OBJECT: 3D cephalometry is often the only way to set up accurate diagnosis and treatment plan in the field of reconstructive surgery. In these cases complement exposures are needed beyond common cephalograms with higher accuracy than conventional Cone-Beam CT. Consequently the aim of our study was to perform a complex 3D cephalometry. As the first step of this approach, was the 3D adaptation of DiPaolo's Quadrilateral technique, and to determine norms of references in lower face by means of CBCT.

METHOD: Thirty non-orthodontic CBCT scans were selected for the digitalization. The most important inclusion criteria was Class I occlusion. Locations of 55 landmarks were signed three times by three observers by means of Cranio Viewer software.

RESULTS: However Quadrilateral analysis contains only millimetric values we also integrate angles in the 3D version to determine the width of maxilla and mandible. In the 2D examination--where landmarks were projected to the middle plane. The SDs of the lengths were between 2,66 mm and 5,20 mm. The ratios of normodivergent lower face were significant different from the one by DiPaolo. In 3D adaptation there were no significant differences between the measurements of the two sides (p ≥ 0.05). We found mostly strong and significant correlations between each anatomical structure except of angles.

CONCLUSION: Creation of 3D Quadrilateral cephalometry by means of strong correlation and norms of Class I occlusion provide a practical, reliable method to measure also the transversal asymmetry of lower face which is necessary part of 3D cephalometry.

Original languageHungarian
Pages (from-to)39-44
Number of pages6
JournalFogorvosi szemle
Volume109
Issue number2
Publication statusPublished - Jun 1 2016

Fingerprint

Cephalometry
Cone-Beam Computed Tomography
Reconstructive Surgical Procedures
Maxilla
Mandible
Software

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Dobai, A., Vizkelety, T., Markella, Z., Rosta, A., Kucserá, Á., & Barabás, J. (2016). Az alsó archarmad Di Paolo-féle vizsgálata Cone-Beam CT adatállományon. Fogorvosi szemle, 109(2), 39-44.

Az alsó archarmad Di Paolo-féle vizsgálata Cone-Beam CT adatállományon. / Dobai, Adrienn; Vizkelety, Tamás; Markella, Zsolt; Rosta, Adrienne; Kucserá, Ágnes; Barabás, J.

In: Fogorvosi szemle, Vol. 109, No. 2, 01.06.2016, p. 39-44.

Research output: Contribution to journalArticle

Dobai, A, Vizkelety, T, Markella, Z, Rosta, A, Kucserá, Á & Barabás, J 2016, 'Az alsó archarmad Di Paolo-féle vizsgálata Cone-Beam CT adatállományon', Fogorvosi szemle, vol. 109, no. 2, pp. 39-44.
Dobai A, Vizkelety T, Markella Z, Rosta A, Kucserá Á, Barabás J. Az alsó archarmad Di Paolo-féle vizsgálata Cone-Beam CT adatállományon. Fogorvosi szemle. 2016 Jun 1;109(2):39-44.
Dobai, Adrienn ; Vizkelety, Tamás ; Markella, Zsolt ; Rosta, Adrienne ; Kucserá, Ágnes ; Barabás, J. / Az alsó archarmad Di Paolo-féle vizsgálata Cone-Beam CT adatállományon. In: Fogorvosi szemle. 2016 ; Vol. 109, No. 2. pp. 39-44.
@article{1156213c30684529aacda9a8038570a3,
title = "Az als{\'o} archarmad Di Paolo-f{\'e}le vizsg{\'a}lata Cone-Beam CT adat{\'a}llom{\'a}nyon",
abstract = "OBJECT: 3D cephalometry is often the only way to set up accurate diagnosis and treatment plan in the field of reconstructive surgery. In these cases complement exposures are needed beyond common cephalograms with higher accuracy than conventional Cone-Beam CT. Consequently the aim of our study was to perform a complex 3D cephalometry. As the first step of this approach, was the 3D adaptation of DiPaolo's Quadrilateral technique, and to determine norms of references in lower face by means of CBCT.METHOD: Thirty non-orthodontic CBCT scans were selected for the digitalization. The most important inclusion criteria was Class I occlusion. Locations of 55 landmarks were signed three times by three observers by means of Cranio Viewer software.RESULTS: However Quadrilateral analysis contains only millimetric values we also integrate angles in the 3D version to determine the width of maxilla and mandible. In the 2D examination--where landmarks were projected to the middle plane. The SDs of the lengths were between 2,66 mm and 5,20 mm. The ratios of normodivergent lower face were significant different from the one by DiPaolo. In 3D adaptation there were no significant differences between the measurements of the two sides (p ≥ 0.05). We found mostly strong and significant correlations between each anatomical structure except of angles.CONCLUSION: Creation of 3D Quadrilateral cephalometry by means of strong correlation and norms of Class I occlusion provide a practical, reliable method to measure also the transversal asymmetry of lower face which is necessary part of 3D cephalometry.",
author = "Adrienn Dobai and Tam{\'a}s Vizkelety and Zsolt Markella and Adrienne Rosta and {\'A}gnes Kucser{\'a} and J. Barab{\'a}s",
year = "2016",
month = "6",
day = "1",
language = "Hungarian",
volume = "109",
pages = "39--44",
journal = "Fogorvosi szemle",
issn = "0015-5314",
publisher = "Ifjusagi Lapkiado Vallalat",
number = "2",

