Dimensional characterization of gold nanorods by combining millisecond and microsecond temporal resolution single particle ICP-MS measurements

Ildikó Kálomista, Albert Kéri, Ditta Ungor, Edit Csapó, I. Dékány, Thomas Prohaska, G. Galbács

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

A systematic investigation of single particle inductively coupled plasma mass spectrometry (spICP-MS) signal profiles recorded with normal (ms-range) and high (μs-range) temporal resolution for spherical and rod-shaped gold nanoparticles was performed. The experiments with nanorods were carried out on hemispherically capped cylindrical particles synthesized in the aspect ratio range from 1.5 to 4.5. A comparison of NP signals and time profiles for spherical and rod-shaped NPs revealed that (i) the volume of the particles can be assessed by conventional spICP-MS measurements using a joint, linear calibration plot; and (ii) the shape of signal time profiles and transit times for equal-volume spherical and rod-shaped NPs are different, based on which the aspect ratio can be calculated. By using the statistical evaluation of the high resolution signal time profiles, an analytical method was developed for the discrimination and dimensional analysis of nanorod-shaped NPs. The method is based on observing the shortest and longest transit times for nanoparticles. In the case of spherical NPs, these transit times are very similar, whereas in the case of nanorods, the shortest and longest transit times correlate with the characteristic width and length of the particles, respectively. This method is the first nanorod dimensional characterization method in the literature, which is based solely on ICP-MS measurements. It was shown that the accuracy of the method is very good-the characteristic length and width of the particles could be determined with less than 6% error.

Original languageEnglish
Pages (from-to)2455-2462
Number of pages8
JournalJournal of Analytical Atomic Spectrometry
Volume32
Issue number12
DOIs
Publication statusPublished - Dec 1 2017

Fingerprint

Inductively coupled plasma
Nanorods
Gold
Inductively coupled plasma mass spectrometry
Aspect ratio
Nanoparticles
Calibration
Experiments

ASJC Scopus subject areas

  • Analytical Chemistry
  • Spectroscopy

Cite this

Dimensional characterization of gold nanorods by combining millisecond and microsecond temporal resolution single particle ICP-MS measurements. / Kálomista, Ildikó; Kéri, Albert; Ungor, Ditta; Csapó, Edit; Dékány, I.; Prohaska, Thomas; Galbács, G.

In: Journal of Analytical Atomic Spectrometry, Vol. 32, No. 12, 01.12.2017, p. 2455-2462.

Research output: Contribution to journalArticle

@article{42c06bc1bb49420d9f56e4c2a0f18ef9,
title = "Dimensional characterization of gold nanorods by combining millisecond and microsecond temporal resolution single particle ICP-MS measurements",
abstract = "A systematic investigation of single particle inductively coupled plasma mass spectrometry (spICP-MS) signal profiles recorded with normal (ms-range) and high (μs-range) temporal resolution for spherical and rod-shaped gold nanoparticles was performed. The experiments with nanorods were carried out on hemispherically capped cylindrical particles synthesized in the aspect ratio range from 1.5 to 4.5. A comparison of NP signals and time profiles for spherical and rod-shaped NPs revealed that (i) the volume of the particles can be assessed by conventional spICP-MS measurements using a joint, linear calibration plot; and (ii) the shape of signal time profiles and transit times for equal-volume spherical and rod-shaped NPs are different, based on which the aspect ratio can be calculated. By using the statistical evaluation of the high resolution signal time profiles, an analytical method was developed for the discrimination and dimensional analysis of nanorod-shaped NPs. The method is based on observing the shortest and longest transit times for nanoparticles. In the case of spherical NPs, these transit times are very similar, whereas in the case of nanorods, the shortest and longest transit times correlate with the characteristic width and length of the particles, respectively. This method is the first nanorod dimensional characterization method in the literature, which is based solely on ICP-MS measurements. It was shown that the accuracy of the method is very good-the characteristic length and width of the particles could be determined with less than 6{\%} error.",
author = "Ildik{\'o} K{\'a}lomista and Albert K{\'e}ri and Ditta Ungor and Edit Csap{\'o} and I. D{\'e}k{\'a}ny and Thomas Prohaska and G. Galb{\'a}cs",
year = "2017",
month = "12",
day = "1",
doi = "10.1039/c7ja00306d",
language = "English",
volume = "32",
pages = "2455--2462",
journal = "Journal of Analytical Atomic Spectrometry",
issn = "0267-9477",
publisher = "Royal Society of Chemistry",
number = "12",

