Enhanced sensitivity of oxygen detection of 3.045 MeV (α, α) elastic scattering and its applications

G. Mezey, E. Kótai, P. Révész, A. Manuaba, T. Lohner, J. Gyulai, M. Fried, Gy Vizkelethy, F. Pászti, G. Battistig, M. Somogyi

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Based on a simple theoretical background, numerous applications of the16O(α, α)16O reaction are reviewed. The reaction lowers the detection limit of the conventional RBS by a factor of 17. The advantages of the method for several applications will be discussed.

Original languageEnglish
Pages (from-to)39-55
Number of pages17
JournalActa Physica Hungarica
Volume58
Issue number1-2
DOIs
Publication statusPublished - Sep 1985

Fingerprint

elastic scattering
sensitivity
oxygen

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Enhanced sensitivity of oxygen detection of 3.045 MeV (α, α) elastic scattering and its applications. / Mezey, G.; Kótai, E.; Révész, P.; Manuaba, A.; Lohner, T.; Gyulai, J.; Fried, M.; Vizkelethy, Gy; Pászti, F.; Battistig, G.; Somogyi, M.

In: Acta Physica Hungarica, Vol. 58, No. 1-2, 09.1985, p. 39-55.

Research output: Contribution to journalArticle

Mezey, G. ; Kótai, E. ; Révész, P. ; Manuaba, A. ; Lohner, T. ; Gyulai, J. ; Fried, M. ; Vizkelethy, Gy ; Pászti, F. ; Battistig, G. ; Somogyi, M. / Enhanced sensitivity of oxygen detection of 3.045 MeV (α, α) elastic scattering and its applications. In: Acta Physica Hungarica. 1985 ; Vol. 58, No. 1-2. pp. 39-55.
@article{f64b423889f64365b77b2e6300602148,
title = "Enhanced sensitivity of oxygen detection of 3.045 MeV (α, α) elastic scattering and its applications",
abstract = "Based on a simple theoretical background, numerous applications of the16O(α, α)16O reaction are reviewed. The reaction lowers the detection limit of the conventional RBS by a factor of 17. The advantages of the method for several applications will be discussed.",
author = "G. Mezey and E. K{\'o}tai and P. R{\'e}v{\'e}sz and A. Manuaba and T. Lohner and J. Gyulai and M. Fried and Gy Vizkelethy and F. P{\'a}szti and G. Battistig and M. Somogyi",
year = "1985",
month = "9",
doi = "10.1007/BF03155695",
language = "English",
volume = "58",
pages = "39--55",
journal = "Acta Physica Hungarica",
issn = "0231-4428",
publisher = "Akademiai Kiado",
number = "1-2",

}

TY - JOUR

T1 - Enhanced sensitivity of oxygen detection of 3.045 MeV (α, α) elastic scattering and its applications

AU - Mezey, G.

AU - Kótai, E.

AU - Révész, P.

AU - Manuaba, A.

AU - Lohner, T.

AU - Gyulai, J.

AU - Fried, M.

AU - Vizkelethy, Gy

AU - Pászti, F.

AU - Battistig, G.

AU - Somogyi, M.

PY - 1985/9

Y1 - 1985/9

N2 - Based on a simple theoretical background, numerous applications of the16O(α, α)16O reaction are reviewed. The reaction lowers the detection limit of the conventional RBS by a factor of 17. The advantages of the method for several applications will be discussed.

AB - Based on a simple theoretical background, numerous applications of the16O(α, α)16O reaction are reviewed. The reaction lowers the detection limit of the conventional RBS by a factor of 17. The advantages of the method for several applications will be discussed.

UR - http://www.scopus.com/inward/record.url?scp=77951510329&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77951510329&partnerID=8YFLogxK

U2 - 10.1007/BF03155695

DO - 10.1007/BF03155695

M3 - Article

VL - 58

SP - 39

EP - 55

JO - Acta Physica Hungarica

JF - Acta Physica Hungarica

SN - 0231-4428

IS - 1-2

ER -