Effect of CO2 laser beam angle of incidence in the oral cavity.

L. Gáspár, M. Kásler, M. Orosz

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

In the oral cavity of white rats a series of experiments were made by CO 2 laser beam, by handpiece, micromanipulator, and an operation microscope. The authors examined the extent of the damaged tissue on the surface and in the depth of the wound. They established that in the case of 90 degrees angle of incidence--same power, exposition time and focus--the laser beam caused the deepest crater and the least damage to the surface. The decrease in the angle of incidence caused a decrease in the depth of the laser crater and increase in the surface. The 90 degrees angle of incidence CO 2 laser beam gives the optimal possibility for the precise elimination of the pathologic tissues on the surface and in the depth, without damaging the surrounding healthy structures. This operation not only protects the normal structures but also defends the physiological functions. In cases where it is not possible to apply the CO 2 laser beam at a minimum of an incidence of 60 degrees --the indirect way--the reflection has to be chosen. These aspects are important not only in the oral cavity but in other CO 2 laser operations.

Original languageEnglish
Pages (from-to)209-213
Number of pages5
JournalJournal of Clinical Laser Medicine and Surgery
Volume9
Issue number3
Publication statusPublished - Jun 1991

Fingerprint

Gas Lasers
Laser beams
Mouth
Lasers
Carbon Monoxide
Incidence
Micromanipulators
Tissue
Rats
Microscopes
Experiments
Wounds and Injuries

ASJC Scopus subject areas

  • Biomedical Engineering
  • Surgery

Cite this

Effect of CO2 laser beam angle of incidence in the oral cavity. / Gáspár, L.; Kásler, M.; Orosz, M.

In: Journal of Clinical Laser Medicine and Surgery, Vol. 9, No. 3, 06.1991, p. 209-213.

Research output: Contribution to journalArticle

@article{fbd1f954f798481888032d61116401b7,
title = "Effect of CO2 laser beam angle of incidence in the oral cavity.",
abstract = "In the oral cavity of white rats a series of experiments were made by CO 2 laser beam, by handpiece, micromanipulator, and an operation microscope. The authors examined the extent of the damaged tissue on the surface and in the depth of the wound. They established that in the case of 90 degrees angle of incidence--same power, exposition time and focus--the laser beam caused the deepest crater and the least damage to the surface. The decrease in the angle of incidence caused a decrease in the depth of the laser crater and increase in the surface. The 90 degrees angle of incidence CO 2 laser beam gives the optimal possibility for the precise elimination of the pathologic tissues on the surface and in the depth, without damaging the surrounding healthy structures. This operation not only protects the normal structures but also defends the physiological functions. In cases where it is not possible to apply the CO 2 laser beam at a minimum of an incidence of 60 degrees --the indirect way--the reflection has to be chosen. These aspects are important not only in the oral cavity but in other CO 2 laser operations.",
author = "L. G{\'a}sp{\'a}r and M. K{\'a}sler and M. Orosz",
year = "1991",
month = "6",
language = "English",
volume = "9",
pages = "209--213",
journal = "Photomedicine and Laser Surgery",
issn = "1549-5418",
publisher = "Mary Ann Liebert Inc.",
number = "3",

}

TY - JOUR

T1 - Effect of CO2 laser beam angle of incidence in the oral cavity.

AU - Gáspár, L.

AU - Kásler, M.

AU - Orosz, M.

PY - 1991/6

Y1 - 1991/6

N2 - In the oral cavity of white rats a series of experiments were made by CO 2 laser beam, by handpiece, micromanipulator, and an operation microscope. The authors examined the extent of the damaged tissue on the surface and in the depth of the wound. They established that in the case of 90 degrees angle of incidence--same power, exposition time and focus--the laser beam caused the deepest crater and the least damage to the surface. The decrease in the angle of incidence caused a decrease in the depth of the laser crater and increase in the surface. The 90 degrees angle of incidence CO 2 laser beam gives the optimal possibility for the precise elimination of the pathologic tissues on the surface and in the depth, without damaging the surrounding healthy structures. This operation not only protects the normal structures but also defends the physiological functions. In cases where it is not possible to apply the CO 2 laser beam at a minimum of an incidence of 60 degrees --the indirect way--the reflection has to be chosen. These aspects are important not only in the oral cavity but in other CO 2 laser operations.

AB - In the oral cavity of white rats a series of experiments were made by CO 2 laser beam, by handpiece, micromanipulator, and an operation microscope. The authors examined the extent of the damaged tissue on the surface and in the depth of the wound. They established that in the case of 90 degrees angle of incidence--same power, exposition time and focus--the laser beam caused the deepest crater and the least damage to the surface. The decrease in the angle of incidence caused a decrease in the depth of the laser crater and increase in the surface. The 90 degrees angle of incidence CO 2 laser beam gives the optimal possibility for the precise elimination of the pathologic tissues on the surface and in the depth, without damaging the surrounding healthy structures. This operation not only protects the normal structures but also defends the physiological functions. In cases where it is not possible to apply the CO 2 laser beam at a minimum of an incidence of 60 degrees --the indirect way--the reflection has to be chosen. These aspects are important not only in the oral cavity but in other CO 2 laser operations.

UR - http://www.scopus.com/inward/record.url?scp=0026168427&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026168427&partnerID=8YFLogxK

M3 - Article

C2 - 10149459

AN - SCOPUS:0026168427

VL - 9

SP - 209

EP - 213

JO - Photomedicine and Laser Surgery

JF - Photomedicine and Laser Surgery