Image quality of the temporal bone window examined by transcranial doppler sonography and correlation with postmortem computed tomography measurements

J. Kollár, Gernot Schulte-Altedorneburg, Judit Sikula, B. Fülesdi, E. Bernd Ringelstein, Vineet Mehta, L. Csiba, Dirk W. Droste

Research output: Contribution to journalArticle

36 Citations (Scopus)

Abstract

Background and Purpose: The major limitation of native transcranial colour-coded duplex sonography (TCCS) in older stroke patients is the relatively frequent occurrence of an insufficient temporal window. Our goal was to investigate the relationship between the in vivo Doppler ultrasound image quality of the temporal bone, and computed tomography (CT)-determined thickness, density, and homogeneity of cadaver temporal bone. Methods: Thirty-three moribund neurological patients who eventually died were examined by TCCS using the transtemporal approach. The sonographer categorized the quality of the TCCS image (excellent, intermediate, and poor). During autopsy, a rectangular sample of the temporal squama was removed, which corresponded to the area of the in vivo acoustic window. The thickness of the whole temporal bone, cortical, and cancellous (= diploe) bone as well as the density and homogeneity were determined by high-resolution CT. Results: Thirty-seven temporal bones were obtained. The quality of the acoustic window was classified as excellent in 13, intermediate in 6 and poor in 18 cases. A significant correlation between the complete bone thickness, as well as between the absolute thickness of the diploe and the quality of the acoustic window was found: the thinner the bone/diploe, the better the colour Doppler signal. The thickness of the cortical plates and the homogeneity of the bones were identical in the three image quality categories. Conclusion: The transtemporal TCCS image quality depends mainly on the thickness of the cancellous component of the temporal bone.

Original languageEnglish
Pages (from-to)61-65
Number of pages5
JournalCerebrovascular Diseases
Volume17
Issue number1
DOIs
Publication statusPublished - 2004

Fingerprint

Doppler Transcranial Ultrasonography
Temporal Bone
Color
Tomography
Ultrasonography
Acoustics
Bone and Bones
Doppler Ultrasonography
Cadaver
Cerebral Cortex
Autopsy
Stroke

Keywords

  • Acoustic window
  • Temporal bone computed tomography densitometry
  • Transcranial colour-coded duplex sonography

ASJC Scopus subject areas

  • Clinical Neurology

Cite this

Image quality of the temporal bone window examined by transcranial doppler sonography and correlation with postmortem computed tomography measurements. / Kollár, J.; Schulte-Altedorneburg, Gernot; Sikula, Judit; Fülesdi, B.; Ringelstein, E. Bernd; Mehta, Vineet; Csiba, L.; Droste, Dirk W.

In: Cerebrovascular Diseases, Vol. 17, No. 1, 2004, p. 61-65.

Research output: Contribution to journalArticle

Kollár, J. ; Schulte-Altedorneburg, Gernot ; Sikula, Judit ; Fülesdi, B. ; Ringelstein, E. Bernd ; Mehta, Vineet ; Csiba, L. ; Droste, Dirk W. / Image quality of the temporal bone window examined by transcranial doppler sonography and correlation with postmortem computed tomography measurements. In: Cerebrovascular Diseases. 2004 ; Vol. 17, No. 1. pp. 61-65.
@article{3069bc6c414d4d3996a8ec018c84bbe2,
title = "Image quality of the temporal bone window examined by transcranial doppler sonography and correlation with postmortem computed tomography measurements",
abstract = "Background and Purpose: The major limitation of native transcranial colour-coded duplex sonography (TCCS) in older stroke patients is the relatively frequent occurrence of an insufficient temporal window. Our goal was to investigate the relationship between the in vivo Doppler ultrasound image quality of the temporal bone, and computed tomography (CT)-determined thickness, density, and homogeneity of cadaver temporal bone. Methods: Thirty-three moribund neurological patients who eventually died were examined by TCCS using the transtemporal approach. The sonographer categorized the quality of the TCCS image (excellent, intermediate, and poor). During autopsy, a rectangular sample of the temporal squama was removed, which corresponded to the area of the in vivo acoustic window. The thickness of the whole temporal bone, cortical, and cancellous (= diploe) bone as well as the density and homogeneity were determined by high-resolution CT. Results: Thirty-seven temporal bones were obtained. The quality of the acoustic window was classified as excellent in 13, intermediate in 6 and poor in 18 cases. A significant correlation between the complete bone thickness, as well as between the absolute thickness of the diploe and the quality of the acoustic window was found: the thinner the bone/diploe, the better the colour Doppler signal. The thickness of the cortical plates and the homogeneity of the bones were identical in the three image quality categories. Conclusion: The transtemporal TCCS image quality depends mainly on the thickness of the cancellous component of the temporal bone.",
keywords = "Acoustic window, Temporal bone computed tomography densitometry, Transcranial colour-coded duplex sonography",
author = "J. Koll{\'a}r and Gernot Schulte-Altedorneburg and Judit Sikula and B. F{\"u}lesdi and Ringelstein, {E. Bernd} and Vineet Mehta and L. Csiba and Droste, {Dirk W.}",
year = "2004",
doi = "10.1159/000073899",
language = "English",
volume = "17",
pages = "61--65",
journal = "Cerebrovascular Diseases",
issn = "1015-9770",
publisher = "S. Karger AG",
number = "1",

