ELECTRON DOSE DETERMINATION BY ETHANOL-MONOCHLOROBENZENE DOSIMETER.

A. Kovacs, A. Miller

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

The dosimeter solution of the same composition, offered by IAEA as a back-up system for gamma radiation processing, was studied by using the 10 MeV linear accelerator of the Accelerator Department at Riso National Laboratory. The G/C1** minus / value of the system was determined by measuring the dose with water calorimeters. The applicability of the dosimeter solution was checked in the dose range of 1-100 kGy.

Original languageEnglish
Pages (from-to)531-533
Number of pages3
JournalRadiation Physics and Chemistry
Volume28
Issue number5-6
Publication statusPublished - 1986

Fingerprint

dosimeters
ethyl alcohol
dosage
linear accelerators
calorimeters
accelerators
electrons
gamma rays
water

ASJC Scopus subject areas

  • Radiation

Cite this

ELECTRON DOSE DETERMINATION BY ETHANOL-MONOCHLOROBENZENE DOSIMETER. / Kovacs, A.; Miller, A.

In: Radiation Physics and Chemistry, Vol. 28, No. 5-6, 1986, p. 531-533.

Research output: Contribution to journalArticle

@article{d88fdf19b1134a4484e7e034f8291127,
title = "ELECTRON DOSE DETERMINATION BY ETHANOL-MONOCHLOROBENZENE DOSIMETER.",
abstract = "The dosimeter solution of the same composition, offered by IAEA as a back-up system for gamma radiation processing, was studied by using the 10 MeV linear accelerator of the Accelerator Department at Riso National Laboratory. The G/C1** minus / value of the system was determined by measuring the dose with water calorimeters. The applicability of the dosimeter solution was checked in the dose range of 1-100 kGy.",
author = "A. Kovacs and A. Miller",
year = "1986",
language = "English",
volume = "28",
pages = "531--533",
journal = "Radiation Physics and Chemistry",
issn = "0969-806X",
publisher = "Elsevier Limited",
number = "5-6",

}

TY - JOUR

T1 - ELECTRON DOSE DETERMINATION BY ETHANOL-MONOCHLOROBENZENE DOSIMETER.

AU - Kovacs, A.

AU - Miller, A.

PY - 1986

Y1 - 1986

N2 - The dosimeter solution of the same composition, offered by IAEA as a back-up system for gamma radiation processing, was studied by using the 10 MeV linear accelerator of the Accelerator Department at Riso National Laboratory. The G/C1** minus / value of the system was determined by measuring the dose with water calorimeters. The applicability of the dosimeter solution was checked in the dose range of 1-100 kGy.

AB - The dosimeter solution of the same composition, offered by IAEA as a back-up system for gamma radiation processing, was studied by using the 10 MeV linear accelerator of the Accelerator Department at Riso National Laboratory. The G/C1** minus / value of the system was determined by measuring the dose with water calorimeters. The applicability of the dosimeter solution was checked in the dose range of 1-100 kGy.

UR - http://www.scopus.com/inward/record.url?scp=0022961043&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022961043&partnerID=8YFLogxK

M3 - Article

VL - 28

SP - 531

EP - 533

JO - Radiation Physics and Chemistry

JF - Radiation Physics and Chemistry

SN - 0969-806X

IS - 5-6

ER -