}

TY - JOUR

T1 - Dimensional characterization of gold nanorods by combining millisecond and microsecond temporal resolution single particle ICP-MS measurements

AU - Kálomista, Ildikó

AU - Kéri, Albert

AU - Ungor, Ditta

AU - Csapó, Edit

AU - Dékány, I.

AU - Prohaska, Thomas

AU - Galbács, G.

PY - 2017/12/1

Y1 - 2017/12/1

N2 - A systematic investigation of single particle inductively coupled plasma mass spectrometry (spICP-MS) signal profiles recorded with normal (ms-range) and high (μs-range) temporal resolution for spherical and rod-shaped gold nanoparticles was performed. The experiments with nanorods were carried out on hemispherically capped cylindrical particles synthesized in the aspect ratio range from 1.5 to 4.5. A comparison of NP signals and time profiles for spherical and rod-shaped NPs revealed that (i) the volume of the particles can be assessed by conventional spICP-MS measurements using a joint, linear calibration plot; and (ii) the shape of signal time profiles and transit times for equal-volume spherical and rod-shaped NPs are different, based on which the aspect ratio can be calculated. By using the statistical evaluation of the high resolution signal time profiles, an analytical method was developed for the discrimination and dimensional analysis of nanorod-shaped NPs. The method is based on observing the shortest and longest transit times for nanoparticles. In the case of spherical NPs, these transit times are very similar, whereas in the case of nanorods, the shortest and longest transit times correlate with the characteristic width and length of the particles, respectively. This method is the first nanorod dimensional characterization method in the literature, which is based solely on ICP-MS measurements. It was shown that the accuracy of the method is very good-the characteristic length and width of the particles could be determined with less than 6% error.

AB - A systematic investigation of single particle inductively coupled plasma mass spectrometry (spICP-MS) signal profiles recorded with normal (ms-range) and high (μs-range) temporal resolution for spherical and rod-shaped gold nanoparticles was performed. The experiments with nanorods were carried out on hemispherically capped cylindrical particles synthesized in the aspect ratio range from 1.5 to 4.5. A comparison of NP signals and time profiles for spherical and rod-shaped NPs revealed that (i) the volume of the particles can be assessed by conventional spICP-MS measurements using a joint, linear calibration plot; and (ii) the shape of signal time profiles and transit times for equal-volume spherical and rod-shaped NPs are different, based on which the aspect ratio can be calculated. By using the statistical evaluation of the high resolution signal time profiles, an analytical method was developed for the discrimination and dimensional analysis of nanorod-shaped NPs. The method is based on observing the shortest and longest transit times for nanoparticles. In the case of spherical NPs, these transit times are very similar, whereas in the case of nanorods, the shortest and longest transit times correlate with the characteristic width and length of the particles, respectively. This method is the first nanorod dimensional characterization method in the literature, which is based solely on ICP-MS measurements. It was shown that the accuracy of the method is very good-the characteristic length and width of the particles could be determined with less than 6% error.

UR - http://www.scopus.com/inward/record.url?scp=85036456282&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85036456282&partnerID=8YFLogxK

U2 - 10.1039/c7ja00306d

DO - 10.1039/c7ja00306d

M3 - Article

AN - SCOPUS:85036456282

VL - 32

SP - 2455

EP - 2462

JO - Journal of Analytical Atomic Spectrometry

JF - Journal of Analytical Atomic Spectrometry

SN - 0267-9477

IS - 12

ER -