Comparison of high-performance liquid chromatography and capillary electrophoresis in the analysis of somatostatin analogue peptides

M. Idei, I. Mezo, Zs Vadász, A. Horváth, I. Teplán, G. Kéri

Research output: Contribution to journalArticle

25 Citations (Scopus)

Abstract

HPLC and CE methods were developed for analysis of somatostatin analogue (S-analogue) peptides utilizing triethylammonium phosphate-organic solvent modifier solvents as the CE buffer and HPLC eluent. Acetonitrile, methanol, ethanol and 2-propanol were applied as organic modifiers. The applicability of HPLC and CE systems was evaluated and compared. Optimum conditions for the separation were determined for both methods. Retention (migration) time, elution order and selectivity can be influenced by modifying the composition of the eluent (buffer) with organic solvents not only in HPLC but also in CE. Although the HPLC system reacted to changes in the organic solvent concentration in a much more sensitive way than the CE system did (from the point of view of retention time), CE proved to be a more suitable method for separating the peptides investigated. Baseline separation could be achieved within 6-9 min by CE, a result which was impossible to achieve with HPLC working in the isocratic mode. In CE the effect of the alcohols on migration times proved to be opposite to that of acetonitrile. Whereas ACN decreased, the alcohols increased the migration times in a concentration-dependent way. The results suggest that CE can be applied very advantageously in peptide analysis. Its performance regarding selectivity, resolution, theoretical plate number, duration and cost is comparable or sometimes superior to that of HPLC.

Original languageEnglish
Pages (from-to)251-256
Number of pages6
JournalJournal of Chromatography A
Volume648
Issue number1
DOIs
Publication statusPublished - Oct 1 1993

Fingerprint

Capillary electrophoresis
Capillary Electrophoresis
High performance liquid chromatography
Somatostatin
Organic solvents
High Pressure Liquid Chromatography
Peptides
Buffers
Alcohols
2-Propanol
Methanol
Ethanol
Chemical analysis
Organophosphates
Costs
acetonitrile
Costs and Cost Analysis

ASJC Scopus subject areas

  • Analytical Chemistry
  • Clinical Biochemistry
  • Molecular Medicine

Cite this

Comparison of high-performance liquid chromatography and capillary electrophoresis in the analysis of somatostatin analogue peptides. / Idei, M.; Mezo, I.; Vadász, Zs; Horváth, A.; Teplán, I.; Kéri, G.

In: Journal of Chromatography A, Vol. 648, No. 1, 01.10.1993, p. 251-256.

Research output: Contribution to journalArticle

@article{6484a485129a4ace8ee3a3b87baaaa29,
title = "Comparison of high-performance liquid chromatography and capillary electrophoresis in the analysis of somatostatin analogue peptides",
abstract = "HPLC and CE methods were developed for analysis of somatostatin analogue (S-analogue) peptides utilizing triethylammonium phosphate-organic solvent modifier solvents as the CE buffer and HPLC eluent. Acetonitrile, methanol, ethanol and 2-propanol were applied as organic modifiers. The applicability of HPLC and CE systems was evaluated and compared. Optimum conditions for the separation were determined for both methods. Retention (migration) time, elution order and selectivity can be influenced by modifying the composition of the eluent (buffer) with organic solvents not only in HPLC but also in CE. Although the HPLC system reacted to changes in the organic solvent concentration in a much more sensitive way than the CE system did (from the point of view of retention time), CE proved to be a more suitable method for separating the peptides investigated. Baseline separation could be achieved within 6-9 min by CE, a result which was impossible to achieve with HPLC working in the isocratic mode. In CE the effect of the alcohols on migration times proved to be opposite to that of acetonitrile. Whereas ACN decreased, the alcohols increased the migration times in a concentration-dependent way. The results suggest that CE can be applied very advantageously in peptide analysis. Its performance regarding selectivity, resolution, theoretical plate number, duration and cost is comparable or sometimes superior to that of HPLC.",
author = "M. Idei and I. Mezo and Zs Vad{\'a}sz and A. Horv{\'a}th and I. Tepl{\'a}n and G. K{\'e}ri",
year = "1993",
month = "10",
day = "1",
doi = "10.1016/0021-9673(93)83308-F",
language = "English",
volume = "648",
pages = "251--256",
journal = "Journal of Chromatography",
issn = "0021-9673",
publisher = "Elsevier",
number = "1",

}

TY - JOUR

T1 - Comparison of high-performance liquid chromatography and capillary electrophoresis in the analysis of somatostatin analogue peptides

AU - Idei, M.

AU - Mezo, I.

AU - Vadász, Zs

AU - Horváth, A.

AU - Teplán, I.

AU - Kéri, G.

PY - 1993/10/1

Y1 - 1993/10/1

N2 - HPLC and CE methods were developed for analysis of somatostatin analogue (S-analogue) peptides utilizing triethylammonium phosphate-organic solvent modifier solvents as the CE buffer and HPLC eluent. Acetonitrile, methanol, ethanol and 2-propanol were applied as organic modifiers. The applicability of HPLC and CE systems was evaluated and compared. Optimum conditions for the separation were determined for both methods. Retention (migration) time, elution order and selectivity can be influenced by modifying the composition of the eluent (buffer) with organic solvents not only in HPLC but also in CE. Although the HPLC system reacted to changes in the organic solvent concentration in a much more sensitive way than the CE system did (from the point of view of retention time), CE proved to be a more suitable method for separating the peptides investigated. Baseline separation could be achieved within 6-9 min by CE, a result which was impossible to achieve with HPLC working in the isocratic mode. In CE the effect of the alcohols on migration times proved to be opposite to that of acetonitrile. Whereas ACN decreased, the alcohols increased the migration times in a concentration-dependent way. The results suggest that CE can be applied very advantageously in peptide analysis. Its performance regarding selectivity, resolution, theoretical plate number, duration and cost is comparable or sometimes superior to that of HPLC.

AB - HPLC and CE methods were developed for analysis of somatostatin analogue (S-analogue) peptides utilizing triethylammonium phosphate-organic solvent modifier solvents as the CE buffer and HPLC eluent. Acetonitrile, methanol, ethanol and 2-propanol were applied as organic modifiers. The applicability of HPLC and CE systems was evaluated and compared. Optimum conditions for the separation were determined for both methods. Retention (migration) time, elution order and selectivity can be influenced by modifying the composition of the eluent (buffer) with organic solvents not only in HPLC but also in CE. Although the HPLC system reacted to changes in the organic solvent concentration in a much more sensitive way than the CE system did (from the point of view of retention time), CE proved to be a more suitable method for separating the peptides investigated. Baseline separation could be achieved within 6-9 min by CE, a result which was impossible to achieve with HPLC working in the isocratic mode. In CE the effect of the alcohols on migration times proved to be opposite to that of acetonitrile. Whereas ACN decreased, the alcohols increased the migration times in a concentration-dependent way. The results suggest that CE can be applied very advantageously in peptide analysis. Its performance regarding selectivity, resolution, theoretical plate number, duration and cost is comparable or sometimes superior to that of HPLC.

UR - http://www.scopus.com/inward/record.url?scp=0027359511&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027359511&partnerID=8YFLogxK

U2 - 10.1016/0021-9673(93)83308-F

DO - 10.1016/0021-9673(93)83308-F

M3 - Article

C2 - 7902360

AN - SCOPUS:0027359511

VL - 648

SP - 251

EP - 256

JO - Journal of Chromatography

JF - Journal of Chromatography

SN - 0021-9673

IS - 1

ER -