An automatic water sampling unit was developed to monitor the radioactive emission (radiocarbon and other corrosion and fission products) from nuclear facilities into the groundwater. Automatic sampling is based on the principal of ion exchange using built-in resin columns in the submerging samplers. In this way, even the short-term emissions can be detected. According to our experiments, the 14C activity concentrations and the δ13C values of the samples made by the ion exchange method are systematically underestimated compared to the real values. The carbonate adsorption feature of the sampling unit was studied under laboratory and field conditions. For this purpose, a test method was developed. The observed sampling efficiencies and additionally some carbon contamination for the sampling method itself have to be taken into consideration when we estimate the amount of 14C contamination introduced into the groundwater from a nuclear facility. Therefore, a correction factor should be made for the 14C anion exchange sampling. With the help of this correction, the results converge to the expected value.

Original languageEnglish
Pages (from-to)1141-1149
Number of pages9
JournalRadiocarbon
Volume52
Issue number3
Publication statusPublished - Aug 2010

Fingerprint

groundwater
sampling
ion exchange
sampler
measuring
Radiocarbon
Ground Water
Sampling
corrosion
resin
adsorption
carbonate
carbon
method
experiment
water
nuclear facility
contamination
Contamination

ASJC Scopus subject areas

  • Earth and Planetary Sciences(all)

Cite this

Janovics, R., Molnár, M., Futó, I., Rinyu, L., Svingor, É., Veres, M., ... Barnabás, I. (2010). Development of an automatic sampling unit for measuring radiocarbon content of groundwater. Radiocarbon, 52(3), 1141-1149.

Development of an automatic sampling unit for measuring radiocarbon content of groundwater. / Janovics, R.; Molnár, M.; Futó, I.; Rinyu, L.; Svingor, É; Veres, M.; Somogyi, I.; Barnabás, I.

In: Radiocarbon, Vol. 52, No. 3, 08.2010, p. 1141-1149.

Research output: Contribution to journalArticle

Janovics, R, Molnár, M, Futó, I, Rinyu, L, Svingor, É, Veres, M, Somogyi, I & Barnabás, I 2010, 'Development of an automatic sampling unit for measuring radiocarbon content of groundwater', Radiocarbon, vol. 52, no. 3, pp. 1141-1149.
Janovics R, Molnár M, Futó I, Rinyu L, Svingor É, Veres M et al. Development of an automatic sampling unit for measuring radiocarbon content of groundwater. Radiocarbon. 2010 Aug;52(3):1141-1149.
Janovics, R. ; Molnár, M. ; Futó, I. ; Rinyu, L. ; Svingor, É ; Veres, M. ; Somogyi, I. ; Barnabás, I. / Development of an automatic sampling unit for measuring radiocarbon content of groundwater. In: Radiocarbon. 2010 ; Vol. 52, No. 3. pp. 1141-1149.
@article{462443eb2ae14eee8f04625b6648a845,
title = "Development of an automatic sampling unit for measuring radiocarbon content of groundwater",
abstract = "An automatic water sampling unit was developed to monitor the radioactive emission (radiocarbon and other corrosion and fission products) from nuclear facilities into the groundwater. Automatic sampling is based on the principal of ion exchange using built-in resin columns in the submerging samplers. In this way, even the short-term emissions can be detected. According to our experiments, the 14C activity concentrations and the δ13C values of the samples made by the ion exchange method are systematically underestimated compared to the real values. The carbonate adsorption feature of the sampling unit was studied under laboratory and field conditions. For this purpose, a test method was developed. The observed sampling efficiencies and additionally some carbon contamination for the sampling method itself have to be taken into consideration when we estimate the amount of 14C contamination introduced into the groundwater from a nuclear facility. Therefore, a correction factor should be made for the 14C anion exchange sampling. With the help of this correction, the results converge to the expected value.",
author = "R. Janovics and M. Moln{\'a}r and I. Fut{\'o} and L. Rinyu and {\'E} Svingor and M. Veres and I. Somogyi and I. Barnab{\'a}s",
year = "2010",
month = "8",
language = "English",
volume = "52",
pages = "1141--1149",
journal = "Radiocarbon",
issn = "0033-8222",
publisher = "University of Arizona",
number = "3",

}

TY - JOUR

T1 - Development of an automatic sampling unit for measuring radiocarbon content of groundwater

AU - Janovics, R.

AU - Molnár, M.

AU - Futó, I.

AU - Rinyu, L.

AU - Svingor, É

AU - Veres, M.

AU - Somogyi, I.

AU - Barnabás, I.

PY - 2010/8

Y1 - 2010/8

N2 - An automatic water sampling unit was developed to monitor the radioactive emission (radiocarbon and other corrosion and fission products) from nuclear facilities into the groundwater. Automatic sampling is based on the principal of ion exchange using built-in resin columns in the submerging samplers. In this way, even the short-term emissions can be detected. According to our experiments, the 14C activity concentrations and the δ13C values of the samples made by the ion exchange method are systematically underestimated compared to the real values. The carbonate adsorption feature of the sampling unit was studied under laboratory and field conditions. For this purpose, a test method was developed. The observed sampling efficiencies and additionally some carbon contamination for the sampling method itself have to be taken into consideration when we estimate the amount of 14C contamination introduced into the groundwater from a nuclear facility. Therefore, a correction factor should be made for the 14C anion exchange sampling. With the help of this correction, the results converge to the expected value.

AB - An automatic water sampling unit was developed to monitor the radioactive emission (radiocarbon and other corrosion and fission products) from nuclear facilities into the groundwater. Automatic sampling is based on the principal of ion exchange using built-in resin columns in the submerging samplers. In this way, even the short-term emissions can be detected. According to our experiments, the 14C activity concentrations and the δ13C values of the samples made by the ion exchange method are systematically underestimated compared to the real values. The carbonate adsorption feature of the sampling unit was studied under laboratory and field conditions. For this purpose, a test method was developed. The observed sampling efficiencies and additionally some carbon contamination for the sampling method itself have to be taken into consideration when we estimate the amount of 14C contamination introduced into the groundwater from a nuclear facility. Therefore, a correction factor should be made for the 14C anion exchange sampling. With the help of this correction, the results converge to the expected value.

UR - http://www.scopus.com/inward/record.url?scp=78049267251&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=78049267251&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:78049267251

VL - 52

SP - 1141

EP - 1149

JO - Radiocarbon

JF - Radiocarbon

SN - 0033-8222

IS - 3

ER -