Distribution of indoor radon concentrations between selected Hungarian thermal baths

Amin Shahrokhi, Erika Nagy, Anita Csordás, J. Somlai, T. Kovács

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Owing to the high potential of radon to increase the risk of lung cancer, health organizations are enforced to update their regulations and recommendations regarding indoor radon levels each year. In this study, the indoor radon concentrations of three randomly selected thermal baths in Hungary using CR-39 and an AlphaGUARD radon monitor were measured with regard to the new updated standards of the European Basic Safety Standard (EU BSS, Council Directive 2013/59/Euratom, 2014). The annual average of indoor radon concentrations in Parad Medical Bath, Igal Health Spa and Eger Turkish Bath were measured as 159 ± 19, 176 ± 27 and 301 ± 30 Bq/m3, respectively. Indoor radon concentration in all measurement locations were determined to be below the reference level, with the exception of the main pool, small pool and sparkling bath areas in the Eger Turkish Bath that were measured as 403 ± 42, 315 ± 32 and 354 ± 36 Bq/m3, respectively. In light of the results, the estimated annual average radon concentration in the thermal baths was below the EU BSS reference level of 300 Bq/m3. Personal dosimetry is required to estimate the annual effective dose from inhaled radon by the workers at the Eger Turkish Bath. This procedure is required in order to justify the application of the mitigation process of decreasing working hours, improving the ventilation rate or increasing the number of classified employees in response to the official radiation surveillance programme.

Original languageEnglish
Pages (from-to)333-336
Number of pages4
JournalNukleonika
Volume61
Issue number3
DOIs
Publication statusPublished - 2016

Fingerprint

indoor radon
Radon
radon
baths
Blind source separation
Dosimetry
ventilation
health
cancer
mitigation
Health
Hungary
distribution
Hot Temperature
surveillance
recommendations
lungs
Ventilation
dosimeters
monitors

Keywords

  • AlphaGUARD
  • CR-39
  • EU BSS
  • Hungary
  • Radon
  • Thermal bath

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Nuclear Energy and Engineering
  • Instrumentation
  • Condensed Matter Physics
  • Safety, Risk, Reliability and Quality
  • Waste Management and Disposal

Cite this

Distribution of indoor radon concentrations between selected Hungarian thermal baths. / Shahrokhi, Amin; Nagy, Erika; Csordás, Anita; Somlai, J.; Kovács, T.

In: Nukleonika, Vol. 61, No. 3, 2016, p. 333-336.

Research output: Contribution to journalArticle

Shahrokhi, Amin ; Nagy, Erika ; Csordás, Anita ; Somlai, J. ; Kovács, T. / Distribution of indoor radon concentrations between selected Hungarian thermal baths. In: Nukleonika. 2016 ; Vol. 61, No. 3. pp. 333-336.
@article{4eaea494818f40628f7320a4b52a47e8,
title = "Distribution of indoor radon concentrations between selected Hungarian thermal baths",
abstract = "Owing to the high potential of radon to increase the risk of lung cancer, health organizations are enforced to update their regulations and recommendations regarding indoor radon levels each year. In this study, the indoor radon concentrations of three randomly selected thermal baths in Hungary using CR-39 and an AlphaGUARD radon monitor were measured with regard to the new updated standards of the European Basic Safety Standard (EU BSS, Council Directive 2013/59/Euratom, 2014). The annual average of indoor radon concentrations in Parad Medical Bath, Igal Health Spa and Eger Turkish Bath were measured as 159 ± 19, 176 ± 27 and 301 ± 30 Bq/m3, respectively. Indoor radon concentration in all measurement locations were determined to be below the reference level, with the exception of the main pool, small pool and sparkling bath areas in the Eger Turkish Bath that were measured as 403 ± 42, 315 ± 32 and 354 ± 36 Bq/m3, respectively. In light of the results, the estimated annual average radon concentration in the thermal baths was below the EU BSS reference level of 300 Bq/m3. Personal dosimetry is required to estimate the annual effective dose from inhaled radon by the workers at the Eger Turkish Bath. This procedure is required in order to justify the application of the mitigation process of decreasing working hours, improving the ventilation rate or increasing the number of classified employees in response to the official radiation surveillance programme.",
keywords = "AlphaGUARD, CR-39, EU BSS, Hungary, Radon, Thermal bath",
author = "Amin Shahrokhi and Erika Nagy and Anita Csord{\'a}s and J. Somlai and T. Kov{\'a}cs",
year = "2016",
doi = "10.1515/nuka-2016-0055",
language = "English",
volume = "61",
pages = "333--336",
journal = "Nukleonika",
issn = "0029-5922",
publisher = "Institute of Nuclear Chemistry and Technology",
number = "3",

