Gazkromatograf-tomegspektrometer es PDP-11 tipusu szamitogep mikroprocesszor vezerelt illesztoegysegenek epitese es alkalmazasa

Translated title of the contribution: Design and use of the microprocessor controlled interface of a gas chromatograph - mass spectrometer and a computer, type PDP-11

A. Gömöry, Istvan Besenyei, Gabor Czira, Jozsef Tamas

Research output: Contribution to journalArticle

Abstract

The unit works on the principle of sampling and connects a magnetic mass spectrometer joined up with a gas chromatograph (GC-MS system) to a minicomputer, type PDP-11. Based on the (16 byte) microprocessor Motorola 68 000, it can be programmed flexibly and thus, can be used also for collecting automated data from special mass spectrometric and other measurements, beside the normal spectrum data. During measurement and data collecting, optional evaluation tasks can be carried out on a central computer in the operational system RSX 11M. According to experience, the interface unit proves to be quick enough for modern capillary GC-MS measurements with a significant improvement of sensitivity.

Original languageHungarian
Pages (from-to)216-220
Number of pages5
JournalMeres es automatika
Volume37
Issue number4
Publication statusPublished - Jul 1989

Fingerprint

Mass spectrometers
Microprocessor chips
Gases
Minicomputers
Sampling

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Gazkromatograf-tomegspektrometer es PDP-11 tipusu szamitogep mikroprocesszor vezerelt illesztoegysegenek epitese es alkalmazasa. / Gömöry, A.; Besenyei, Istvan; Czira, Gabor; Tamas, Jozsef.

In: Meres es automatika, Vol. 37, No. 4, 07.1989, p. 216-220.

Research output: Contribution to journalArticle

@article{edaf1ed4b3cd4afeb4448e21eb60bf2a,
title = "Gazkromatograf-tomegspektrometer es PDP-11 tipusu szamitogep mikroprocesszor vezerelt illesztoegysegenek epitese es alkalmazasa",
abstract = "The unit works on the principle of sampling and connects a magnetic mass spectrometer joined up with a gas chromatograph (GC-MS system) to a minicomputer, type PDP-11. Based on the (16 byte) microprocessor Motorola 68 000, it can be programmed flexibly and thus, can be used also for collecting automated data from special mass spectrometric and other measurements, beside the normal spectrum data. During measurement and data collecting, optional evaluation tasks can be carried out on a central computer in the operational system RSX 11M. According to experience, the interface unit proves to be quick enough for modern capillary GC-MS measurements with a significant improvement of sensitivity.",
author = "A. G{\"o}m{\"o}ry and Istvan Besenyei and Gabor Czira and Jozsef Tamas",
year = "1989",
month = "7",
language = "Hungarian",
volume = "37",
pages = "216--220",
journal = "Meres es automatika",
issn = "0025-9993",
number = "4",

}

TY - JOUR

T1 - Gazkromatograf-tomegspektrometer es PDP-11 tipusu szamitogep mikroprocesszor vezerelt illesztoegysegenek epitese es alkalmazasa

AU - Gömöry, A.

AU - Besenyei, Istvan

AU - Czira, Gabor

AU - Tamas, Jozsef

PY - 1989/7

Y1 - 1989/7

N2 - The unit works on the principle of sampling and connects a magnetic mass spectrometer joined up with a gas chromatograph (GC-MS system) to a minicomputer, type PDP-11. Based on the (16 byte) microprocessor Motorola 68 000, it can be programmed flexibly and thus, can be used also for collecting automated data from special mass spectrometric and other measurements, beside the normal spectrum data. During measurement and data collecting, optional evaluation tasks can be carried out on a central computer in the operational system RSX 11M. According to experience, the interface unit proves to be quick enough for modern capillary GC-MS measurements with a significant improvement of sensitivity.

AB - The unit works on the principle of sampling and connects a magnetic mass spectrometer joined up with a gas chromatograph (GC-MS system) to a minicomputer, type PDP-11. Based on the (16 byte) microprocessor Motorola 68 000, it can be programmed flexibly and thus, can be used also for collecting automated data from special mass spectrometric and other measurements, beside the normal spectrum data. During measurement and data collecting, optional evaluation tasks can be carried out on a central computer in the operational system RSX 11M. According to experience, the interface unit proves to be quick enough for modern capillary GC-MS measurements with a significant improvement of sensitivity.

UR - http://www.scopus.com/inward/record.url?scp=0024704258&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024704258&partnerID=8YFLogxK

M3 - Article

VL - 37

SP - 216

EP - 220

JO - Meres es automatika

JF - Meres es automatika

SN - 0025-9993

IS - 4