Combination of a photoacoustic detector with a diffusion sampler for the measurement of water vapor concentration in ethylene glycols for the natural gas industry

Helga Huszár, Z. Bozóki, A. Mohácsi, Gábor Szabó, Sándor Puskás, János Tamás

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

A diffusion sampling based photoacoustic (PA) system for measuring the concentration of water as an impurity in different glycol samples (mono-, di- and triethylene glycol) is presented. Water from the glycol samples diffuses through a sampling membrane into the gaseous phase, where its concentration is determined by a PA system based on a telecommunication type diode laser operating at room temperature. The system was calibrated by measuring the PA signal as a function of the water content of the glycol samples. The sensitivity of the system was found to be dependent on the different glycol types, but in all cases the minimum detectable water concentration was in the low mg/l range. The selectivity of the method was proven by the fact that within the wavelength tuning range of the laser diode, other components, which may diffuse through the membrane, do not generate measurable PA signals. The sensitivity of the system was found to increase exponentially with the temperature of the glycol sample. Altogether, the system has a good potential for industrial applications.

Original languageEnglish
Pages (from-to)600-607
Number of pages8
JournalSensors and Actuators, B: Chemical
Volume119
Issue number2
DOIs
Publication statusPublished - Dec 7 2006

Fingerprint

Ethylene Glycols
samplers
Glycols
Photoacoustic effect
Steam
natural gas
Gas industry
Ethylene glycol
Water vapor
water vapor
glycols
Natural gas
ethylene
industries
Detectors
detectors
Semiconductor lasers
Water
Sampling
Membranes

Keywords

  • Diffusion sampling
  • Ethylene glycol
  • Natural gas industry
  • Photoacoustic

ASJC Scopus subject areas

  • Analytical Chemistry
  • Electrochemistry
  • Electrical and Electronic Engineering

Cite this

Combination of a photoacoustic detector with a diffusion sampler for the measurement of water vapor concentration in ethylene glycols for the natural gas industry. / Huszár, Helga; Bozóki, Z.; Mohácsi, A.; Szabó, Gábor; Puskás, Sándor; Tamás, János.

In: Sensors and Actuators, B: Chemical, Vol. 119, No. 2, 07.12.2006, p. 600-607.

Research output: Contribution to journalArticle

@article{97fd94b150944aadb4f196200a028357,
title = "Combination of a photoacoustic detector with a diffusion sampler for the measurement of water vapor concentration in ethylene glycols for the natural gas industry",
abstract = "A diffusion sampling based photoacoustic (PA) system for measuring the concentration of water as an impurity in different glycol samples (mono-, di- and triethylene glycol) is presented. Water from the glycol samples diffuses through a sampling membrane into the gaseous phase, where its concentration is determined by a PA system based on a telecommunication type diode laser operating at room temperature. The system was calibrated by measuring the PA signal as a function of the water content of the glycol samples. The sensitivity of the system was found to be dependent on the different glycol types, but in all cases the minimum detectable water concentration was in the low mg/l range. The selectivity of the method was proven by the fact that within the wavelength tuning range of the laser diode, other components, which may diffuse through the membrane, do not generate measurable PA signals. The sensitivity of the system was found to increase exponentially with the temperature of the glycol sample. Altogether, the system has a good potential for industrial applications.",
keywords = "Diffusion sampling, Ethylene glycol, Natural gas industry, Photoacoustic",
author = "Helga Husz{\'a}r and Z. Boz{\'o}ki and A. Moh{\'a}csi and G{\'a}bor Szab{\'o} and S{\'a}ndor Pusk{\'a}s and J{\'a}nos Tam{\'a}s",
year = "2006",
month = "12",
day = "7",
doi = "10.1016/j.snb.2006.01.011",
language = "English",
volume = "119",
pages = "600--607",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",
number = "2",

}

TY - JOUR

T1 - Combination of a photoacoustic detector with a diffusion sampler for the measurement of water vapor concentration in ethylene glycols for the natural gas industry

AU - Huszár, Helga

AU - Bozóki, Z.

AU - Mohácsi, A.

AU - Szabó, Gábor

AU - Puskás, Sándor

AU - Tamás, János

PY - 2006/12/7

Y1 - 2006/12/7

N2 - A diffusion sampling based photoacoustic (PA) system for measuring the concentration of water as an impurity in different glycol samples (mono-, di- and triethylene glycol) is presented. Water from the glycol samples diffuses through a sampling membrane into the gaseous phase, where its concentration is determined by a PA system based on a telecommunication type diode laser operating at room temperature. The system was calibrated by measuring the PA signal as a function of the water content of the glycol samples. The sensitivity of the system was found to be dependent on the different glycol types, but in all cases the minimum detectable water concentration was in the low mg/l range. The selectivity of the method was proven by the fact that within the wavelength tuning range of the laser diode, other components, which may diffuse through the membrane, do not generate measurable PA signals. The sensitivity of the system was found to increase exponentially with the temperature of the glycol sample. Altogether, the system has a good potential for industrial applications.

AB - A diffusion sampling based photoacoustic (PA) system for measuring the concentration of water as an impurity in different glycol samples (mono-, di- and triethylene glycol) is presented. Water from the glycol samples diffuses through a sampling membrane into the gaseous phase, where its concentration is determined by a PA system based on a telecommunication type diode laser operating at room temperature. The system was calibrated by measuring the PA signal as a function of the water content of the glycol samples. The sensitivity of the system was found to be dependent on the different glycol types, but in all cases the minimum detectable water concentration was in the low mg/l range. The selectivity of the method was proven by the fact that within the wavelength tuning range of the laser diode, other components, which may diffuse through the membrane, do not generate measurable PA signals. The sensitivity of the system was found to increase exponentially with the temperature of the glycol sample. Altogether, the system has a good potential for industrial applications.

KW - Diffusion sampling

KW - Ethylene glycol

KW - Natural gas industry

KW - Photoacoustic

UR - http://www.scopus.com/inward/record.url?scp=33748903369&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33748903369&partnerID=8YFLogxK

U2 - 10.1016/j.snb.2006.01.011

DO - 10.1016/j.snb.2006.01.011

M3 - Article

VL - 119

SP - 600

EP - 607

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

IS - 2

ER -