}

TY - JOUR

T1 - Distribution of indoor radon concentrations between selected Hungarian thermal baths

AU - Shahrokhi, Amin

AU - Nagy, Erika

AU - Csordás, Anita

AU - Somlai, J.

AU - Kovács, T.

PY - 2016

Y1 - 2016

N2 - Owing to the high potential of radon to increase the risk of lung cancer, health organizations are enforced to update their regulations and recommendations regarding indoor radon levels each year. In this study, the indoor radon concentrations of three randomly selected thermal baths in Hungary using CR-39 and an AlphaGUARD radon monitor were measured with regard to the new updated standards of the European Basic Safety Standard (EU BSS, Council Directive 2013/59/Euratom, 2014). The annual average of indoor radon concentrations in Parad Medical Bath, Igal Health Spa and Eger Turkish Bath were measured as 159 ± 19, 176 ± 27 and 301 ± 30 Bq/m3, respectively. Indoor radon concentration in all measurement locations were determined to be below the reference level, with the exception of the main pool, small pool and sparkling bath areas in the Eger Turkish Bath that were measured as 403 ± 42, 315 ± 32 and 354 ± 36 Bq/m3, respectively. In light of the results, the estimated annual average radon concentration in the thermal baths was below the EU BSS reference level of 300 Bq/m3. Personal dosimetry is required to estimate the annual effective dose from inhaled radon by the workers at the Eger Turkish Bath. This procedure is required in order to justify the application of the mitigation process of decreasing working hours, improving the ventilation rate or increasing the number of classified employees in response to the official radiation surveillance programme.

AB - Owing to the high potential of radon to increase the risk of lung cancer, health organizations are enforced to update their regulations and recommendations regarding indoor radon levels each year. In this study, the indoor radon concentrations of three randomly selected thermal baths in Hungary using CR-39 and an AlphaGUARD radon monitor were measured with regard to the new updated standards of the European Basic Safety Standard (EU BSS, Council Directive 2013/59/Euratom, 2014). The annual average of indoor radon concentrations in Parad Medical Bath, Igal Health Spa and Eger Turkish Bath were measured as 159 ± 19, 176 ± 27 and 301 ± 30 Bq/m3, respectively. Indoor radon concentration in all measurement locations were determined to be below the reference level, with the exception of the main pool, small pool and sparkling bath areas in the Eger Turkish Bath that were measured as 403 ± 42, 315 ± 32 and 354 ± 36 Bq/m3, respectively. In light of the results, the estimated annual average radon concentration in the thermal baths was below the EU BSS reference level of 300 Bq/m3. Personal dosimetry is required to estimate the annual effective dose from inhaled radon by the workers at the Eger Turkish Bath. This procedure is required in order to justify the application of the mitigation process of decreasing working hours, improving the ventilation rate or increasing the number of classified employees in response to the official radiation surveillance programme.

KW - AlphaGUARD

KW - CR-39

KW - EU BSS

KW - Hungary

KW - Radon

KW - Thermal bath

UR - http://www.scopus.com/inward/record.url?scp=84990060532&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84990060532&partnerID=8YFLogxK

U2 - 10.1515/nuka-2016-0055

DO - 10.1515/nuka-2016-0055

M3 - Article

VL - 61

SP - 333

EP - 336

JO - Nukleonika

JF - Nukleonika

SN - 0029-5922

IS - 3

ER -