Foam chromatography solid foams as supports in column chromatography

T. Braun, A. B. Parag

Research output: Contribution to journalArticle

40 Citations (Scopus)

Abstract

Foamed polymer is loaded with tributyl phosphate as stationary phase and compressed into a Chromatographic column which will give flow rates of 1-4 ml min, has a high break-through capacity and gives sharp and symmetrical peaks in elution chromatography. It has been applied to separation of nickel and palladium.

Original languageEnglish
Pages (from-to)828-830
Number of pages3
JournalTalanta
Volume19
Issue number6
DOIs
Publication statusPublished - 1972

Fingerprint

Column chromatography
Palladium
Chromatography
Nickel
Foams
Polymers
Flow rate
tributyl phosphate

ASJC Scopus subject areas

  • Analytical Chemistry
  • Spectroscopy

Cite this

Foam chromatography solid foams as supports in column chromatography. / Braun, T.; Parag, A. B.

In: Talanta, Vol. 19, No. 6, 1972, p. 828-830.

Research output: Contribution to journalArticle

Braun, T. ; Parag, A. B. / Foam chromatography solid foams as supports in column chromatography. In: Talanta. 1972 ; Vol. 19, No. 6. pp. 828-830.
@article{bc6a5baa52d64897bc00bb07436206a5,
title = "Foam chromatography solid foams as supports in column chromatography",
abstract = "Foamed polymer is loaded with tributyl phosphate as stationary phase and compressed into a Chromatographic column which will give flow rates of 1-4 ml min, has a high break-through capacity and gives sharp and symmetrical peaks in elution chromatography. It has been applied to separation of nickel and palladium.",
author = "T. Braun and Parag, {A. B.}",
year = "1972",
doi = "10.1016/0039-9140(72)80019-5",
language = "English",
volume = "19",
pages = "828--830",
journal = "Talanta",
issn = "0039-9140",
publisher = "Elsevier",
number = "6",

}

TY - JOUR

T1 - Foam chromatography solid foams as supports in column chromatography

AU - Braun, T.

AU - Parag, A. B.

PY - 1972

Y1 - 1972

N2 - Foamed polymer is loaded with tributyl phosphate as stationary phase and compressed into a Chromatographic column which will give flow rates of 1-4 ml min, has a high break-through capacity and gives sharp and symmetrical peaks in elution chromatography. It has been applied to separation of nickel and palladium.

AB - Foamed polymer is loaded with tributyl phosphate as stationary phase and compressed into a Chromatographic column which will give flow rates of 1-4 ml min, has a high break-through capacity and gives sharp and symmetrical peaks in elution chromatography. It has been applied to separation of nickel and palladium.

UR - http://www.scopus.com/inward/record.url?scp=0005908821&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0005908821&partnerID=8YFLogxK

U2 - 10.1016/0039-9140(72)80019-5

DO - 10.1016/0039-9140(72)80019-5

M3 - Article

VL - 19

SP - 828

EP - 830

JO - Talanta

JF - Talanta

SN - 0039-9140

IS - 6

ER -