Hypobaric hypoxia reduces the amplitude of oscillatory potentials in the human ERG

Márta Janáky, Andor Grósz, Erika Tóth, K. Benedek, G. Benedek

Research output: Contribution to journalArticle

21 Citations (Scopus)

Abstract

Purpose: To explore the retinal functions in healthy volunteers during acute hypoxic exposure, applying a set of electrophysiological tests. Methods: Standard electroretinograms (ERGs) of the retina (rod-(scotopic) ERGs, cone-(photopic) ERGs, maximal responses and oscillatory potentials (OPs)) and 30-Hz flicker ERGs were recorded according to ISCEV (International Society of Clinical Electrophysiology of Vision) recommendations in 14 healthy volunteers during a 15-min exposure to a simulated altitude of 5500 m. Results: The mean arterial oxygen saturation level was significantly reduced (P <0.001) during the hypobaric challenge. It returned to the normal level very shortly after the end of the hypoxic exposure. No significant change in the latency or amplitude of the slow components of the ERG was found in any recording. The OPs of the ERG, however, revealed a significant decrease in amplitude during hypoxic exposure. Both OP1 and OP2 amplitudes were significantly different (P <0.05) from the baseline values during hypoxia. Partial recovery of these waves occurred after termination of the hypoxia. Conclusions: These results appear to support the notion that the inner layers of the retina presumed to be the main source of the OPs, display the highest sensitivity towards circulatory and/or hypoxic challenges.

Original languageEnglish
Pages (from-to)45-51
Number of pages7
JournalDocumenta Ophthalmologica
Volume114
Issue number1
DOIs
Publication statusPublished - Jan 2007

Fingerprint

Healthy Volunteers
Retinal Rod Photoreceptor Cells
Electrophysiology
Retina
Oxygen
Hypoxia

Keywords

  • Electrophysiology
  • ERG
  • Human
  • Hypoxia
  • Oscillatory potentials

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Hypobaric hypoxia reduces the amplitude of oscillatory potentials in the human ERG. / Janáky, Márta; Grósz, Andor; Tóth, Erika; Benedek, K.; Benedek, G.

In: Documenta Ophthalmologica, Vol. 114, No. 1, 01.2007, p. 45-51.

Research output: Contribution to journalArticle

Janáky, Márta ; Grósz, Andor ; Tóth, Erika ; Benedek, K. ; Benedek, G. / Hypobaric hypoxia reduces the amplitude of oscillatory potentials in the human ERG. In: Documenta Ophthalmologica. 2007 ; Vol. 114, No. 1. pp. 45-51.
@article{b0be5bc5b05444bca4ee52c6e2881a93,
title = "Hypobaric hypoxia reduces the amplitude of oscillatory potentials in the human ERG",
abstract = "Purpose: To explore the retinal functions in healthy volunteers during acute hypoxic exposure, applying a set of electrophysiological tests. Methods: Standard electroretinograms (ERGs) of the retina (rod-(scotopic) ERGs, cone-(photopic) ERGs, maximal responses and oscillatory potentials (OPs)) and 30-Hz flicker ERGs were recorded according to ISCEV (International Society of Clinical Electrophysiology of Vision) recommendations in 14 healthy volunteers during a 15-min exposure to a simulated altitude of 5500 m. Results: The mean arterial oxygen saturation level was significantly reduced (P <0.001) during the hypobaric challenge. It returned to the normal level very shortly after the end of the hypoxic exposure. No significant change in the latency or amplitude of the slow components of the ERG was found in any recording. The OPs of the ERG, however, revealed a significant decrease in amplitude during hypoxic exposure. Both OP1 and OP2 amplitudes were significantly different (P <0.05) from the baseline values during hypoxia. Partial recovery of these waves occurred after termination of the hypoxia. Conclusions: These results appear to support the notion that the inner layers of the retina presumed to be the main source of the OPs, display the highest sensitivity towards circulatory and/or hypoxic challenges.",
keywords = "Electrophysiology, ERG, Human, Hypoxia, Oscillatory potentials",
author = "M{\'a}rta Jan{\'a}ky and Andor Gr{\'o}sz and Erika T{\'o}th and K. Benedek and G. Benedek",
year = "2007",
month = "1",
doi = "10.1007/s10633-006-9038-5",
language = "English",
volume = "114",
pages = "45--51",
journal = "Documenta Ophthalmologica",
issn = "0012-4486",
publisher = "Springer Netherlands",
number = "1",

}

TY - JOUR

T1 - Hypobaric hypoxia reduces the amplitude of oscillatory potentials in the human ERG

AU - Janáky, Márta

AU - Grósz, Andor

AU - Tóth, Erika

AU - Benedek, K.

AU - Benedek, G.

PY - 2007/1

Y1 - 2007/1

N2 - Purpose: To explore the retinal functions in healthy volunteers during acute hypoxic exposure, applying a set of electrophysiological tests. Methods: Standard electroretinograms (ERGs) of the retina (rod-(scotopic) ERGs, cone-(photopic) ERGs, maximal responses and oscillatory potentials (OPs)) and 30-Hz flicker ERGs were recorded according to ISCEV (International Society of Clinical Electrophysiology of Vision) recommendations in 14 healthy volunteers during a 15-min exposure to a simulated altitude of 5500 m. Results: The mean arterial oxygen saturation level was significantly reduced (P <0.001) during the hypobaric challenge. It returned to the normal level very shortly after the end of the hypoxic exposure. No significant change in the latency or amplitude of the slow components of the ERG was found in any recording. The OPs of the ERG, however, revealed a significant decrease in amplitude during hypoxic exposure. Both OP1 and OP2 amplitudes were significantly different (P <0.05) from the baseline values during hypoxia. Partial recovery of these waves occurred after termination of the hypoxia. Conclusions: These results appear to support the notion that the inner layers of the retina presumed to be the main source of the OPs, display the highest sensitivity towards circulatory and/or hypoxic challenges.

AB - Purpose: To explore the retinal functions in healthy volunteers during acute hypoxic exposure, applying a set of electrophysiological tests. Methods: Standard electroretinograms (ERGs) of the retina (rod-(scotopic) ERGs, cone-(photopic) ERGs, maximal responses and oscillatory potentials (OPs)) and 30-Hz flicker ERGs were recorded according to ISCEV (International Society of Clinical Electrophysiology of Vision) recommendations in 14 healthy volunteers during a 15-min exposure to a simulated altitude of 5500 m. Results: The mean arterial oxygen saturation level was significantly reduced (P <0.001) during the hypobaric challenge. It returned to the normal level very shortly after the end of the hypoxic exposure. No significant change in the latency or amplitude of the slow components of the ERG was found in any recording. The OPs of the ERG, however, revealed a significant decrease in amplitude during hypoxic exposure. Both OP1 and OP2 amplitudes were significantly different (P <0.05) from the baseline values during hypoxia. Partial recovery of these waves occurred after termination of the hypoxia. Conclusions: These results appear to support the notion that the inner layers of the retina presumed to be the main source of the OPs, display the highest sensitivity towards circulatory and/or hypoxic challenges.

KW - Electrophysiology

KW - ERG

KW - Human

KW - Hypoxia

KW - Oscillatory potentials

UR - http://www.scopus.com/inward/record.url?scp=33846799216&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33846799216&partnerID=8YFLogxK

U2 - 10.1007/s10633-006-9038-5

DO - 10.1007/s10633-006-9038-5

M3 - Article

VL - 114

SP - 45

EP - 51

JO - Documenta Ophthalmologica

JF - Documenta Ophthalmologica

SN - 0012-4486

IS - 1

ER -