Evaluation of a new software version of the RTVue optical coherence tomograph for image segmentation and detection of glaucoma in high myopia

G. Holló, Hsu Shu-Wei, Farzaneh Naghizadeh

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Purpose: To compare the current (6.3) and a novel software version (6.12) of the RTVue-100 optical coherence tomograph (RTVue-OCT) for ganglion cell complex (GCC) and retinal nerve fiber layer thickness (RNFLT) image segmentation and detection of glaucoma in high myopia. Materials and Methods: RNFLT and GCC scans were acquired with software version 6.3 of the RTVue-OCT on 51 highly myopic eyes (spherical refractive error ≤-6.0 D) of 51 patients, and were analyzed with both the software versions. Twenty-two eyes were nonglaucomatous, 13 were ocular hypertensive and 16 eyes had glaucoma. Results: No difference was seen for any RNFLT, and average GCC parameter between the software versions (paired t test, P≥0.084). Global loss volume was significantly lower (more normal) with version 6.12 than with version 6.3 (Wilcoxon signed-rank test, P

Original languageEnglish
Pages (from-to)e615-e619
JournalJournal of Glaucoma
Volume25
Issue number6
DOIs
Publication statusPublished - 2016

Fingerprint

Myopia
Glaucoma
Software
Nerve Fibers
Ganglia
Refractive Errors
Retinal Ganglion Cells
Nonparametric Statistics

Keywords

  • ganglion cell complex
  • high myopia
  • retinal nerve fiber layer thickness
  • RTVue-100 Fourier-domain optical coherence tomograph

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Evaluation of a new software version of the RTVue optical coherence tomograph for image segmentation and detection of glaucoma in high myopia. / Holló, G.; Shu-Wei, Hsu; Naghizadeh, Farzaneh.

In: Journal of Glaucoma, Vol. 25, No. 6, 2016, p. e615-e619.

Research output: Contribution to journalArticle

@article{ba2eda1c466b45bd8bfb4c948c4af361,
title = "Evaluation of a new software version of the RTVue optical coherence tomograph for image segmentation and detection of glaucoma in high myopia",
abstract = "Purpose: To compare the current (6.3) and a novel software version (6.12) of the RTVue-100 optical coherence tomograph (RTVue-OCT) for ganglion cell complex (GCC) and retinal nerve fiber layer thickness (RNFLT) image segmentation and detection of glaucoma in high myopia. Materials and Methods: RNFLT and GCC scans were acquired with software version 6.3 of the RTVue-OCT on 51 highly myopic eyes (spherical refractive error ≤-6.0 D) of 51 patients, and were analyzed with both the software versions. Twenty-two eyes were nonglaucomatous, 13 were ocular hypertensive and 16 eyes had glaucoma. Results: No difference was seen for any RNFLT, and average GCC parameter between the software versions (paired t test, P≥0.084). Global loss volume was significantly lower (more normal) with version 6.12 than with version 6.3 (Wilcoxon signed-rank test, P",
keywords = "ganglion cell complex, high myopia, retinal nerve fiber layer thickness, RTVue-100 Fourier-domain optical coherence tomograph",
author = "G. Holl{\'o} and Hsu Shu-Wei and Farzaneh Naghizadeh",
year = "2016",
doi = "10.1097/IJG.0000000000000290",
language = "English",
volume = "25",
pages = "e615--e619",
journal = "Journal of Glaucoma",
issn = "1057-0829",
publisher = "Lippincott Williams and Wilkins",
number = "6",

}

TY - JOUR

T1 - Evaluation of a new software version of the RTVue optical coherence tomograph for image segmentation and detection of glaucoma in high myopia

AU - Holló, G.

AU - Shu-Wei, Hsu

AU - Naghizadeh, Farzaneh

PY - 2016

Y1 - 2016

N2 - Purpose: To compare the current (6.3) and a novel software version (6.12) of the RTVue-100 optical coherence tomograph (RTVue-OCT) for ganglion cell complex (GCC) and retinal nerve fiber layer thickness (RNFLT) image segmentation and detection of glaucoma in high myopia. Materials and Methods: RNFLT and GCC scans were acquired with software version 6.3 of the RTVue-OCT on 51 highly myopic eyes (spherical refractive error ≤-6.0 D) of 51 patients, and were analyzed with both the software versions. Twenty-two eyes were nonglaucomatous, 13 were ocular hypertensive and 16 eyes had glaucoma. Results: No difference was seen for any RNFLT, and average GCC parameter between the software versions (paired t test, P≥0.084). Global loss volume was significantly lower (more normal) with version 6.12 than with version 6.3 (Wilcoxon signed-rank test, P

AB - Purpose: To compare the current (6.3) and a novel software version (6.12) of the RTVue-100 optical coherence tomograph (RTVue-OCT) for ganglion cell complex (GCC) and retinal nerve fiber layer thickness (RNFLT) image segmentation and detection of glaucoma in high myopia. Materials and Methods: RNFLT and GCC scans were acquired with software version 6.3 of the RTVue-OCT on 51 highly myopic eyes (spherical refractive error ≤-6.0 D) of 51 patients, and were analyzed with both the software versions. Twenty-two eyes were nonglaucomatous, 13 were ocular hypertensive and 16 eyes had glaucoma. Results: No difference was seen for any RNFLT, and average GCC parameter between the software versions (paired t test, P≥0.084). Global loss volume was significantly lower (more normal) with version 6.12 than with version 6.3 (Wilcoxon signed-rank test, P

KW - ganglion cell complex

KW - high myopia

KW - retinal nerve fiber layer thickness

KW - RTVue-100 Fourier-domain optical coherence tomograph

UR - http://www.scopus.com/inward/record.url?scp=84975295470&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84975295470&partnerID=8YFLogxK

U2 - 10.1097/IJG.0000000000000290

DO - 10.1097/IJG.0000000000000290

M3 - Article

C2 - 26066501

AN - SCOPUS:84975295470

VL - 25

SP - e615-e619

JO - Journal of Glaucoma

JF - Journal of Glaucoma

SN - 1057-0829

IS - 6

ER -