Determination of aplovincaminic acid in biological samples by high-performance liquid chromatography

Maria Kozma, Piroska Pudleiner, L. Vereczkey

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

A method is described for measuring the concentrations of apovincaminic acid and vincaminic acid (internal standard) in blood plasma and urine by high-performance liquid chromatography using ion pair extraction. The main metabolite of vinpocetine, apovincaminic acid, and vincaminic acid were extracted form 1 ml of plasma and urine into chloroform as an ion pair using tetrabutylammonium hydroxide as counter ion. Analysis was carried out on a reversed-phase column of RP-8 with acetonitrile-0.0075 M phosphate buffer (28:72) at pH 3.5 as mobile phase. The eluted derivatives were detected by UV absorption at 254 nm. The sensitivity of the method is 20 ng/ml for AVA in plasma and urine samples. The relative recovery of these compounds added to plasma was about 50%.

Original languageEnglish
Pages (from-to)177-182
Number of pages6
JournalJournal of Chromatography A
Volume241
Issue number1
DOIs
Publication statusPublished - May 28 1982

Fingerprint

High performance liquid chromatography
High Pressure Liquid Chromatography
Plasmas
Acids
vinpocetine
Urine
Ions
Radiation counters
Chloroform
Metabolites
Buffers
Blood
Phosphates
Derivatives
Recovery
apovincaminic acid

ASJC Scopus subject areas

  • Analytical Chemistry
  • Clinical Biochemistry
  • Molecular Medicine

Cite this

Determination of aplovincaminic acid in biological samples by high-performance liquid chromatography. / Kozma, Maria; Pudleiner, Piroska; Vereczkey, L.

In: Journal of Chromatography A, Vol. 241, No. 1, 28.05.1982, p. 177-182.

Research output: Contribution to journalArticle

@article{be759ce1aab14f7190207db6a131d83f,
title = "Determination of aplovincaminic acid in biological samples by high-performance liquid chromatography",
abstract = "A method is described for measuring the concentrations of apovincaminic acid and vincaminic acid (internal standard) in blood plasma and urine by high-performance liquid chromatography using ion pair extraction. The main metabolite of vinpocetine, apovincaminic acid, and vincaminic acid were extracted form 1 ml of plasma and urine into chloroform as an ion pair using tetrabutylammonium hydroxide as counter ion. Analysis was carried out on a reversed-phase column of RP-8 with acetonitrile-0.0075 M phosphate buffer (28:72) at pH 3.5 as mobile phase. The eluted derivatives were detected by UV absorption at 254 nm. The sensitivity of the method is 20 ng/ml for AVA in plasma and urine samples. The relative recovery of these compounds added to plasma was about 50{\%}.",
author = "Maria Kozma and Piroska Pudleiner and L. Vereczkey",
year = "1982",
month = "5",
day = "28",
doi = "10.1016/S0021-9673(00)82402-4",
language = "English",
volume = "241",
pages = "177--182",
journal = "Journal of Chromatography",
issn = "0021-9673",
publisher = "Elsevier",
number = "1",

}

TY - JOUR

T1 - Determination of aplovincaminic acid in biological samples by high-performance liquid chromatography

AU - Kozma, Maria

AU - Pudleiner, Piroska

AU - Vereczkey, L.

PY - 1982/5/28

Y1 - 1982/5/28

N2 - A method is described for measuring the concentrations of apovincaminic acid and vincaminic acid (internal standard) in blood plasma and urine by high-performance liquid chromatography using ion pair extraction. The main metabolite of vinpocetine, apovincaminic acid, and vincaminic acid were extracted form 1 ml of plasma and urine into chloroform as an ion pair using tetrabutylammonium hydroxide as counter ion. Analysis was carried out on a reversed-phase column of RP-8 with acetonitrile-0.0075 M phosphate buffer (28:72) at pH 3.5 as mobile phase. The eluted derivatives were detected by UV absorption at 254 nm. The sensitivity of the method is 20 ng/ml for AVA in plasma and urine samples. The relative recovery of these compounds added to plasma was about 50%.

AB - A method is described for measuring the concentrations of apovincaminic acid and vincaminic acid (internal standard) in blood plasma and urine by high-performance liquid chromatography using ion pair extraction. The main metabolite of vinpocetine, apovincaminic acid, and vincaminic acid were extracted form 1 ml of plasma and urine into chloroform as an ion pair using tetrabutylammonium hydroxide as counter ion. Analysis was carried out on a reversed-phase column of RP-8 with acetonitrile-0.0075 M phosphate buffer (28:72) at pH 3.5 as mobile phase. The eluted derivatives were detected by UV absorption at 254 nm. The sensitivity of the method is 20 ng/ml for AVA in plasma and urine samples. The relative recovery of these compounds added to plasma was about 50%.

UR - http://www.scopus.com/inward/record.url?scp=0020360608&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0020360608&partnerID=8YFLogxK

U2 - 10.1016/S0021-9673(00)82402-4

DO - 10.1016/S0021-9673(00)82402-4

M3 - Article

C2 - 7107794

AN - SCOPUS:0020360608

VL - 241

SP - 177

EP - 182

JO - Journal of Chromatography

JF - Journal of Chromatography

SN - 0021-9673

IS - 1

ER -