Abstract

The combination of electromagnetic (EM) navigation with intraoperative fluoroscopic images has the potential to create the ideal environment for spinal surgical applications. This technology enhances standard intraoperative fluoroscopic information for localization of the pedicle entry point and trajectory and may be an effective alternative to other image-guided surgery (IGS) systems. This study was performed to assess the accuracy and time efficiency (placement and fluoroscopy) using EM navigation versus conventional fluoroscopy in the placement of pedicle guide-wires. Kirschner wire (K-wire) placement was performed in cadavers from T8 to S1 using EM navigation versus conventional fluoroscopy. Time for set-up, placement, and fluoroscopy was recorded. After insertion, the accuracy for each level was assessed for the presence and location of facet joint, pedicle, or vertebral cortical perforation using computed tomography imaging with multiplanar reconstructions. K-wire placements were 100% successful for both methods. Comparing EM-based IGS-assisted placement with the conventional fluoroscopy method showed a longer set-up time of 9.6 min versus 3.6 min, respectively. However, mean placement times of 6.3 min versus 9.7 min (P = 0.005) and mean fluoroscopy times of 11 s versus 48 s (P <0.0001) were both shorter for the EM group. There were no significant differences in the proportion of pedicle, vertebral body, or facet joint breaches. A higher proportion of ideal trajectories was achieved in the EM group. Therefore, we have shown that an EM IGS system can assist the spine surgeon in minimally invasive pedicle screw insertion by providing high-accuracy K-wire placement with a significant reduction in fluoroscopy time.

Original languageEnglish
JournalNeuroImage
Volume47
Issue numberSUPPL. 2
DOIs
Publication statusPublished - Aug 2009

Fingerprint

Electromagnetic Phenomena
Fluoroscopy
Computer-Assisted Surgery
Bone Wires
Zygapophyseal Joint
Cadaver
Spine
Tomography
Technology

ASJC Scopus subject areas

  • Cognitive Neuroscience
  • Neurology

Cite this

Electromagnetic navigation for percutaneous guide-wire insertion : Accuracy and efficiency compared to conventional fluoroscopic guidance. / von Jako, R. A.; Carrino, J. A.; Yonemura, K. S.; Noda, G. A.; Zhue, W.; Blaskiewicz, D.; Rajue, M.; Groszmann, D. E.; Wéber, G.

In: NeuroImage, Vol. 47, No. SUPPL. 2, 08.2009.

Research output: Contribution to journalArticle

von Jako, R. A. ; Carrino, J. A. ; Yonemura, K. S. ; Noda, G. A. ; Zhue, W. ; Blaskiewicz, D. ; Rajue, M. ; Groszmann, D. E. ; Wéber, G. / Electromagnetic navigation for percutaneous guide-wire insertion : Accuracy and efficiency compared to conventional fluoroscopic guidance. In: NeuroImage. 2009 ; Vol. 47, No. SUPPL. 2.
@article{695b874c75444cdf9aae23e3a6b2bdfe,
title = "Electromagnetic navigation for percutaneous guide-wire insertion: Accuracy and efficiency compared to conventional fluoroscopic guidance",
abstract = "The combination of electromagnetic (EM) navigation with intraoperative fluoroscopic images has the potential to create the ideal environment for spinal surgical applications. This technology enhances standard intraoperative fluoroscopic information for localization of the pedicle entry point and trajectory and may be an effective alternative to other image-guided surgery (IGS) systems. This study was performed to assess the accuracy and time efficiency (placement and fluoroscopy) using EM navigation versus conventional fluoroscopy in the placement of pedicle guide-wires. Kirschner wire (K-wire) placement was performed in cadavers from T8 to S1 using EM navigation versus conventional fluoroscopy. Time for set-up, placement, and fluoroscopy was recorded. After insertion, the accuracy for each level was assessed for the presence and location of facet joint, pedicle, or vertebral cortical perforation using computed tomography imaging with multiplanar reconstructions. K-wire placements were 100{\%} successful for both methods. Comparing EM-based IGS-assisted placement with the conventional fluoroscopy method showed a longer set-up time of 9.6 min versus 3.6 min, respectively. However, mean placement times of 6.3 min versus 9.7 min (P = 0.005) and mean fluoroscopy times of 11 s versus 48 s (P <0.0001) were both shorter for the EM group. There were no significant differences in the proportion of pedicle, vertebral body, or facet joint breaches. A higher proportion of ideal trajectories was achieved in the EM group. Therefore, we have shown that an EM IGS system can assist the spine surgeon in minimally invasive pedicle screw insertion by providing high-accuracy K-wire placement with a significant reduction in fluoroscopy time.",
author = "{von Jako}, {R. A.} and Carrino, {J. A.} and Yonemura, {K. S.} and Noda, {G. A.} and W. Zhue and D. Blaskiewicz and M. Rajue and Groszmann, {D. E.} and G. W{\'e}ber",
year = "2009",
month = "8",
doi = "10.1016/j.neuroimage.2009.05.002",
language = "English",
volume = "47",
journal = "NeuroImage",
issn = "1053-8119",
publisher = "Academic Press Inc.",
number = "SUPPL. 2",

