Dual-channel photoacoustic hygrometer for airborne measurements: Background, calibration, laboratory and in-flight intercomparison tests

D. Tátrai, Z. Bozóki, H. Smit, C. Rolf, N. Spelten, M. Krämer, A. Filges, C. Gerbig, G. Gulyás, G. Szabó

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

This paper describes a tunable diode laser-based dual-channel photoacoustic (PA) humidity measuring system primarily designed for aircraft-based environment research. It is calibrated for total pressure and water vapor (WV) volume mixing ratios (VMRs) possible during airborne applications. WV VMR is calculated by using pressure-dependent calibration curves and a cubic spline interpolation method. Coverage of the entire atmospheric humidity concentration range that might be encountered during airborne measurements is facilitated by applying an automated sensitivity mode switching algorithm. The calibrated PA system was validated through laboratory and airborne intercomparisons, which proved that the repeatability, the estimated accuracy and the response time of the system are 0.5 ppmV or 0.5% of the actual reading (whichever value is the greater), 5% of the actual reading within the VMR range of 1-12 000 ppmV and 2 s, respectively. The upper detection limit of the system is theoretically about 85 000 ppmV, limited only by condensation of water vapor on the walls of the 318 K heated PA cells and inlet lines, and was experimentally verified up to 20 000 ppmV. The unique advantage of the presented system is its applicability for simultaneous water vapor and total water volume mixing ratio measurements.

Original languageEnglish
Pages (from-to)33-42
Number of pages10
JournalAtmospheric Measurement Techniques
Volume8
Issue number1
DOIs
Publication statusPublished - Jan 6 2015

Fingerprint

mixing ratio
water vapor
flight
calibration
interpolation
condensation
humidity
aircraft
laser
test
laboratory
water

ASJC Scopus subject areas

  • Atmospheric Science

Cite this

Dual-channel photoacoustic hygrometer for airborne measurements : Background, calibration, laboratory and in-flight intercomparison tests. / Tátrai, D.; Bozóki, Z.; Smit, H.; Rolf, C.; Spelten, N.; Krämer, M.; Filges, A.; Gerbig, C.; Gulyás, G.; Szabó, G.

In: Atmospheric Measurement Techniques, Vol. 8, No. 1, 06.01.2015, p. 33-42.

Research output: Contribution to journalArticle

Tátrai, D. ; Bozóki, Z. ; Smit, H. ; Rolf, C. ; Spelten, N. ; Krämer, M. ; Filges, A. ; Gerbig, C. ; Gulyás, G. ; Szabó, G. / Dual-channel photoacoustic hygrometer for airborne measurements : Background, calibration, laboratory and in-flight intercomparison tests. In: Atmospheric Measurement Techniques. 2015 ; Vol. 8, No. 1. pp. 33-42.
@article{318c3b0172d34dbf8e8e9e722b23af82,
title = "Dual-channel photoacoustic hygrometer for airborne measurements: Background, calibration, laboratory and in-flight intercomparison tests",
abstract = "This paper describes a tunable diode laser-based dual-channel photoacoustic (PA) humidity measuring system primarily designed for aircraft-based environment research. It is calibrated for total pressure and water vapor (WV) volume mixing ratios (VMRs) possible during airborne applications. WV VMR is calculated by using pressure-dependent calibration curves and a cubic spline interpolation method. Coverage of the entire atmospheric humidity concentration range that might be encountered during airborne measurements is facilitated by applying an automated sensitivity mode switching algorithm. The calibrated PA system was validated through laboratory and airborne intercomparisons, which proved that the repeatability, the estimated accuracy and the response time of the system are 0.5 ppmV or 0.5{\%} of the actual reading (whichever value is the greater), 5{\%} of the actual reading within the VMR range of 1-12 000 ppmV and 2 s, respectively. The upper detection limit of the system is theoretically about 85 000 ppmV, limited only by condensation of water vapor on the walls of the 318 K heated PA cells and inlet lines, and was experimentally verified up to 20 000 ppmV. The unique advantage of the presented system is its applicability for simultaneous water vapor and total water volume mixing ratio measurements.",
author = "D. T{\'a}trai and Z. Boz{\'o}ki and H. Smit and C. Rolf and N. Spelten and M. Kr{\"a}mer and A. Filges and C. Gerbig and G. Guly{\'a}s and G. Szab{\'o}",
year = "2015",
month = "1",
day = "6",
doi = "10.5194/amt-8-33-2015",
language = "English",
volume = "8",
pages = "33--42",
journal = "Atmospheric Measurement Techniques",
issn = "1867-1381",
publisher = "Copernicus Gesellschaft mbH",
number = "1",

