Journal of Surface Investigation. 2016 ; Vol. 10, No. 6. pp. 1125-1128.
@article{7fd7a5b0939444b79344ed558ada754e,
title = "Impact of a physiological medium on the aggregation state of C60 and C70 fullerenes",
abstract = "The C60 and C70 fullerene-cluster size distribution in aqueous solutions and a physiological medium is studied via dynamic light scattering. The initial aqueous solutions of fullerenes obtained via different methods are found to contain clusters with a characteristic size of about 100 nm. The additional aggregation of fullerenes is observed after their transfer into a physiological medium (0.9{\%} NaCl) and is established to depend on the preparation method. The cluster-size distribution in a fullerene–pectic-acid mixture is found to vary in water and a physiological medium. The results reveal the need for additional studies of the structure and properties of C60 and C70 molecules, as well as their complexes with medicines, in a physiological medium for medical applications.",
keywords = "dynamic light scattering, fullerenes, physiological medium",
author = "Kyzyma, {E. A.} and Kuzmenko, {M. O.} and Bulavin, {L. A.} and Petrenko, {V. I.} and Mikheev, {I. V.} and Zabolotnyi, {M. A.} and M. Kubovcikova and P. Kopcansky and Korobov, {M. V.} and Avdeev, {M. V.} and V. Aksenov",
year = "2016",
month = "11",
day = "1",
doi = "10.1134/S1027451016050517",
language = "English",
volume = "10",
pages = "1125--1128",
journal = "Journal of Surface Investigation",
issn = "1027-4510",
publisher = "Maik Nauka-Interperiodica Publishing",
number = "6",

}

TY - JOUR

T1 - Impact of a physiological medium on the aggregation state of C60 and C70 fullerenes

AU - Kyzyma, E. A.

AU - Kuzmenko, M. O.

AU - Bulavin, L. A.

AU - Petrenko, V. I.

AU - Mikheev, I. V.

AU - Zabolotnyi, M. A.

AU - Kubovcikova, M.

AU - Kopcansky, P.

AU - Korobov, M. V.

AU - Avdeev, M. V.

AU - Aksenov, V.

PY - 2016/11/1

Y1 - 2016/11/1

N2 - The C60 and C70 fullerene-cluster size distribution in aqueous solutions and a physiological medium is studied via dynamic light scattering. The initial aqueous solutions of fullerenes obtained via different methods are found to contain clusters with a characteristic size of about 100 nm. The additional aggregation of fullerenes is observed after their transfer into a physiological medium (0.9% NaCl) and is established to depend on the preparation method. The cluster-size distribution in a fullerene–pectic-acid mixture is found to vary in water and a physiological medium. The results reveal the need for additional studies of the structure and properties of C60 and C70 molecules, as well as their complexes with medicines, in a physiological medium for medical applications.

AB - The C60 and C70 fullerene-cluster size distribution in aqueous solutions and a physiological medium is studied via dynamic light scattering. The initial aqueous solutions of fullerenes obtained via different methods are found to contain clusters with a characteristic size of about 100 nm. The additional aggregation of fullerenes is observed after their transfer into a physiological medium (0.9% NaCl) and is established to depend on the preparation method. The cluster-size distribution in a fullerene–pectic-acid mixture is found to vary in water and a physiological medium. The results reveal the need for additional studies of the structure and properties of C60 and C70 molecules, as well as their complexes with medicines, in a physiological medium for medical applications.

KW - dynamic light scattering

KW - fullerenes

KW - physiological medium

UR - http://www.scopus.com/inward/record.url?scp=85002062809&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85002062809&partnerID=8YFLogxK

U2 - 10.1134/S1027451016050517

DO - 10.1134/S1027451016050517

M3 - Article

AN - SCOPUS:85002062809

VL - 10

SP - 1125

EP - 1128

JO - Journal of Surface Investigation

JF - Journal of Surface Investigation

SN - 1027-4510

IS - 6

ER -