}

TY - JOUR

T1 - Az alsó archarmad Di Paolo-féle vizsgálata Cone-Beam CT adatállományon

AU - Dobai, Adrienn

AU - Vizkelety, Tamás

AU - Markella, Zsolt

AU - Rosta, Adrienne

AU - Kucserá, Ágnes

AU - Barabás, J.

PY - 2016/6/1

Y1 - 2016/6/1

N2 - OBJECT: 3D cephalometry is often the only way to set up accurate diagnosis and treatment plan in the field of reconstructive surgery. In these cases complement exposures are needed beyond common cephalograms with higher accuracy than conventional Cone-Beam CT. Consequently the aim of our study was to perform a complex 3D cephalometry. As the first step of this approach, was the 3D adaptation of DiPaolo's Quadrilateral technique, and to determine norms of references in lower face by means of CBCT.METHOD: Thirty non-orthodontic CBCT scans were selected for the digitalization. The most important inclusion criteria was Class I occlusion. Locations of 55 landmarks were signed three times by three observers by means of Cranio Viewer software.RESULTS: However Quadrilateral analysis contains only millimetric values we also integrate angles in the 3D version to determine the width of maxilla and mandible. In the 2D examination--where landmarks were projected to the middle plane. The SDs of the lengths were between 2,66 mm and 5,20 mm. The ratios of normodivergent lower face were significant different from the one by DiPaolo. In 3D adaptation there were no significant differences between the measurements of the two sides (p ≥ 0.05). We found mostly strong and significant correlations between each anatomical structure except of angles.CONCLUSION: Creation of 3D Quadrilateral cephalometry by means of strong correlation and norms of Class I occlusion provide a practical, reliable method to measure also the transversal asymmetry of lower face which is necessary part of 3D cephalometry.

AB - OBJECT: 3D cephalometry is often the only way to set up accurate diagnosis and treatment plan in the field of reconstructive surgery. In these cases complement exposures are needed beyond common cephalograms with higher accuracy than conventional Cone-Beam CT. Consequently the aim of our study was to perform a complex 3D cephalometry. As the first step of this approach, was the 3D adaptation of DiPaolo's Quadrilateral technique, and to determine norms of references in lower face by means of CBCT.METHOD: Thirty non-orthodontic CBCT scans were selected for the digitalization. The most important inclusion criteria was Class I occlusion. Locations of 55 landmarks were signed three times by three observers by means of Cranio Viewer software.RESULTS: However Quadrilateral analysis contains only millimetric values we also integrate angles in the 3D version to determine the width of maxilla and mandible. In the 2D examination--where landmarks were projected to the middle plane. The SDs of the lengths were between 2,66 mm and 5,20 mm. The ratios of normodivergent lower face were significant different from the one by DiPaolo. In 3D adaptation there were no significant differences between the measurements of the two sides (p ≥ 0.05). We found mostly strong and significant correlations between each anatomical structure except of angles.CONCLUSION: Creation of 3D Quadrilateral cephalometry by means of strong correlation and norms of Class I occlusion provide a practical, reliable method to measure also the transversal asymmetry of lower face which is necessary part of 3D cephalometry.

UR - http://www.scopus.com/inward/record.url?scp=84987621973&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84987621973&partnerID=8YFLogxK

M3 - Article

VL - 109

SP - 39

EP - 44

JO - Fogorvosi szemle

JF - Fogorvosi szemle

SN - 0015-5314

IS - 2

ER -