The drop in blood pressure coinciding with the atrioventricular dyssynchrony plays an important role in the genesis of pacemaker syndrome. The diagnosis is often based on continuous blood pressure recording. Formerly the continuous blood pressure monitoring could only be performed by invasive methods. The authors demonstrate the feasibility of a new non invasive continuous blood pressure recorder, the Finapres 2300, by presenting illustrative case reports. The authors recommend more widespread use of non invasive haemodynamic monitoring for the diagnosis of pacemaker syndrome.

Original languageHungarian
Pages (from-to)1255-1258
Number of pages4
JournalOrvosi Hetilap
Volume135
Issue number23
Publication statusPublished - Jun 5 1994

Fingerprint

Blood Pressure
Hemodynamics

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Folyamatos, noninvazív vérnyomásmérés a pacemaker szindróma diagnózisában. / Szabados, S.; Kardos, A.; Simon, J.; Gingl, Z.; Hegedüs, Z.; Rudas, L.

In: Orvosi Hetilap, Vol. 135, No. 23, 05.06.1994, p. 1255-1258.

Research output: Contribution to journalArticle

@article{3cb4649ba763472ea987eabda8606ffe,
title = "Folyamatos, noninvaz{\'i}v v{\'e}rnyom{\'a}sm{\'e}r{\'e}s a pacemaker szindr{\'o}ma diagn{\'o}zis{\'a}ban.",
abstract = "The drop in blood pressure coinciding with the atrioventricular dyssynchrony plays an important role in the genesis of pacemaker syndrome. The diagnosis is often based on continuous blood pressure recording. Formerly the continuous blood pressure monitoring could only be performed by invasive methods. The authors demonstrate the feasibility of a new non invasive continuous blood pressure recorder, the Finapres 2300, by presenting illustrative case reports. The authors recommend more widespread use of non invasive haemodynamic monitoring for the diagnosis of pacemaker syndrome.",
author = "S. Szabados and A. Kardos and J. Simon and Z. Gingl and Z. Heged{\"u}s and L. Rudas",
year = "1994",
month = "6",
day = "5",
language = "Hungarian",
volume = "135",
pages = "1255--1258",
journal = "Orvosi Hetilap",
issn = "0030-6002",
publisher = "Akademiai Kiado",
number = "23",

}

TY - JOUR

T1 - Folyamatos, noninvazív vérnyomásmérés a pacemaker szindróma diagnózisában.

AU - Szabados, S.

AU - Kardos, A.

AU - Simon, J.

AU - Gingl, Z.

AU - Hegedüs, Z.

AU - Rudas, L.

PY - 1994/6/5

Y1 - 1994/6/5

N2 - The drop in blood pressure coinciding with the atrioventricular dyssynchrony plays an important role in the genesis of pacemaker syndrome. The diagnosis is often based on continuous blood pressure recording. Formerly the continuous blood pressure monitoring could only be performed by invasive methods. The authors demonstrate the feasibility of a new non invasive continuous blood pressure recorder, the Finapres 2300, by presenting illustrative case reports. The authors recommend more widespread use of non invasive haemodynamic monitoring for the diagnosis of pacemaker syndrome.

AB - The drop in blood pressure coinciding with the atrioventricular dyssynchrony plays an important role in the genesis of pacemaker syndrome. The diagnosis is often based on continuous blood pressure recording. Formerly the continuous blood pressure monitoring could only be performed by invasive methods. The authors demonstrate the feasibility of a new non invasive continuous blood pressure recorder, the Finapres 2300, by presenting illustrative case reports. The authors recommend more widespread use of non invasive haemodynamic monitoring for the diagnosis of pacemaker syndrome.

UR - http://www.scopus.com/inward/record.url?scp=17644431413&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=17644431413&partnerID=8YFLogxK

M3 - Article

VL - 135

SP - 1255

EP - 1258

JO - Orvosi Hetilap

JF - Orvosi Hetilap

SN - 0030-6002

IS - 23

ER -