Fourier analysis of multicomponent chromatograms. Numerical evaluation of statistical parameters

A. Felinger, Luisa Pasti, Pierluigi Reschiglian, Francesco Dondi

Research output: Contribution to journalArticle

40 Citations (Scopus)

Abstract

A procedure based on the power spectrum (PS) model of a multicomponent chromatogram is introduced by which the number m of detectable components (or single-component peaks) and the parameters of the single-component peak such as standard deviation and asymmetry factor can be evaluated. In essence, when fitted to theoretical models, the experimental PS - expressing the chromatographic response variance dependence on the time distance - provides the information necessary to accept or reject the model and to give the necessary parameter estimations. The procedure is tested by using computer-generated multicomponent chromatograms with Poissonian retention time distribution and random and uncorrelated peak heights, in which density, asymmetry and height distribution are widely varied. How to obtain unbiased PS numerical determination by windowing is also discussed. It is shown that unbiased parameter estimations are obtained, the only procedure limitation being the approximation made in the evaluation of the single-component peak height dispersion. An example is given of how a retention time distribution other than the Poissonian can be detected.

Original languageEnglish
Pages (from-to)1854-1860
Number of pages7
JournalAnalytical Chemistry
Volume62
Issue number17
Publication statusPublished - Sep 1 1990

Fingerprint

Fourier analysis
Power spectrum
Parameter estimation

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Fourier analysis of multicomponent chromatograms. Numerical evaluation of statistical parameters. / Felinger, A.; Pasti, Luisa; Reschiglian, Pierluigi; Dondi, Francesco.

In: Analytical Chemistry, Vol. 62, No. 17, 01.09.1990, p. 1854-1860.

Research output: Contribution to journalArticle

Felinger, A. ; Pasti, Luisa ; Reschiglian, Pierluigi ; Dondi, Francesco. / Fourier analysis of multicomponent chromatograms. Numerical evaluation of statistical parameters. In: Analytical Chemistry. 1990 ; Vol. 62, No. 17. pp. 1854-1860.
@article{a46ae9546ca14227beccc2f7732a5874,
title = "Fourier analysis of multicomponent chromatograms. Numerical evaluation of statistical parameters",
abstract = "A procedure based on the power spectrum (PS) model of a multicomponent chromatogram is introduced by which the number m of detectable components (or single-component peaks) and the parameters of the single-component peak such as standard deviation and asymmetry factor can be evaluated. In essence, when fitted to theoretical models, the experimental PS - expressing the chromatographic response variance dependence on the time distance - provides the information necessary to accept or reject the model and to give the necessary parameter estimations. The procedure is tested by using computer-generated multicomponent chromatograms with Poissonian retention time distribution and random and uncorrelated peak heights, in which density, asymmetry and height distribution are widely varied. How to obtain unbiased PS numerical determination by windowing is also discussed. It is shown that unbiased parameter estimations are obtained, the only procedure limitation being the approximation made in the evaluation of the single-component peak height dispersion. An example is given of how a retention time distribution other than the Poissonian can be detected.",
author = "A. Felinger and Luisa Pasti and Pierluigi Reschiglian and Francesco Dondi",
year = "1990",
month = "9",
day = "1",
language = "English",
volume = "62",
pages = "1854--1860",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "17",

}

TY - JOUR

T1 - Fourier analysis of multicomponent chromatograms. Numerical evaluation of statistical parameters

AU - Felinger, A.

AU - Pasti, Luisa

AU - Reschiglian, Pierluigi

AU - Dondi, Francesco

PY - 1990/9/1

Y1 - 1990/9/1

N2 - A procedure based on the power spectrum (PS) model of a multicomponent chromatogram is introduced by which the number m of detectable components (or single-component peaks) and the parameters of the single-component peak such as standard deviation and asymmetry factor can be evaluated. In essence, when fitted to theoretical models, the experimental PS - expressing the chromatographic response variance dependence on the time distance - provides the information necessary to accept or reject the model and to give the necessary parameter estimations. The procedure is tested by using computer-generated multicomponent chromatograms with Poissonian retention time distribution and random and uncorrelated peak heights, in which density, asymmetry and height distribution are widely varied. How to obtain unbiased PS numerical determination by windowing is also discussed. It is shown that unbiased parameter estimations are obtained, the only procedure limitation being the approximation made in the evaluation of the single-component peak height dispersion. An example is given of how a retention time distribution other than the Poissonian can be detected.

AB - A procedure based on the power spectrum (PS) model of a multicomponent chromatogram is introduced by which the number m of detectable components (or single-component peaks) and the parameters of the single-component peak such as standard deviation and asymmetry factor can be evaluated. In essence, when fitted to theoretical models, the experimental PS - expressing the chromatographic response variance dependence on the time distance - provides the information necessary to accept or reject the model and to give the necessary parameter estimations. The procedure is tested by using computer-generated multicomponent chromatograms with Poissonian retention time distribution and random and uncorrelated peak heights, in which density, asymmetry and height distribution are widely varied. How to obtain unbiased PS numerical determination by windowing is also discussed. It is shown that unbiased parameter estimations are obtained, the only procedure limitation being the approximation made in the evaluation of the single-component peak height dispersion. An example is given of how a retention time distribution other than the Poissonian can be detected.

UR - http://www.scopus.com/inward/record.url?scp=0007595114&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0007595114&partnerID=8YFLogxK

M3 - Article

VL - 62

SP - 1854

EP - 1860

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 17

ER -