Comparative superoxide dismutase activity studies

B. Matkovics, L. Szabo

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Our results indicate that the various methods for measurement of superoxide dismutase (SOD) activity differ considerably as regards sensitivity. The activity difference may be particularly striking in the determination of the SOD activities of crude homogenates, because of the large number of disturbing factors. We consider the epinephrine-adrenochrome method to be the most suitable for measurement of the SOD activities of crude homogenates and purified enzyme preparations.

Original languageEnglish
Pages (from-to)125-129
Number of pages5
JournalMicrochemical Journal
Volume30
Issue number1
DOIs
Publication statusPublished - 1984

Fingerprint

Superoxide Dismutase
Adrenochrome
Epinephrine
Enzymes

ASJC Scopus subject areas

  • Analytical Chemistry
  • Spectroscopy

Cite this

Comparative superoxide dismutase activity studies. / Matkovics, B.; Szabo, L.

In: Microchemical Journal, Vol. 30, No. 1, 1984, p. 125-129.

Research output: Contribution to journalArticle

Matkovics, B. ; Szabo, L. / Comparative superoxide dismutase activity studies. In: Microchemical Journal. 1984 ; Vol. 30, No. 1. pp. 125-129.
@article{31099f9e5ee042db80941aa93a180ca9,
title = "Comparative superoxide dismutase activity studies",
abstract = "Our results indicate that the various methods for measurement of superoxide dismutase (SOD) activity differ considerably as regards sensitivity. The activity difference may be particularly striking in the determination of the SOD activities of crude homogenates, because of the large number of disturbing factors. We consider the epinephrine-adrenochrome method to be the most suitable for measurement of the SOD activities of crude homogenates and purified enzyme preparations.",
author = "B. Matkovics and L. Szabo",
year = "1984",
doi = "10.1016/0026-265X(84)90145-0",
language = "English",
volume = "30",
pages = "125--129",
journal = "Microchemical Journal",
issn = "0026-265X",
publisher = "Elsevier Inc.",
number = "1",

}

TY - JOUR

T1 - Comparative superoxide dismutase activity studies

AU - Matkovics, B.

AU - Szabo, L.

PY - 1984

Y1 - 1984

N2 - Our results indicate that the various methods for measurement of superoxide dismutase (SOD) activity differ considerably as regards sensitivity. The activity difference may be particularly striking in the determination of the SOD activities of crude homogenates, because of the large number of disturbing factors. We consider the epinephrine-adrenochrome method to be the most suitable for measurement of the SOD activities of crude homogenates and purified enzyme preparations.

AB - Our results indicate that the various methods for measurement of superoxide dismutase (SOD) activity differ considerably as regards sensitivity. The activity difference may be particularly striking in the determination of the SOD activities of crude homogenates, because of the large number of disturbing factors. We consider the epinephrine-adrenochrome method to be the most suitable for measurement of the SOD activities of crude homogenates and purified enzyme preparations.

UR - http://www.scopus.com/inward/record.url?scp=2342482188&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=2342482188&partnerID=8YFLogxK

U2 - 10.1016/0026-265X(84)90145-0

DO - 10.1016/0026-265X(84)90145-0

M3 - Article

VL - 30

SP - 125

EP - 129

JO - Microchemical Journal

JF - Microchemical Journal

SN - 0026-265X

IS - 1

ER -