Dosimetric properties of gammaand electron-irradiated commercial window glasses

Piergiorgio Fuochi, Ugo Corda, Marco Lavalle, A. Kovács, Marika Baranyai, Arbi Mejri, Khaled Farah

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

Two different types of window glasses have been investigated as possible routine dosimeters in the range of 1-50 kGy. Glass samples were irradiated with 3.4 MeV and 8.4 MeV electron beams and the results compared with those obtained by 60Co γ irradiation. Due to the strong optical absorption at wavelengths <310 nm, even at low doses, optical measurements were limited to the range 320-700 nm. In both types of glasses, irradiation induced two absorption bands around 410 and 600 nm the intensities of which are proportional to dose; the 600 nm band being less sensitive to radiation. These bands have been attributed to non bridging oxygen hole centres existing in two different configurations. Because of the rapid fading of the optical absorbance observed at room temperature immediately after irradiation (> 15% in two days), the samples underwent a post-irradiation thermal treatment (150°C for 20 min) to improve the stability of absorbance. The fading characteristics of the irradiated and thermally treated glasses, kept in the dark at room temperature, were studied for several weeks. A fast decay, whose intensity depends on the type and energy of the ionizing radiation, was observed for few days after irradiation and thermal treatment, followed by a much slower decay. The results show that this kind of material could be used as routine dosimeters within a certain dose range, as long as proper calibrations are made for each batch of glass and the appropriate precautions are taken when doing calibration and performing routine dosimetry.

Original languageEnglish
Pages (from-to)39-43
Number of pages5
JournalNukleonika
Volume54
Issue number1
Publication statusPublished - 2009

Fingerprint

glass
dosimeters
Glass
electron
irradiation
Electrons
Dosimeters
Irradiation
Dosimetry
electrons
Heat treatment
Calibration
calibration
accident prevention
Ionizing radiation
decay
fading
absorbance
ionizing radiation
Light absorption

Keywords

  • Dosimeter
  • Electron beam
  • Fading behaviour
  • Gamma rays
  • Optical absorption
  • Silicate glass

ASJC Scopus subject areas

  • Nuclear Energy and Engineering
  • Safety, Risk, Reliability and Quality
  • Waste Management and Disposal
  • Condensed Matter Physics
  • Instrumentation
  • Nuclear and High Energy Physics

Cite this

Fuochi, P., Corda, U., Lavalle, M., Kovács, A., Baranyai, M., Mejri, A., & Farah, K. (2009). Dosimetric properties of gammaand electron-irradiated commercial window glasses. Nukleonika, 54(1), 39-43.

Dosimetric properties of gammaand electron-irradiated commercial window glasses. / Fuochi, Piergiorgio; Corda, Ugo; Lavalle, Marco; Kovács, A.; Baranyai, Marika; Mejri, Arbi; Farah, Khaled.

In: Nukleonika, Vol. 54, No. 1, 2009, p. 39-43.

Research output: Contribution to journalArticle

Fuochi, P, Corda, U, Lavalle, M, Kovács, A, Baranyai, M, Mejri, A & Farah, K 2009, 'Dosimetric properties of gammaand electron-irradiated commercial window glasses', Nukleonika, vol. 54, no. 1, pp. 39-43.
Fuochi P, Corda U, Lavalle M, Kovács A, Baranyai M, Mejri A et al. Dosimetric properties of gammaand electron-irradiated commercial window glasses. Nukleonika. 2009;54(1):39-43.
Fuochi, Piergiorgio ; Corda, Ugo ; Lavalle, Marco ; Kovács, A. ; Baranyai, Marika ; Mejri, Arbi ; Farah, Khaled. / Dosimetric properties of gammaand electron-irradiated commercial window glasses. In: Nukleonika. 2009 ; Vol. 54, No. 1. pp. 39-43.
@article{df1a5544185f459fba436b4e9254d732,
title = "Dosimetric properties of gammaand electron-irradiated commercial window glasses",
abstract = "Two different types of window glasses have been investigated as possible routine dosimeters in the range of 1-50 kGy. Glass samples were irradiated with 3.4 MeV and 8.4 MeV electron beams and the results compared with those obtained by 60Co γ irradiation. Due to the strong optical absorption at wavelengths <310 nm, even at low doses, optical measurements were limited to the range 320-700 nm. In both types of glasses, irradiation induced two absorption bands around 410 and 600 nm the intensities of which are proportional to dose; the 600 nm band being less sensitive to radiation. These bands have been attributed to non bridging oxygen hole centres existing in two different configurations. Because of the rapid fading of the optical absorbance observed at room temperature immediately after irradiation (> 15{\%} in two days), the samples underwent a post-irradiation thermal treatment (150°C for 20 min) to improve the stability of absorbance. The fading characteristics of the irradiated and thermally treated glasses, kept in the dark at room temperature, were studied for several weeks. A fast decay, whose intensity depends on the type and energy of the ionizing radiation, was observed for few days after irradiation and thermal treatment, followed by a much slower decay. The results show that this kind of material could be used as routine dosimeters within a certain dose range, as long as proper calibrations are made for each batch of glass and the appropriate precautions are taken when doing calibration and performing routine dosimetry.",
keywords = "Dosimeter, Electron beam, Fading behaviour, Gamma rays, Optical absorption, Silicate glass",
author = "Piergiorgio Fuochi and Ugo Corda and Marco Lavalle and A. Kov{\'a}cs and Marika Baranyai and Arbi Mejri and Khaled Farah",
year = "2009",
language = "English",
volume = "54",
pages = "39--43",
journal = "Nukleonika",
issn = "0029-5922",
publisher = "Institute of Nuclear Chemistry and Technology",
number = "1",