}

TY - JOUR

T1 - Dual-channel photoacoustic hygrometer for airborne measurements

T2 - Background, calibration, laboratory and in-flight intercomparison tests

AU - Tátrai, D.

AU - Bozóki, Z.

AU - Smit, H.

AU - Rolf, C.

AU - Spelten, N.

AU - Krämer, M.

AU - Filges, A.

AU - Gerbig, C.

AU - Gulyás, G.

AU - Szabó, G.

PY - 2015/1/6

Y1 - 2015/1/6

N2 - This paper describes a tunable diode laser-based dual-channel photoacoustic (PA) humidity measuring system primarily designed for aircraft-based environment research. It is calibrated for total pressure and water vapor (WV) volume mixing ratios (VMRs) possible during airborne applications. WV VMR is calculated by using pressure-dependent calibration curves and a cubic spline interpolation method. Coverage of the entire atmospheric humidity concentration range that might be encountered during airborne measurements is facilitated by applying an automated sensitivity mode switching algorithm. The calibrated PA system was validated through laboratory and airborne intercomparisons, which proved that the repeatability, the estimated accuracy and the response time of the system are 0.5 ppmV or 0.5% of the actual reading (whichever value is the greater), 5% of the actual reading within the VMR range of 1-12 000 ppmV and 2 s, respectively. The upper detection limit of the system is theoretically about 85 000 ppmV, limited only by condensation of water vapor on the walls of the 318 K heated PA cells and inlet lines, and was experimentally verified up to 20 000 ppmV. The unique advantage of the presented system is its applicability for simultaneous water vapor and total water volume mixing ratio measurements.

AB - This paper describes a tunable diode laser-based dual-channel photoacoustic (PA) humidity measuring system primarily designed for aircraft-based environment research. It is calibrated for total pressure and water vapor (WV) volume mixing ratios (VMRs) possible during airborne applications. WV VMR is calculated by using pressure-dependent calibration curves and a cubic spline interpolation method. Coverage of the entire atmospheric humidity concentration range that might be encountered during airborne measurements is facilitated by applying an automated sensitivity mode switching algorithm. The calibrated PA system was validated through laboratory and airborne intercomparisons, which proved that the repeatability, the estimated accuracy and the response time of the system are 0.5 ppmV or 0.5% of the actual reading (whichever value is the greater), 5% of the actual reading within the VMR range of 1-12 000 ppmV and 2 s, respectively. The upper detection limit of the system is theoretically about 85 000 ppmV, limited only by condensation of water vapor on the walls of the 318 K heated PA cells and inlet lines, and was experimentally verified up to 20 000 ppmV. The unique advantage of the presented system is its applicability for simultaneous water vapor and total water volume mixing ratio measurements.

UR - http://www.scopus.com/inward/record.url?scp=84920746950&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84920746950&partnerID=8YFLogxK

U2 - 10.5194/amt-8-33-2015

DO - 10.5194/amt-8-33-2015

M3 - Article

AN - SCOPUS:84920746950

VL - 8

SP - 33

EP - 42

JO - Atmospheric Measurement Techniques

JF - Atmospheric Measurement Techniques

SN - 1867-1381

IS - 1

ER -