}

TY - JOUR

T1 - Electromagnetic navigation for percutaneous guide-wire insertion

T2 - Accuracy and efficiency compared to conventional fluoroscopic guidance

AU - von Jako, R. A.

AU - Carrino, J. A.

AU - Yonemura, K. S.

AU - Noda, G. A.

AU - Zhue, W.

AU - Blaskiewicz, D.

AU - Rajue, M.

AU - Groszmann, D. E.

AU - Wéber, G.

PY - 2009/8

Y1 - 2009/8

N2 - The combination of electromagnetic (EM) navigation with intraoperative fluoroscopic images has the potential to create the ideal environment for spinal surgical applications. This technology enhances standard intraoperative fluoroscopic information for localization of the pedicle entry point and trajectory and may be an effective alternative to other image-guided surgery (IGS) systems. This study was performed to assess the accuracy and time efficiency (placement and fluoroscopy) using EM navigation versus conventional fluoroscopy in the placement of pedicle guide-wires. Kirschner wire (K-wire) placement was performed in cadavers from T8 to S1 using EM navigation versus conventional fluoroscopy. Time for set-up, placement, and fluoroscopy was recorded. After insertion, the accuracy for each level was assessed for the presence and location of facet joint, pedicle, or vertebral cortical perforation using computed tomography imaging with multiplanar reconstructions. K-wire placements were 100% successful for both methods. Comparing EM-based IGS-assisted placement with the conventional fluoroscopy method showed a longer set-up time of 9.6 min versus 3.6 min, respectively. However, mean placement times of 6.3 min versus 9.7 min (P = 0.005) and mean fluoroscopy times of 11 s versus 48 s (P <0.0001) were both shorter for the EM group. There were no significant differences in the proportion of pedicle, vertebral body, or facet joint breaches. A higher proportion of ideal trajectories was achieved in the EM group. Therefore, we have shown that an EM IGS system can assist the spine surgeon in minimally invasive pedicle screw insertion by providing high-accuracy K-wire placement with a significant reduction in fluoroscopy time.

AB - The combination of electromagnetic (EM) navigation with intraoperative fluoroscopic images has the potential to create the ideal environment for spinal surgical applications. This technology enhances standard intraoperative fluoroscopic information for localization of the pedicle entry point and trajectory and may be an effective alternative to other image-guided surgery (IGS) systems. This study was performed to assess the accuracy and time efficiency (placement and fluoroscopy) using EM navigation versus conventional fluoroscopy in the placement of pedicle guide-wires. Kirschner wire (K-wire) placement was performed in cadavers from T8 to S1 using EM navigation versus conventional fluoroscopy. Time for set-up, placement, and fluoroscopy was recorded. After insertion, the accuracy for each level was assessed for the presence and location of facet joint, pedicle, or vertebral cortical perforation using computed tomography imaging with multiplanar reconstructions. K-wire placements were 100% successful for both methods. Comparing EM-based IGS-assisted placement with the conventional fluoroscopy method showed a longer set-up time of 9.6 min versus 3.6 min, respectively. However, mean placement times of 6.3 min versus 9.7 min (P = 0.005) and mean fluoroscopy times of 11 s versus 48 s (P <0.0001) were both shorter for the EM group. There were no significant differences in the proportion of pedicle, vertebral body, or facet joint breaches. A higher proportion of ideal trajectories was achieved in the EM group. Therefore, we have shown that an EM IGS system can assist the spine surgeon in minimally invasive pedicle screw insertion by providing high-accuracy K-wire placement with a significant reduction in fluoroscopy time.

UR - http://www.scopus.com/inward/record.url?scp=67651163423&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=67651163423&partnerID=8YFLogxK

U2 - 10.1016/j.neuroimage.2009.05.002

DO - 10.1016/j.neuroimage.2009.05.002

M3 - Article

C2 - 19427905

AN - SCOPUS:67651163423

VL - 47

JO - NeuroImage

JF - NeuroImage

SN - 1053-8119

IS - SUPPL. 2

ER -