Abstract
Objective: To describe the standardization process and reliability of anthropometric and bioelectrical impedance analysis (BIA) measurements. We examined both intra- and interobserver errors for skinfolds, circumferences and BIA. Methods: For the intraobserver error assessment, first of all, 202 adolescents in the pilot study (110 boys, 92 girls, aged 13.64±0.78 years) were assessed. For the second intraobserver and interobserver assessments, 10 adolescents were studied (5 boys and 5 girls). Results: The pilot study's intraobserver technical errors of measurement (TEMs) were between 0.12 and 2.9 mm for skinfold thicknesses, and between 0.13 and 1.75 cm for circumferences. Intraobserver reliability for skinfold thicknesses was greater than 69.44% and beyond 78.43% for circumferences. The final workshop's intraobserver TEMs for skinfold thicknesses and circumferences were smaller than 1; for BIA resistance TEMs were smaller than 0.1 Ω and for reactance they were smaller than 0.2 Ω. Intraobserver reliability values were greater than 95, 97, 99 and 97% for skinfold thicknesses, circumferences, BIA resistance and reactance, respectively. Interobserver TEMs for skinfold thicknesses and circumferences ranged from 1 to 2 mm; for BIA they were 1.16 and 1.26 Ω for resistance and reactance, respectively. Interobserver reliability for skinfold thicknesses and circumferences were greater than 90%, and for BIA resistance and reactance they were greater than 90%. Conclusions: After the results of the pilot study, it was necessary to optimize the quality of the anthropometric measurements before the final survey. Significant improvements were observed in the intraobserver reliabilities for all measurements, with interobserver reliabilities being higher than 90% for most of the measurements.The Healthy Lifestyle in Europe by Nutrition in Adolescence Study aims to describe total body fat percentage and anthropometric indices of body fat distribution in European adolescents.
Original language | English |
---|---|
Journal | International Journal of Obesity |
Volume | 32 |
Issue number | SUPPL. 5 |
DOIs | |
Publication status | Published - Nov 2008 |
Fingerprint
Keywords
- Bioelectrical impedance analysis
- Circumference
- Reliability
- Skinfold thickness
- Technical error of measurement
ASJC Scopus subject areas
- Medicine (miscellaneous)
- Nutrition and Dietetics
- Endocrinology, Diabetes and Metabolism
Cite this
Harmonization process and reliability assessment of anthropometric measurements in a multicenter study in adolescents. / Nagy, E.; Vicente-Rodriguez, G.; Manios, Y.; Béghin, L.; Iliescu, C.; Censi, L.; Dietrich, S.; Ortega, F. B.; De Vriendt, T.; Plada, M.; Moreno, L. A.; Molnár, D.
In: International Journal of Obesity, Vol. 32, No. SUPPL. 5, 11.2008.Research output: Contribution to journal › Article
}
TY - JOUR
T1 - Harmonization process and reliability assessment of anthropometric measurements in a multicenter study in adolescents
AU - Nagy, E.
AU - Vicente-Rodriguez, G.
AU - Manios, Y.
AU - Béghin, L.
AU - Iliescu, C.
AU - Censi, L.
AU - Dietrich, S.
AU - Ortega, F. B.
AU - De Vriendt, T.
AU - Plada, M.
AU - Moreno, L. A.
AU - Molnár, D.
PY - 2008/11
Y1 - 2008/11
N2 - Objective: To describe the standardization process and reliability of anthropometric and bioelectrical impedance analysis (BIA) measurements. We examined both intra- and interobserver errors for skinfolds, circumferences and BIA. Methods: For the intraobserver error assessment, first of all, 202 adolescents in the pilot study (110 boys, 92 girls, aged 13.64±0.78 years) were assessed. For the second intraobserver and interobserver assessments, 10 adolescents were studied (5 boys and 5 girls). Results: The pilot study's intraobserver technical errors of measurement (TEMs) were between 0.12 and 2.9 mm for skinfold thicknesses, and between 0.13 and 1.75 cm for circumferences. Intraobserver reliability for skinfold thicknesses was greater than 69.44% and beyond 78.43% for circumferences. The final workshop's intraobserver TEMs for skinfold thicknesses and circumferences were smaller than 1; for BIA resistance TEMs were smaller than 0.1 Ω and for reactance they were smaller than 0.2 Ω. Intraobserver reliability values were greater than 95, 97, 99 and 97% for skinfold thicknesses, circumferences, BIA resistance and reactance, respectively. Interobserver TEMs for skinfold thicknesses and circumferences ranged from 1 to 2 mm; for BIA they were 1.16 and 1.26 Ω for resistance and reactance, respectively. Interobserver reliability for skinfold thicknesses and circumferences were greater than 90%, and for BIA resistance and reactance they were greater than 90%. Conclusions: After the results of the pilot study, it was necessary to optimize the quality of the anthropometric measurements before the final survey. Significant improvements were observed in the intraobserver reliabilities for all measurements, with interobserver reliabilities being higher than 90% for most of the measurements.The Healthy Lifestyle in Europe by Nutrition in Adolescence Study aims to describe total body fat percentage and anthropometric indices of body fat distribution in European adolescents.
AB - Objective: To describe the standardization process and reliability of anthropometric and bioelectrical impedance analysis (BIA) measurements. We examined both intra- and interobserver errors for skinfolds, circumferences and BIA. Methods: For the intraobserver error assessment, first of all, 202 adolescents in the pilot study (110 boys, 92 girls, aged 13.64±0.78 years) were assessed. For the second intraobserver and interobserver assessments, 10 adolescents were studied (5 boys and 5 girls). Results: The pilot study's intraobserver technical errors of measurement (TEMs) were between 0.12 and 2.9 mm for skinfold thicknesses, and between 0.13 and 1.75 cm for circumferences. Intraobserver reliability for skinfold thicknesses was greater than 69.44% and beyond 78.43% for circumferences. The final workshop's intraobserver TEMs for skinfold thicknesses and circumferences were smaller than 1; for BIA resistance TEMs were smaller than 0.1 Ω and for reactance they were smaller than 0.2 Ω. Intraobserver reliability values were greater than 95, 97, 99 and 97% for skinfold thicknesses, circumferences, BIA resistance and reactance, respectively. Interobserver TEMs for skinfold thicknesses and circumferences ranged from 1 to 2 mm; for BIA they were 1.16 and 1.26 Ω for resistance and reactance, respectively. Interobserver reliability for skinfold thicknesses and circumferences were greater than 90%, and for BIA resistance and reactance they were greater than 90%. Conclusions: After the results of the pilot study, it was necessary to optimize the quality of the anthropometric measurements before the final survey. Significant improvements were observed in the intraobserver reliabilities for all measurements, with interobserver reliabilities being higher than 90% for most of the measurements.The Healthy Lifestyle in Europe by Nutrition in Adolescence Study aims to describe total body fat percentage and anthropometric indices of body fat distribution in European adolescents.
KW - Bioelectrical impedance analysis
KW - Circumference
KW - Reliability
KW - Skinfold thickness
KW - Technical error of measurement
UR - http://www.scopus.com/inward/record.url?scp=56549109180&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=56549109180&partnerID=8YFLogxK
U2 - 10.1038/ijo.2008.184
DO - 10.1038/ijo.2008.184
M3 - Article
C2 - 19011655
AN - SCOPUS:56549109180
VL - 32
JO - International Journal of Obesity
JF - International Journal of Obesity
SN - 0307-0565
IS - SUPPL. 5
ER -