}

TY - JOUR

T1 - Image quality of the temporal bone window examined by transcranial doppler sonography and correlation with postmortem computed tomography measurements

AU - Kollár, J.

AU - Schulte-Altedorneburg, Gernot

AU - Sikula, Judit

AU - Fülesdi, B.

AU - Ringelstein, E. Bernd

AU - Mehta, Vineet

AU - Csiba, L.

AU - Droste, Dirk W.

PY - 2004

Y1 - 2004

N2 - Background and Purpose: The major limitation of native transcranial colour-coded duplex sonography (TCCS) in older stroke patients is the relatively frequent occurrence of an insufficient temporal window. Our goal was to investigate the relationship between the in vivo Doppler ultrasound image quality of the temporal bone, and computed tomography (CT)-determined thickness, density, and homogeneity of cadaver temporal bone. Methods: Thirty-three moribund neurological patients who eventually died were examined by TCCS using the transtemporal approach. The sonographer categorized the quality of the TCCS image (excellent, intermediate, and poor). During autopsy, a rectangular sample of the temporal squama was removed, which corresponded to the area of the in vivo acoustic window. The thickness of the whole temporal bone, cortical, and cancellous (= diploe) bone as well as the density and homogeneity were determined by high-resolution CT. Results: Thirty-seven temporal bones were obtained. The quality of the acoustic window was classified as excellent in 13, intermediate in 6 and poor in 18 cases. A significant correlation between the complete bone thickness, as well as between the absolute thickness of the diploe and the quality of the acoustic window was found: the thinner the bone/diploe, the better the colour Doppler signal. The thickness of the cortical plates and the homogeneity of the bones were identical in the three image quality categories. Conclusion: The transtemporal TCCS image quality depends mainly on the thickness of the cancellous component of the temporal bone.

AB - Background and Purpose: The major limitation of native transcranial colour-coded duplex sonography (TCCS) in older stroke patients is the relatively frequent occurrence of an insufficient temporal window. Our goal was to investigate the relationship between the in vivo Doppler ultrasound image quality of the temporal bone, and computed tomography (CT)-determined thickness, density, and homogeneity of cadaver temporal bone. Methods: Thirty-three moribund neurological patients who eventually died were examined by TCCS using the transtemporal approach. The sonographer categorized the quality of the TCCS image (excellent, intermediate, and poor). During autopsy, a rectangular sample of the temporal squama was removed, which corresponded to the area of the in vivo acoustic window. The thickness of the whole temporal bone, cortical, and cancellous (= diploe) bone as well as the density and homogeneity were determined by high-resolution CT. Results: Thirty-seven temporal bones were obtained. The quality of the acoustic window was classified as excellent in 13, intermediate in 6 and poor in 18 cases. A significant correlation between the complete bone thickness, as well as between the absolute thickness of the diploe and the quality of the acoustic window was found: the thinner the bone/diploe, the better the colour Doppler signal. The thickness of the cortical plates and the homogeneity of the bones were identical in the three image quality categories. Conclusion: The transtemporal TCCS image quality depends mainly on the thickness of the cancellous component of the temporal bone.

KW - Acoustic window

KW - Temporal bone computed tomography densitometry

KW - Transcranial colour-coded duplex sonography

UR - http://www.scopus.com/inward/record.url?scp=0742271307&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0742271307&partnerID=8YFLogxK

U2 - 10.1159/000073899

DO - 10.1159/000073899

M3 - Article

C2 - 14530639

AN - SCOPUS:0742271307

VL - 17

SP - 61

EP - 65

JO - Cerebrovascular Diseases

JF - Cerebrovascular Diseases

SN - 1015-9770

IS - 1

ER -