Gated tomographic imaging in ectomography using a dynamic heart phantom

I. Valastyán, D. Bone, L. Å Brodin, H. Elmqvist, A. Kerek, J. Molnár, D. Novák, T. Ribbe

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

A new computer controlled dynamic heart phantom and the connection of an ECG unit to a tomographic gamma camera system, developed for ectomographic imaging, is presented. The phantom is used for validation of the camera. Measurements were performed to test the phantom as well as to study the feasibility of gated imaging in ectomography. The camera is intended for early diagnosis of myocardial and cerebral infarctions.

Original languageEnglish
Title of host publicationIEEE Nuclear Science Symposium Conference Record
Pages3414-3417
Number of pages4
Volume5
DOIs
Publication statusPublished - 2007
Event2007 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS-MIC - Honolulu, HI, United States
Duration: Oct 27 2007Nov 3 2007

Other

Other2007 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS-MIC
CountryUnited States
CityHonolulu, HI
Period10/27/0711/3/07

Fingerprint

Cameras
Imaging techniques
Electrocardiography

ASJC Scopus subject areas

  • Computer Vision and Pattern Recognition
  • Industrial and Manufacturing Engineering

Cite this

Valastyán, I., Bone, D., Brodin, L. Å., Elmqvist, H., Kerek, A., Molnár, J., ... Ribbe, T. (2007). Gated tomographic imaging in ectomography using a dynamic heart phantom. In IEEE Nuclear Science Symposium Conference Record (Vol. 5, pp. 3414-3417). [4436863] https://doi.org/10.1109/NSSMIC.2007.4436863

Gated tomographic imaging in ectomography using a dynamic heart phantom. / Valastyán, I.; Bone, D.; Brodin, L. Å; Elmqvist, H.; Kerek, A.; Molnár, J.; Novák, D.; Ribbe, T.

IEEE Nuclear Science Symposium Conference Record. Vol. 5 2007. p. 3414-3417 4436863.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Valastyán, I, Bone, D, Brodin, LÅ, Elmqvist, H, Kerek, A, Molnár, J, Novák, D & Ribbe, T 2007, Gated tomographic imaging in ectomography using a dynamic heart phantom. in IEEE Nuclear Science Symposium Conference Record. vol. 5, 4436863, pp. 3414-3417, 2007 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS-MIC, Honolulu, HI, United States, 10/27/07. https://doi.org/10.1109/NSSMIC.2007.4436863
Valastyán I, Bone D, Brodin LÅ, Elmqvist H, Kerek A, Molnár J et al. Gated tomographic imaging in ectomography using a dynamic heart phantom. In IEEE Nuclear Science Symposium Conference Record. Vol. 5. 2007. p. 3414-3417. 4436863 https://doi.org/10.1109/NSSMIC.2007.4436863
Valastyán, I. ; Bone, D. ; Brodin, L. Å ; Elmqvist, H. ; Kerek, A. ; Molnár, J. ; Novák, D. ; Ribbe, T. / Gated tomographic imaging in ectomography using a dynamic heart phantom. IEEE Nuclear Science Symposium Conference Record. Vol. 5 2007. pp. 3414-3417
@inproceedings{ed63136360164d4d866d64ed3b714ad4,
title = "Gated tomographic imaging in ectomography using a dynamic heart phantom",
abstract = "A new computer controlled dynamic heart phantom and the connection of an ECG unit to a tomographic gamma camera system, developed for ectomographic imaging, is presented. The phantom is used for validation of the camera. Measurements were performed to test the phantom as well as to study the feasibility of gated imaging in ectomography. The camera is intended for early diagnosis of myocardial and cerebral infarctions.",
author = "I. Valasty{\'a}n and D. Bone and Brodin, {L. {\AA}} and H. Elmqvist and A. Kerek and J. Moln{\'a}r and D. Nov{\'a}k and T. Ribbe",
year = "2007",
doi = "10.1109/NSSMIC.2007.4436863",
language = "English",
isbn = "1424409233",
volume = "5",
pages = "3414--3417",
booktitle = "IEEE Nuclear Science Symposium Conference Record",

}

TY - GEN

T1 - Gated tomographic imaging in ectomography using a dynamic heart phantom

AU - Valastyán, I.

AU - Bone, D.

AU - Brodin, L. Å

AU - Elmqvist, H.

AU - Kerek, A.

AU - Molnár, J.

AU - Novák, D.

AU - Ribbe, T.

PY - 2007

Y1 - 2007

N2 - A new computer controlled dynamic heart phantom and the connection of an ECG unit to a tomographic gamma camera system, developed for ectomographic imaging, is presented. The phantom is used for validation of the camera. Measurements were performed to test the phantom as well as to study the feasibility of gated imaging in ectomography. The camera is intended for early diagnosis of myocardial and cerebral infarctions.

AB - A new computer controlled dynamic heart phantom and the connection of an ECG unit to a tomographic gamma camera system, developed for ectomographic imaging, is presented. The phantom is used for validation of the camera. Measurements were performed to test the phantom as well as to study the feasibility of gated imaging in ectomography. The camera is intended for early diagnosis of myocardial and cerebral infarctions.

UR - http://www.scopus.com/inward/record.url?scp=48349132721&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=48349132721&partnerID=8YFLogxK

U2 - 10.1109/NSSMIC.2007.4436863

DO - 10.1109/NSSMIC.2007.4436863

M3 - Conference contribution

AN - SCOPUS:48349132721

SN - 1424409233

SN - 9781424409235

VL - 5

SP - 3414

EP - 3417

BT - IEEE Nuclear Science Symposium Conference Record

ER -