High-performance liquid chromatographic enantioseparation of unusual isoxazoline-fused 2-aminocyclopentanecarboxylic acids on macrocyclic glycopeptide-based chiral stationary phases

László Sipos, I. Ilisz, Melinda Nonn, F. Fülöp, Zoltán Pataj, Daniel W. Armstrong, A. Péter

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

The enantiomers of four unusual isoxazoline-fused 2-aminocyclopentanecarboxylic acids were directly separated on chiral stationary phases containing macrocyclic glycopeptide antibiotics teicoplanin (Astec Chirobiotic T and T2), teicoplanin aglycone (Chirobiotic TAG), vancomycin (Chirobiotic V) and vancomycin aglycone (Chirobiotic VAG) as chiral selectors. The effects of the mobile phase composition, the structure of the analytes and temperature on the separations were investigated. Experiments were performed at constant mobile phase compositions in the temperature range 5-45 °C to study the effects of temperature, and thermodynamic parameters were calculated from plots of ln. k or ln α versus 1/ T. Some mechanistic aspects of the chiral recognition process are discussed with respect to the structures of the analytes. It was found that the enantiomeric separations were in most cases enthalpy-driven. The sequence of elution of the enantiomers was determined in all cases.

Original languageEnglish
Pages (from-to)142-151
Number of pages10
JournalJournal of Chromatography A
Volume1232
DOIs
Publication statusPublished - Apr 6 2012

Fingerprint

Cycloleucine
Glycopeptides
Enantiomers
Vancomycin
Phase composition
Temperature
Liquids
Teicoplanin
Thermodynamics
Enthalpy
Anti-Bacterial Agents
Experiments

Keywords

  • Chirobiotic columns
  • Column liquid chromatography
  • Isoxazoline-fused 2-aminocyclopentanecarboxylic acids
  • Macrocyclic glycopeptide-based chiral stationary phases

ASJC Scopus subject areas

  • Analytical Chemistry
  • Organic Chemistry
  • Biochemistry

Cite this

High-performance liquid chromatographic enantioseparation of unusual isoxazoline-fused 2-aminocyclopentanecarboxylic acids on macrocyclic glycopeptide-based chiral stationary phases. / Sipos, László; Ilisz, I.; Nonn, Melinda; Fülöp, F.; Pataj, Zoltán; Armstrong, Daniel W.; Péter, A.

In: Journal of Chromatography A, Vol. 1232, 06.04.2012, p. 142-151.

Research output: Contribution to journalArticle

@article{d756678c602340ed8bd7c8a1fd8e4261,
title = "High-performance liquid chromatographic enantioseparation of unusual isoxazoline-fused 2-aminocyclopentanecarboxylic acids on macrocyclic glycopeptide-based chiral stationary phases",
abstract = "The enantiomers of four unusual isoxazoline-fused 2-aminocyclopentanecarboxylic acids were directly separated on chiral stationary phases containing macrocyclic glycopeptide antibiotics teicoplanin (Astec Chirobiotic T and T2), teicoplanin aglycone (Chirobiotic TAG), vancomycin (Chirobiotic V) and vancomycin aglycone (Chirobiotic VAG) as chiral selectors. The effects of the mobile phase composition, the structure of the analytes and temperature on the separations were investigated. Experiments were performed at constant mobile phase compositions in the temperature range 5-45 °C to study the effects of temperature, and thermodynamic parameters were calculated from plots of ln. k or ln α versus 1/ T. Some mechanistic aspects of the chiral recognition process are discussed with respect to the structures of the analytes. It was found that the enantiomeric separations were in most cases enthalpy-driven. The sequence of elution of the enantiomers was determined in all cases.",
keywords = "Chirobiotic columns, Column liquid chromatography, Isoxazoline-fused 2-aminocyclopentanecarboxylic acids, Macrocyclic glycopeptide-based chiral stationary phases",
author = "L{\'a}szl{\'o} Sipos and I. Ilisz and Melinda Nonn and F. F{\"u}l{\"o}p and Zolt{\'a}n Pataj and Armstrong, {Daniel W.} and A. P{\'e}ter",
year = "2012",
month = "4",
day = "6",
doi = "10.1016/j.chroma.2011.11.027",
language = "English",
volume = "1232",
pages = "142--151",
journal = "Journal of Chromatography",
issn = "0021-9673",
publisher = "Elsevier",

}

TY - JOUR

T1 - High-performance liquid chromatographic enantioseparation of unusual isoxazoline-fused 2-aminocyclopentanecarboxylic acids on macrocyclic glycopeptide-based chiral stationary phases

AU - Sipos, László

AU - Ilisz, I.

AU - Nonn, Melinda

AU - Fülöp, F.

AU - Pataj, Zoltán

AU - Armstrong, Daniel W.

AU - Péter, A.

PY - 2012/4/6

Y1 - 2012/4/6

N2 - The enantiomers of four unusual isoxazoline-fused 2-aminocyclopentanecarboxylic acids were directly separated on chiral stationary phases containing macrocyclic glycopeptide antibiotics teicoplanin (Astec Chirobiotic T and T2), teicoplanin aglycone (Chirobiotic TAG), vancomycin (Chirobiotic V) and vancomycin aglycone (Chirobiotic VAG) as chiral selectors. The effects of the mobile phase composition, the structure of the analytes and temperature on the separations were investigated. Experiments were performed at constant mobile phase compositions in the temperature range 5-45 °C to study the effects of temperature, and thermodynamic parameters were calculated from plots of ln. k or ln α versus 1/ T. Some mechanistic aspects of the chiral recognition process are discussed with respect to the structures of the analytes. It was found that the enantiomeric separations were in most cases enthalpy-driven. The sequence of elution of the enantiomers was determined in all cases.

AB - The enantiomers of four unusual isoxazoline-fused 2-aminocyclopentanecarboxylic acids were directly separated on chiral stationary phases containing macrocyclic glycopeptide antibiotics teicoplanin (Astec Chirobiotic T and T2), teicoplanin aglycone (Chirobiotic TAG), vancomycin (Chirobiotic V) and vancomycin aglycone (Chirobiotic VAG) as chiral selectors. The effects of the mobile phase composition, the structure of the analytes and temperature on the separations were investigated. Experiments were performed at constant mobile phase compositions in the temperature range 5-45 °C to study the effects of temperature, and thermodynamic parameters were calculated from plots of ln. k or ln α versus 1/ T. Some mechanistic aspects of the chiral recognition process are discussed with respect to the structures of the analytes. It was found that the enantiomeric separations were in most cases enthalpy-driven. The sequence of elution of the enantiomers was determined in all cases.

KW - Chirobiotic columns

KW - Column liquid chromatography

KW - Isoxazoline-fused 2-aminocyclopentanecarboxylic acids

KW - Macrocyclic glycopeptide-based chiral stationary phases

UR - http://www.scopus.com/inward/record.url?scp=84858075154&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84858075154&partnerID=8YFLogxK

U2 - 10.1016/j.chroma.2011.11.027

DO - 10.1016/j.chroma.2011.11.027

M3 - Article

C2 - 22177724

AN - SCOPUS:84858075154

VL - 1232

SP - 142

EP - 151

JO - Journal of Chromatography

JF - Journal of Chromatography

SN - 0021-9673

ER -