Dilatometric measurement on Al-Mg-Si alloys

J. Major, E. Nagy, G. Tichy

Research output: Contribution to journalArticle

Abstract

After a treatment of homogenisation Al-Mg-Si samples were quenched into water of room temperature and placed immediately into the measuring head of a dilatometer, which measured the isothermal change of length in 30-160°C range. The observed relative change of length within 6 hours was found to be in the order of 10-5.

Original languageEnglish
Pages (from-to)105-109
Number of pages5
JournalActa Physica Academiae Scientiarum Hungaricae
Volume40
Issue number2
DOIs
Publication statusPublished - Feb 1976

Fingerprint

extensometers
homogenizing
room temperature
water

ASJC Scopus subject areas

  • Nuclear and High Energy Physics

Cite this

Dilatometric measurement on Al-Mg-Si alloys. / Major, J.; Nagy, E.; Tichy, G.

In: Acta Physica Academiae Scientiarum Hungaricae, Vol. 40, No. 2, 02.1976, p. 105-109.

Research output: Contribution to journalArticle

@article{fe898786d83e4cdba6207b56a423dfd0,
title = "Dilatometric measurement on Al-Mg-Si alloys",
abstract = "After a treatment of homogenisation Al-Mg-Si samples were quenched into water of room temperature and placed immediately into the measuring head of a dilatometer, which measured the isothermal change of length in 30-160°C range. The observed relative change of length within 6 hours was found to be in the order of 10-5.",
author = "J. Major and E. Nagy and G. Tichy",
year = "1976",
month = "2",
doi = "10.1007/BF03157093",
language = "English",
volume = "40",
pages = "105--109",
journal = "Acta Physica Academiae Scientiarum Hungaricae",
issn = "0001-6705",
publisher = "Akademiai Kiado",
number = "2",

}

TY - JOUR

T1 - Dilatometric measurement on Al-Mg-Si alloys

AU - Major, J.

AU - Nagy, E.

AU - Tichy, G.

PY - 1976/2

Y1 - 1976/2

N2 - After a treatment of homogenisation Al-Mg-Si samples were quenched into water of room temperature and placed immediately into the measuring head of a dilatometer, which measured the isothermal change of length in 30-160°C range. The observed relative change of length within 6 hours was found to be in the order of 10-5.

AB - After a treatment of homogenisation Al-Mg-Si samples were quenched into water of room temperature and placed immediately into the measuring head of a dilatometer, which measured the isothermal change of length in 30-160°C range. The observed relative change of length within 6 hours was found to be in the order of 10-5.

UR - http://www.scopus.com/inward/record.url?scp=77951514372&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77951514372&partnerID=8YFLogxK

U2 - 10.1007/BF03157093

DO - 10.1007/BF03157093

M3 - Article

AN - SCOPUS:77951514372

VL - 40

SP - 105

EP - 109

JO - Acta Physica Academiae Scientiarum Hungaricae

JF - Acta Physica Academiae Scientiarum Hungaricae

SN - 0001-6705

IS - 2

ER -