Flux measurement of sputtered atoms with LIF method in one laser shot

J. Bakos, P. Lásztity

Research output: Contribution to journalArticle

Abstract

An experimental set-up is proposed for measuring impurity atom fluxes in fusion devices "in situ" with the aid of LIF method by using only one laser shot. It is shown that this method has the same sensitivity as that of earlier measuring arrangements.

Original languageEnglish
Pages (from-to)347-352
Number of pages6
JournalActa Physica Hungarica
Volume63
Issue number3-4
DOIs
Publication statusPublished - Jun 1988

Fingerprint

laser induced fluorescence
shot
lasers
atoms
fusion
impurities
sensitivity

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Flux measurement of sputtered atoms with LIF method in one laser shot. / Bakos, J.; Lásztity, P.

In: Acta Physica Hungarica, Vol. 63, No. 3-4, 06.1988, p. 347-352.

Research output: Contribution to journalArticle

@article{69d0a2e816cc452ea0107c27b200d64a,
title = "Flux measurement of sputtered atoms with LIF method in one laser shot",
abstract = "An experimental set-up is proposed for measuring impurity atom fluxes in fusion devices {"}in situ{"} with the aid of LIF method by using only one laser shot. It is shown that this method has the same sensitivity as that of earlier measuring arrangements.",
author = "J. Bakos and P. L{\'a}sztity",
year = "1988",
month = "6",
doi = "10.1007/BF03156025",
language = "English",
volume = "63",
pages = "347--352",
journal = "Acta Physica Hungarica",
issn = "0231-4428",
publisher = "Akademiai Kiado",
number = "3-4",

}

TY - JOUR

T1 - Flux measurement of sputtered atoms with LIF method in one laser shot

AU - Bakos, J.

AU - Lásztity, P.

PY - 1988/6

Y1 - 1988/6

N2 - An experimental set-up is proposed for measuring impurity atom fluxes in fusion devices "in situ" with the aid of LIF method by using only one laser shot. It is shown that this method has the same sensitivity as that of earlier measuring arrangements.

AB - An experimental set-up is proposed for measuring impurity atom fluxes in fusion devices "in situ" with the aid of LIF method by using only one laser shot. It is shown that this method has the same sensitivity as that of earlier measuring arrangements.

UR - http://www.scopus.com/inward/record.url?scp=77951512391&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77951512391&partnerID=8YFLogxK

U2 - 10.1007/BF03156025

DO - 10.1007/BF03156025

M3 - Article

VL - 63

SP - 347

EP - 352

JO - Acta Physica Hungarica

JF - Acta Physica Hungarica

SN - 0231-4428

IS - 3-4

ER -