Determination of Ta impurities in Nb samples by X-rays in neutron activation analysis

S. Szegedi, G. Kanalics, M. Váradi, G. Zilizi

Research output: Contribution to journalArticle

Abstract

Ta impurities in Nb samples have been determined by X-rays in 14 MeV neutron activation analysis. For X-ray detection, (HP) Ge detector with Be-window is used. The sensitivity of the determination has been found to be about 30 μg (in Nb).

Original languageEnglish
Pages (from-to)343-350
Number of pages8
JournalJournal of Radioanalytical and Nuclear Chemistry
Volume155
Issue number5
DOIs
Publication statusPublished - Nov 1991

Fingerprint

Neutron Activation Analysis
Neutron activation analysis
X-Rays
Impurities
X rays
Detectors

ASJC Scopus subject areas

  • Nuclear Energy and Engineering
  • Inorganic Chemistry
  • Analytical Chemistry

Cite this

Determination of Ta impurities in Nb samples by X-rays in neutron activation analysis. / Szegedi, S.; Kanalics, G.; Váradi, M.; Zilizi, G.

In: Journal of Radioanalytical and Nuclear Chemistry, Vol. 155, No. 5, 11.1991, p. 343-350.

Research output: Contribution to journalArticle

@article{fb8ccf2afd1a4239a5429e97fd5786bf,
title = "Determination of Ta impurities in Nb samples by X-rays in neutron activation analysis",
abstract = "Ta impurities in Nb samples have been determined by X-rays in 14 MeV neutron activation analysis. For X-ray detection, (HP) Ge detector with Be-window is used. The sensitivity of the determination has been found to be about 30 μg (in Nb).",
author = "S. Szegedi and G. Kanalics and M. V{\'a}radi and G. Zilizi",
year = "1991",
month = "11",
doi = "10.1007/BF02163881",
language = "English",
volume = "155",
pages = "343--350",
journal = "Journal of Radioanalytical and Nuclear Chemistry",
issn = "0022-4081",
publisher = "Elsevier BV",
number = "5",

}

TY - JOUR

T1 - Determination of Ta impurities in Nb samples by X-rays in neutron activation analysis

AU - Szegedi, S.

AU - Kanalics, G.

AU - Váradi, M.

AU - Zilizi, G.

PY - 1991/11

Y1 - 1991/11

N2 - Ta impurities in Nb samples have been determined by X-rays in 14 MeV neutron activation analysis. For X-ray detection, (HP) Ge detector with Be-window is used. The sensitivity of the determination has been found to be about 30 μg (in Nb).

AB - Ta impurities in Nb samples have been determined by X-rays in 14 MeV neutron activation analysis. For X-ray detection, (HP) Ge detector with Be-window is used. The sensitivity of the determination has been found to be about 30 μg (in Nb).

UR - http://www.scopus.com/inward/record.url?scp=0026052761&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026052761&partnerID=8YFLogxK

U2 - 10.1007/BF02163881

DO - 10.1007/BF02163881

M3 - Article

AN - SCOPUS:0026052761

VL - 155

SP - 343

EP - 350

JO - Journal of Radioanalytical and Nuclear Chemistry

JF - Journal of Radioanalytical and Nuclear Chemistry

SN - 0022-4081

IS - 5

ER -