A folyamatos glukózszenzor (CGMS) értékes eszköz a gyermek- és serdülokori diabetes mellitus gondozásában.

Translated title of the contribution: Continuous glucose monitoring system, as a valuable tool in the care of children and adolescents with diabetes mellitus

Péter Tóth-Heyn, A. Körner, L. Madácsy

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

INTRODUCTION: Good metabolic control of diabetic patients is mainly based on the results of self measured blood glucose levels. Important excursions of blood glucose may, however, be hidden in the usual case of 4-5 daily determinations. The aim of this paper was to give detailed information about this new diagnostic tool and to report the first Hungarian pediatric experiences with continuous glucose monitoring. METHOD: Continuous glucose monitoring system (Mini-Med) is able to monitor the changes of tissue glucose levels for up to 72 hours by measuring glucose concentration via a s.c. canula every 5 minutes. In its present form the results of continuous glucose monitoring cannot be observed real time by the patient, it provides useful information retrospectively mainly for the doctor. RESULTS: The sensor detected unexpectedly high fluctuation of glucose levels in several patients. It was possible to distinguish between nighttime hypoglycaemia (Somogyi-effect) or dawn phenomenon-induced morning hyperglycaemiae by the use of continuous glucose monitoring. Fever may influence peripheral circulation representing a limitation in the use (or evaluation) of continuous tissue glucose monitoring. The authors found good correlation between continuous glucose monitoring and self blood glucose monitoring results. The best correlation was observed in the low blood glucose range. CONCLUSIONS: The continuous glucose monitoring results provide useful information for the diabetologist in order to modify insulin treatment. Continuous glucose monitoring-based changes in insulin treatment are reported to result in better long term metabolic control. Continuous glucose monitoring in the near future will obviously play a primary role in insulin pump therapy where it will provide glucose result for the pump.

Original languageHungarian
Pages (from-to)1265-1270
Number of pages6
JournalOrvosi Hetilap
Volume145
Issue number24
Publication statusPublished - Jun 13 2004

Fingerprint

Child Care
Diabetes Mellitus
Glucose
Blood Glucose
Insulin
Blood Glucose Self-Monitoring
Hypoglycemia
Fever
Therapeutics
Pediatrics

ASJC Scopus subject areas

  • Medicine(all)

Cite this

A folyamatos glukózszenzor (CGMS) értékes eszköz a gyermek- és serdülokori diabetes mellitus gondozásában. / Tóth-Heyn, Péter; Körner, A.; Madácsy, L.

In: Orvosi Hetilap, Vol. 145, No. 24, 13.06.2004, p. 1265-1270.

Research output: Contribution to journalArticle

@article{82b5b21fd80e4d1a82d21fafe18229f8,
title = "A folyamatos gluk{\'o}zszenzor (CGMS) {\'e}rt{\'e}kes eszk{\"o}z a gyermek- {\'e}s serd{\"u}lokori diabetes mellitus gondoz{\'a}s{\'a}ban.",
abstract = "INTRODUCTION: Good metabolic control of diabetic patients is mainly based on the results of self measured blood glucose levels. Important excursions of blood glucose may, however, be hidden in the usual case of 4-5 daily determinations. The aim of this paper was to give detailed information about this new diagnostic tool and to report the first Hungarian pediatric experiences with continuous glucose monitoring. METHOD: Continuous glucose monitoring system (Mini-Med) is able to monitor the changes of tissue glucose levels for up to 72 hours by measuring glucose concentration via a s.c. canula every 5 minutes. In its present form the results of continuous glucose monitoring cannot be observed real time by the patient, it provides useful information retrospectively mainly for the doctor. RESULTS: The sensor detected unexpectedly high fluctuation of glucose levels in several patients. It was possible to distinguish between nighttime hypoglycaemia (Somogyi-effect) or dawn phenomenon-induced morning hyperglycaemiae by the use of continuous glucose monitoring. Fever may influence peripheral circulation representing a limitation in the use (or evaluation) of continuous tissue glucose monitoring. The authors found good correlation between continuous glucose monitoring and self blood glucose monitoring results. The best correlation was observed in the low blood glucose range. CONCLUSIONS: The continuous glucose monitoring results provide useful information for the diabetologist in order to modify insulin treatment. Continuous glucose monitoring-based changes in insulin treatment are reported to result in better long term metabolic control. Continuous glucose monitoring in the near future will obviously play a primary role in insulin pump therapy where it will provide glucose result for the pump.",
author = "P{\'e}ter T{\'o}th-Heyn and A. K{\"o}rner and L. Mad{\'a}csy",
year = "2004",
month = "6",
day = "13",
language = "Hungarian",
volume = "145",
pages = "1265--1270",
journal = "Orvosi Hetilap",
issn = "0030-6002",
publisher = "Akademiai Kiado",
number = "24",

