Finite-element modeling of posterior lamellar keratoplasty: Construction of theoretical nomograms for induced refractive errors

G. Djotyan, H. Kaz Soong, Shahzad Mian, Delia C. Fernández, Ronald M. Kurtz, Tibor Juhasz

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

Purpose: To estimate the theoretical corneal refractive error induced by mechanical weakening effects from posterior lamellar keratoplasty (PLKP) in the human cornea. Methods: The refractive effects of PLKP are simulated by finite-element modeling (FEM) as a mathematical function of the thickness of the excised posterior lamellar corneal button, with a nonlinear formulation of stress-strain relation for the corneal material. A theoretical nomogram was developed to correlate the refractive changes to button thickness. Results: The predicted refractive change after PLKP is less than 1 dpt for a 170-μm thickness posterior corneal button over a broad range of Young's modulus. Thicker buttons result in greater surgically induced refractive errors. Conclusions: According to FEM analysis, the excision of a posterior lamellar button of less than 170 μm thickness produces a minimal predicted refractive change (

Original languageEnglish
Pages (from-to)329-334
Number of pages6
JournalOphthalmic Research
Volume38
Issue number6
DOIs
Publication statusPublished - Nov 2006

Fingerprint

Nomograms
Corneal Transplantation
Refractive Errors
Finite Element Analysis
Elastic Modulus
Cornea

Keywords

  • Posterior lamellar keratoplasty, mathematical modeling
  • Refractive error

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Finite-element modeling of posterior lamellar keratoplasty : Construction of theoretical nomograms for induced refractive errors. / Djotyan, G.; Soong, H. Kaz; Mian, Shahzad; Fernández, Delia C.; Kurtz, Ronald M.; Juhasz, Tibor.

In: Ophthalmic Research, Vol. 38, No. 6, 11.2006, p. 329-334.

Research output: Contribution to journalArticle

Djotyan, G. ; Soong, H. Kaz ; Mian, Shahzad ; Fernández, Delia C. ; Kurtz, Ronald M. ; Juhasz, Tibor. / Finite-element modeling of posterior lamellar keratoplasty : Construction of theoretical nomograms for induced refractive errors. In: Ophthalmic Research. 2006 ; Vol. 38, No. 6. pp. 329-334.
@article{4b3da58baa74412f9b1f6ab2d4c2c586,
title = "Finite-element modeling of posterior lamellar keratoplasty: Construction of theoretical nomograms for induced refractive errors",
abstract = "Purpose: To estimate the theoretical corneal refractive error induced by mechanical weakening effects from posterior lamellar keratoplasty (PLKP) in the human cornea. Methods: The refractive effects of PLKP are simulated by finite-element modeling (FEM) as a mathematical function of the thickness of the excised posterior lamellar corneal button, with a nonlinear formulation of stress-strain relation for the corneal material. A theoretical nomogram was developed to correlate the refractive changes to button thickness. Results: The predicted refractive change after PLKP is less than 1 dpt for a 170-μm thickness posterior corneal button over a broad range of Young's modulus. Thicker buttons result in greater surgically induced refractive errors. Conclusions: According to FEM analysis, the excision of a posterior lamellar button of less than 170 μm thickness produces a minimal predicted refractive change (",
keywords = "Posterior lamellar keratoplasty, mathematical modeling, Refractive error",
author = "G. Djotyan and Soong, {H. Kaz} and Shahzad Mian and Fern{\'a}ndez, {Delia C.} and Kurtz, {Ronald M.} and Tibor Juhasz",
year = "2006",
month = "11",
doi = "10.1159/000096227",
language = "English",
volume = "38",
pages = "329--334",
journal = "Ophthalmic Research",
issn = "0030-3747",
publisher = "S. Karger AG",
number = "6",

}

TY - JOUR

T1 - Finite-element modeling of posterior lamellar keratoplasty

T2 - Construction of theoretical nomograms for induced refractive errors

AU - Djotyan, G.

AU - Soong, H. Kaz

AU - Mian, Shahzad

AU - Fernández, Delia C.

AU - Kurtz, Ronald M.

AU - Juhasz, Tibor

PY - 2006/11

Y1 - 2006/11

N2 - Purpose: To estimate the theoretical corneal refractive error induced by mechanical weakening effects from posterior lamellar keratoplasty (PLKP) in the human cornea. Methods: The refractive effects of PLKP are simulated by finite-element modeling (FEM) as a mathematical function of the thickness of the excised posterior lamellar corneal button, with a nonlinear formulation of stress-strain relation for the corneal material. A theoretical nomogram was developed to correlate the refractive changes to button thickness. Results: The predicted refractive change after PLKP is less than 1 dpt for a 170-μm thickness posterior corneal button over a broad range of Young's modulus. Thicker buttons result in greater surgically induced refractive errors. Conclusions: According to FEM analysis, the excision of a posterior lamellar button of less than 170 μm thickness produces a minimal predicted refractive change (

AB - Purpose: To estimate the theoretical corneal refractive error induced by mechanical weakening effects from posterior lamellar keratoplasty (PLKP) in the human cornea. Methods: The refractive effects of PLKP are simulated by finite-element modeling (FEM) as a mathematical function of the thickness of the excised posterior lamellar corneal button, with a nonlinear formulation of stress-strain relation for the corneal material. A theoretical nomogram was developed to correlate the refractive changes to button thickness. Results: The predicted refractive change after PLKP is less than 1 dpt for a 170-μm thickness posterior corneal button over a broad range of Young's modulus. Thicker buttons result in greater surgically induced refractive errors. Conclusions: According to FEM analysis, the excision of a posterior lamellar button of less than 170 μm thickness produces a minimal predicted refractive change (

KW - Posterior lamellar keratoplasty, mathematical modeling

KW - Refractive error

UR - http://www.scopus.com/inward/record.url?scp=33750688893&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33750688893&partnerID=8YFLogxK

U2 - 10.1159/000096227

DO - 10.1159/000096227

M3 - Article

C2 - 17047405

AN - SCOPUS:33750688893

VL - 38

SP - 329

EP - 334

JO - Ophthalmic Research

JF - Ophthalmic Research

SN - 0030-3747

IS - 6

ER -