Determination of track parameters by diffraction method using laser light

M. Várnagy, J. Szabó, S. Juhász, J. Csikai

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Measurements were performed for determining the diameter of tracks by the Fraunhofer-diffraction method. A ≈1 mW He gas laser as a light source as well as cellulose acetate track detectors irradiated with alpha particles at different energies were used. The diameter of tracks determined by the diffraction method as well as those measured by microscope are in good agreement with each other.

Original languageEnglish
Pages (from-to)301-305
Number of pages5
JournalNuclear Instruments and Methods
Volume106
Issue number2
DOIs
Publication statusPublished - Jan 15 1973

Fingerprint

Lasers
Alpha Particles
Light
Gas Lasers
acetylcellulose

Cite this

Determination of track parameters by diffraction method using laser light. / Várnagy, M.; Szabó, J.; Juhász, S.; Csikai, J.

In: Nuclear Instruments and Methods, Vol. 106, No. 2, 15.01.1973, p. 301-305.

Research output: Contribution to journalArticle

Várnagy, M. ; Szabó, J. ; Juhász, S. ; Csikai, J. / Determination of track parameters by diffraction method using laser light. In: Nuclear Instruments and Methods. 1973 ; Vol. 106, No. 2. pp. 301-305.
@article{5d2308427adf41c3859dd97028e36166,
title = "Determination of track parameters by diffraction method using laser light",
abstract = "Measurements were performed for determining the diameter of tracks by the Fraunhofer-diffraction method. A ≈1 mW He gas laser as a light source as well as cellulose acetate track detectors irradiated with alpha particles at different energies were used. The diameter of tracks determined by the diffraction method as well as those measured by microscope are in good agreement with each other.",
author = "M. V{\'a}rnagy and J. Szab{\'o} and S. Juh{\'a}sz and J. Csikai",
year = "1973",
month = "1",
day = "15",
doi = "10.1016/0029-554X(73)90355-8",
language = "English",
volume = "106",
pages = "301--305",
journal = "Nuclear Instruments and Methods",
issn = "0029-554X",
publisher = "Elsevier BV",
number = "2",

}

TY - JOUR

T1 - Determination of track parameters by diffraction method using laser light

AU - Várnagy, M.

AU - Szabó, J.

AU - Juhász, S.

AU - Csikai, J.

PY - 1973/1/15

Y1 - 1973/1/15

N2 - Measurements were performed for determining the diameter of tracks by the Fraunhofer-diffraction method. A ≈1 mW He gas laser as a light source as well as cellulose acetate track detectors irradiated with alpha particles at different energies were used. The diameter of tracks determined by the diffraction method as well as those measured by microscope are in good agreement with each other.

AB - Measurements were performed for determining the diameter of tracks by the Fraunhofer-diffraction method. A ≈1 mW He gas laser as a light source as well as cellulose acetate track detectors irradiated with alpha particles at different energies were used. The diameter of tracks determined by the diffraction method as well as those measured by microscope are in good agreement with each other.

UR - http://www.scopus.com/inward/record.url?scp=49549170049&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=49549170049&partnerID=8YFLogxK

U2 - 10.1016/0029-554X(73)90355-8

DO - 10.1016/0029-554X(73)90355-8

M3 - Article

AN - SCOPUS:49549170049

VL - 106

SP - 301

EP - 305

JO - Nuclear Instruments and Methods

JF - Nuclear Instruments and Methods

SN - 0029-554X

IS - 2

ER -