Guiding of Ar7+ ions through a glass microcapillary array

P. Herczku, Z. Juhász, S. T S Kovács, R. Rácz, S. Biri, B. Sulik

Research output: Contribution to journalArticle

Abstract

We studied the guiding effect in a glass microcapillary array with similar dimensions as for a Multi Channel Plate (MCP) detector. Unexpected irregularities were found in the angular distribution of the transmitted ions during the time evolution.

Original languageEnglish
Article number132011
JournalJournal of Physics: Conference Series
Volume488
Issue numberSECTION 13
DOIs
Publication statusPublished - 2014

Fingerprint

microchannel plates
irregularities
angular distribution
glass
detectors
ions

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Guiding of Ar7+ ions through a glass microcapillary array. / Herczku, P.; Juhász, Z.; Kovács, S. T S; Rácz, R.; Biri, S.; Sulik, B.

In: Journal of Physics: Conference Series, Vol. 488, No. SECTION 13, 132011, 2014.

Research output: Contribution to journalArticle

@article{4e8471fec07a45f58804b6bf98242aa7,
title = "Guiding of Ar7+ ions through a glass microcapillary array",
abstract = "We studied the guiding effect in a glass microcapillary array with similar dimensions as for a Multi Channel Plate (MCP) detector. Unexpected irregularities were found in the angular distribution of the transmitted ions during the time evolution.",
author = "P. Herczku and Z. Juh{\'a}sz and Kov{\'a}cs, {S. T S} and R. R{\'a}cz and S. Biri and B. Sulik",
year = "2014",
doi = "10.1088/1742-6596/488/13/132011",
language = "English",
volume = "488",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",
number = "SECTION 13",

}

TY - JOUR

T1 - Guiding of Ar7+ ions through a glass microcapillary array

AU - Herczku, P.

AU - Juhász, Z.

AU - Kovács, S. T S

AU - Rácz, R.

AU - Biri, S.

AU - Sulik, B.

PY - 2014

Y1 - 2014

N2 - We studied the guiding effect in a glass microcapillary array with similar dimensions as for a Multi Channel Plate (MCP) detector. Unexpected irregularities were found in the angular distribution of the transmitted ions during the time evolution.

AB - We studied the guiding effect in a glass microcapillary array with similar dimensions as for a Multi Channel Plate (MCP) detector. Unexpected irregularities were found in the angular distribution of the transmitted ions during the time evolution.

UR - http://www.scopus.com/inward/record.url?scp=84903703828&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84903703828&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/488/13/132011

DO - 10.1088/1742-6596/488/13/132011

M3 - Article

VL - 488

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - SECTION 13

M1 - 132011

ER -