}

TY - JOUR

T1 - A folyamatos glukózszenzor (CGMS) értékes eszköz a gyermek- és serdülokori diabetes mellitus gondozásában.

AU - Tóth-Heyn, Péter

AU - Körner, A.

AU - Madácsy, L.

PY - 2004/6/13

Y1 - 2004/6/13

N2 - INTRODUCTION: Good metabolic control of diabetic patients is mainly based on the results of self measured blood glucose levels. Important excursions of blood glucose may, however, be hidden in the usual case of 4-5 daily determinations. The aim of this paper was to give detailed information about this new diagnostic tool and to report the first Hungarian pediatric experiences with continuous glucose monitoring. METHOD: Continuous glucose monitoring system (Mini-Med) is able to monitor the changes of tissue glucose levels for up to 72 hours by measuring glucose concentration via a s.c. canula every 5 minutes. In its present form the results of continuous glucose monitoring cannot be observed real time by the patient, it provides useful information retrospectively mainly for the doctor. RESULTS: The sensor detected unexpectedly high fluctuation of glucose levels in several patients. It was possible to distinguish between nighttime hypoglycaemia (Somogyi-effect) or dawn phenomenon-induced morning hyperglycaemiae by the use of continuous glucose monitoring. Fever may influence peripheral circulation representing a limitation in the use (or evaluation) of continuous tissue glucose monitoring. The authors found good correlation between continuous glucose monitoring and self blood glucose monitoring results. The best correlation was observed in the low blood glucose range. CONCLUSIONS: The continuous glucose monitoring results provide useful information for the diabetologist in order to modify insulin treatment. Continuous glucose monitoring-based changes in insulin treatment are reported to result in better long term metabolic control. Continuous glucose monitoring in the near future will obviously play a primary role in insulin pump therapy where it will provide glucose result for the pump.

AB - INTRODUCTION: Good metabolic control of diabetic patients is mainly based on the results of self measured blood glucose levels. Important excursions of blood glucose may, however, be hidden in the usual case of 4-5 daily determinations. The aim of this paper was to give detailed information about this new diagnostic tool and to report the first Hungarian pediatric experiences with continuous glucose monitoring. METHOD: Continuous glucose monitoring system (Mini-Med) is able to monitor the changes of tissue glucose levels for up to 72 hours by measuring glucose concentration via a s.c. canula every 5 minutes. In its present form the results of continuous glucose monitoring cannot be observed real time by the patient, it provides useful information retrospectively mainly for the doctor. RESULTS: The sensor detected unexpectedly high fluctuation of glucose levels in several patients. It was possible to distinguish between nighttime hypoglycaemia (Somogyi-effect) or dawn phenomenon-induced morning hyperglycaemiae by the use of continuous glucose monitoring. Fever may influence peripheral circulation representing a limitation in the use (or evaluation) of continuous tissue glucose monitoring. The authors found good correlation between continuous glucose monitoring and self blood glucose monitoring results. The best correlation was observed in the low blood glucose range. CONCLUSIONS: The continuous glucose monitoring results provide useful information for the diabetologist in order to modify insulin treatment. Continuous glucose monitoring-based changes in insulin treatment are reported to result in better long term metabolic control. Continuous glucose monitoring in the near future will obviously play a primary role in insulin pump therapy where it will provide glucose result for the pump.

UR - http://www.scopus.com/inward/record.url?scp=3943100028&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=3943100028&partnerID=8YFLogxK

M3 - Article

C2 - 15264753

AN - SCOPUS:3943100028

VL - 145

SP - 1265

EP - 1270

JO - Orvosi Hetilap

JF - Orvosi Hetilap

SN - 0030-6002

IS - 24

ER -