The identification of the aorta segment by applying the pulsatile blood pressure components measured in the ascending aorta and iliac artery in dogs is described. Approximate transfer functions containing four poles, two or four zeros and dead time were determined by three methods at several arterial mean pressure levels.

Original languageEnglish
Title of host publicationUnknown Host Publication Title
PublisherNorth-Holland Publ Co
Pages235-238
Number of pages4
Publication statusPublished - 1973

Fingerprint

Cardiovascular system
Blood pressure
Transfer functions
Poles

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Szucs, B., Monos, E., & Szutrely, J. (1973). COMPARISON OF IDENTIFICATION METHODS IN THE CARDIOVASCULAR SYSTEM. In Unknown Host Publication Title (pp. 235-238). North-Holland Publ Co.

COMPARISON OF IDENTIFICATION METHODS IN THE CARDIOVASCULAR SYSTEM. / Szucs, Bela; Monos, E.; Szutrely, Judit.

Unknown Host Publication Title. North-Holland Publ Co, 1973. p. 235-238.

Research output: Chapter in Book/Report/Conference proceedingChapter

Szucs, B, Monos, E & Szutrely, J 1973, COMPARISON OF IDENTIFICATION METHODS IN THE CARDIOVASCULAR SYSTEM. in Unknown Host Publication Title. North-Holland Publ Co, pp. 235-238.
Szucs B, Monos E, Szutrely J. COMPARISON OF IDENTIFICATION METHODS IN THE CARDIOVASCULAR SYSTEM. In Unknown Host Publication Title. North-Holland Publ Co. 1973. p. 235-238
Szucs, Bela ; Monos, E. ; Szutrely, Judit. / COMPARISON OF IDENTIFICATION METHODS IN THE CARDIOVASCULAR SYSTEM. Unknown Host Publication Title. North-Holland Publ Co, 1973. pp. 235-238
@inbook{dc2a70adf5614c789d82cb41faf81cc9,
title = "COMPARISON OF IDENTIFICATION METHODS IN THE CARDIOVASCULAR SYSTEM.",
abstract = "The identification of the aorta segment by applying the pulsatile blood pressure components measured in the ascending aorta and iliac artery in dogs is described. Approximate transfer functions containing four poles, two or four zeros and dead time were determined by three methods at several arterial mean pressure levels.",
author = "Bela Szucs and E. Monos and Judit Szutrely",
year = "1973",
language = "English",
pages = "235--238",
booktitle = "Unknown Host Publication Title",
publisher = "North-Holland Publ Co",

}

TY - CHAP

T1 - COMPARISON OF IDENTIFICATION METHODS IN THE CARDIOVASCULAR SYSTEM.

AU - Szucs, Bela

AU - Monos, E.

AU - Szutrely, Judit

PY - 1973

Y1 - 1973

N2 - The identification of the aorta segment by applying the pulsatile blood pressure components measured in the ascending aorta and iliac artery in dogs is described. Approximate transfer functions containing four poles, two or four zeros and dead time were determined by three methods at several arterial mean pressure levels.

AB - The identification of the aorta segment by applying the pulsatile blood pressure components measured in the ascending aorta and iliac artery in dogs is described. Approximate transfer functions containing four poles, two or four zeros and dead time were determined by three methods at several arterial mean pressure levels.

UR - http://www.scopus.com/inward/record.url?scp=0015775310&partnerID=8YFLogxK