The use of electron cyclotron resonance ion sources (ECRIS) with permanent magnets for cancer treatment was studied. Investigations shows that a TWT amplifier was employed to found the optimum frequency. It was found that the mirror magnetic fields were 0.59 T at the extraction side and 0.87 T at gas injector side. It was observed that all permanent magnet ECRIS was designed for the next generation cancer treatment facility.

Original languageEnglish
Pages (from-to)1925-1927
Number of pages3
JournalReview of Scientific Instruments
Volume75
Issue number5 PART II
DOIs
Publication statusPublished - May 2004

Fingerprint

Electron cyclotron resonance
Oncology
Ion sources
electron cyclotron resonance
permanent magnets
ion sources
Permanent magnets
therapy
cancer
Carbon
carbon
injectors
Mirrors
amplifiers
Magnetic fields
mirrors
Gases
gases
magnetic fields

ASJC Scopus subject areas

  • Instrumentation
  • Physics and Astronomy (miscellaneous)

Cite this

Muramatsu, M., Kitagawa, A., Sakamoto, Y., Sato, Y., Yamada, S., Ogawa, H., ... Yoshida, Y. (2004). Compact ECR ion source with permanent magnets for carbon therapy. Review of Scientific Instruments, 75(5 PART II), 1925-1927. https://doi.org/10.1063/1.1699521

Compact ECR ion source with permanent magnets for carbon therapy. / Muramatsu, M.; Kitagawa, A.; Sakamoto, Y.; Sato, Y.; Yamada, S.; Ogawa, H.; Drentje, A. G.; Biri, S.; Yoshida, Y.

In: Review of Scientific Instruments, Vol. 75, No. 5 PART II, 05.2004, p. 1925-1927.

Research output: Contribution to journalArticle

Muramatsu, M, Kitagawa, A, Sakamoto, Y, Sato, Y, Yamada, S, Ogawa, H, Drentje, AG, Biri, S & Yoshida, Y 2004, 'Compact ECR ion source with permanent magnets for carbon therapy', Review of Scientific Instruments, vol. 75, no. 5 PART II, pp. 1925-1927. https://doi.org/10.1063/1.1699521
Muramatsu M, Kitagawa A, Sakamoto Y, Sato Y, Yamada S, Ogawa H et al. Compact ECR ion source with permanent magnets for carbon therapy. Review of Scientific Instruments. 2004 May;75(5 PART II):1925-1927. https://doi.org/10.1063/1.1699521
Muramatsu, M. ; Kitagawa, A. ; Sakamoto, Y. ; Sato, Y. ; Yamada, S. ; Ogawa, H. ; Drentje, A. G. ; Biri, S. ; Yoshida, Y. / Compact ECR ion source with permanent magnets for carbon therapy. In: Review of Scientific Instruments. 2004 ; Vol. 75, No. 5 PART II. pp. 1925-1927.
@article{d24d1c7c8d57445492fa688f90869177,
title = "Compact ECR ion source with permanent magnets for carbon therapy",
abstract = "The use of electron cyclotron resonance ion sources (ECRIS) with permanent magnets for cancer treatment was studied. Investigations shows that a TWT amplifier was employed to found the optimum frequency. It was found that the mirror magnetic fields were 0.59 T at the extraction side and 0.87 T at gas injector side. It was observed that all permanent magnet ECRIS was designed for the next generation cancer treatment facility.",
author = "M. Muramatsu and A. Kitagawa and Y. Sakamoto and Y. Sato and S. Yamada and H. Ogawa and Drentje, {A. G.} and S. Biri and Y. Yoshida",
year = "2004",
month = "5",
doi = "10.1063/1.1699521",
language = "English",
volume = "75",
pages = "1925--1927",
journal = "Review of Scientific Instruments",
issn = "0034-6748",
publisher = "American Institute of Physics Publising LLC",
number = "5 PART II",

}

TY - JOUR

T1 - Compact ECR ion source with permanent magnets for carbon therapy

AU - Muramatsu, M.

AU - Kitagawa, A.

AU - Sakamoto, Y.

AU - Sato, Y.

AU - Yamada, S.

AU - Ogawa, H.

AU - Drentje, A. G.

AU - Biri, S.

AU - Yoshida, Y.

PY - 2004/5

Y1 - 2004/5

N2 - The use of electron cyclotron resonance ion sources (ECRIS) with permanent magnets for cancer treatment was studied. Investigations shows that a TWT amplifier was employed to found the optimum frequency. It was found that the mirror magnetic fields were 0.59 T at the extraction side and 0.87 T at gas injector side. It was observed that all permanent magnet ECRIS was designed for the next generation cancer treatment facility.

AB - The use of electron cyclotron resonance ion sources (ECRIS) with permanent magnets for cancer treatment was studied. Investigations shows that a TWT amplifier was employed to found the optimum frequency. It was found that the mirror magnetic fields were 0.59 T at the extraction side and 0.87 T at gas injector side. It was observed that all permanent magnet ECRIS was designed for the next generation cancer treatment facility.

UR - http://www.scopus.com/inward/record.url?scp=3042604622&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=3042604622&partnerID=8YFLogxK

U2 - 10.1063/1.1699521

DO - 10.1063/1.1699521

M3 - Article

AN - SCOPUS:3042604622

VL - 75

SP - 1925

EP - 1927

JO - Review of Scientific Instruments

JF - Review of Scientific Instruments

SN - 0034-6748

IS - 5 PART II

ER -