}

TY - JOUR

T1 - Dosimetric properties of gammaand electron-irradiated commercial window glasses

AU - Fuochi, Piergiorgio

AU - Corda, Ugo

AU - Lavalle, Marco

AU - Kovács, A.

AU - Baranyai, Marika

AU - Mejri, Arbi

AU - Farah, Khaled

PY - 2009

Y1 - 2009

N2 - Two different types of window glasses have been investigated as possible routine dosimeters in the range of 1-50 kGy. Glass samples were irradiated with 3.4 MeV and 8.4 MeV electron beams and the results compared with those obtained by 60Co γ irradiation. Due to the strong optical absorption at wavelengths <310 nm, even at low doses, optical measurements were limited to the range 320-700 nm. In both types of glasses, irradiation induced two absorption bands around 410 and 600 nm the intensities of which are proportional to dose; the 600 nm band being less sensitive to radiation. These bands have been attributed to non bridging oxygen hole centres existing in two different configurations. Because of the rapid fading of the optical absorbance observed at room temperature immediately after irradiation (> 15% in two days), the samples underwent a post-irradiation thermal treatment (150°C for 20 min) to improve the stability of absorbance. The fading characteristics of the irradiated and thermally treated glasses, kept in the dark at room temperature, were studied for several weeks. A fast decay, whose intensity depends on the type and energy of the ionizing radiation, was observed for few days after irradiation and thermal treatment, followed by a much slower decay. The results show that this kind of material could be used as routine dosimeters within a certain dose range, as long as proper calibrations are made for each batch of glass and the appropriate precautions are taken when doing calibration and performing routine dosimetry.

AB - Two different types of window glasses have been investigated as possible routine dosimeters in the range of 1-50 kGy. Glass samples were irradiated with 3.4 MeV and 8.4 MeV electron beams and the results compared with those obtained by 60Co γ irradiation. Due to the strong optical absorption at wavelengths <310 nm, even at low doses, optical measurements were limited to the range 320-700 nm. In both types of glasses, irradiation induced two absorption bands around 410 and 600 nm the intensities of which are proportional to dose; the 600 nm band being less sensitive to radiation. These bands have been attributed to non bridging oxygen hole centres existing in two different configurations. Because of the rapid fading of the optical absorbance observed at room temperature immediately after irradiation (> 15% in two days), the samples underwent a post-irradiation thermal treatment (150°C for 20 min) to improve the stability of absorbance. The fading characteristics of the irradiated and thermally treated glasses, kept in the dark at room temperature, were studied for several weeks. A fast decay, whose intensity depends on the type and energy of the ionizing radiation, was observed for few days after irradiation and thermal treatment, followed by a much slower decay. The results show that this kind of material could be used as routine dosimeters within a certain dose range, as long as proper calibrations are made for each batch of glass and the appropriate precautions are taken when doing calibration and performing routine dosimetry.

KW - Dosimeter

KW - Electron beam

KW - Fading behaviour

KW - Gamma rays

KW - Optical absorption

KW - Silicate glass

UR - http://www.scopus.com/inward/record.url?scp=76449095980&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=76449095980&partnerID=8YFLogxK

M3 - Article

VL - 54

SP - 39

EP - 43

JO - Nukleonika

JF - Nukleonika

SN - 0029-5922

IS - 1

ER -