Close cathode chamber: Low material budget MWPC

Research output: Contribution to journalArticle

28 Citations (Scopus)

Abstract

Performance of asymmetric-type MWPC-s are presented. In this structure, referred to as Close Cathode Chamber in an earlier study, the material budget is significantly reduced on one hand by the elimination of external support frame, on the other hand by thin detector walls. In this paper it is demonstrated that the outline is compatible with large size detectors (1 m wire length), maintaining mechanical and operation stability, with total weight of 3 kg (including support structure) for a half square meter surface. The detection efficiency and response time is shown to be sufficient for L0 triggering in the ALICE VHMPID layout. Reduced sensitivity to cathode deformations (due to internal overpressure as mechanical strain) is directly demonstrated. On small sized chambers, improvement of position resolution with analog readout is evaluated, reaching 0.09 mm RMS with 2 mm wide cathode segments. Simulation results on signal time evolutions are presented. With the above studies, comparison of classical MWPC-s and the Close Cathode Chamber design is performed in all major aspects.

Original languageEnglish
Pages (from-to)11-18
Number of pages8
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume698
DOIs
Publication statusPublished - Jan 11 2013

Fingerprint

budgets
Cathodes
chambers
cathodes
Detectors
time signals
overpressure
detectors
layouts
readout
elimination
wire
Wire
analogs
sensitivity
simulation

Keywords

  • Low material budget
  • MWPC
  • Tracking detector

ASJC Scopus subject areas

  • Instrumentation
  • Nuclear and High Energy Physics

Cite this

@article{0cffac6446ef4d26b600fe7708e1d33f,
title = "Close cathode chamber: Low material budget MWPC",
abstract = "Performance of asymmetric-type MWPC-s are presented. In this structure, referred to as Close Cathode Chamber in an earlier study, the material budget is significantly reduced on one hand by the elimination of external support frame, on the other hand by thin detector walls. In this paper it is demonstrated that the outline is compatible with large size detectors (1 m wire length), maintaining mechanical and operation stability, with total weight of 3 kg (including support structure) for a half square meter surface. The detection efficiency and response time is shown to be sufficient for L0 triggering in the ALICE VHMPID layout. Reduced sensitivity to cathode deformations (due to internal overpressure as mechanical strain) is directly demonstrated. On small sized chambers, improvement of position resolution with analog readout is evaluated, reaching 0.09 mm RMS with 2 mm wide cathode segments. Simulation results on signal time evolutions are presented. With the above studies, comparison of classical MWPC-s and the Close Cathode Chamber design is performed in all major aspects.",
keywords = "Low material budget, MWPC, Tracking detector",
author = "D. Varga and G. Kiss and G. Hamar and G. Benc{\'e}di",
year = "2013",
month = "1",
day = "11",
doi = "10.1016/j.nima.2012.09.025",
language = "English",
volume = "698",
pages = "11--18",
journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
issn = "0168-9002",
publisher = "Elsevier",

}

TY - JOUR

T1 - Close cathode chamber

T2 - Low material budget MWPC

AU - Varga, D.

AU - Kiss, G.

AU - Hamar, G.

AU - Bencédi, G.

PY - 2013/1/11

Y1 - 2013/1/11

N2 - Performance of asymmetric-type MWPC-s are presented. In this structure, referred to as Close Cathode Chamber in an earlier study, the material budget is significantly reduced on one hand by the elimination of external support frame, on the other hand by thin detector walls. In this paper it is demonstrated that the outline is compatible with large size detectors (1 m wire length), maintaining mechanical and operation stability, with total weight of 3 kg (including support structure) for a half square meter surface. The detection efficiency and response time is shown to be sufficient for L0 triggering in the ALICE VHMPID layout. Reduced sensitivity to cathode deformations (due to internal overpressure as mechanical strain) is directly demonstrated. On small sized chambers, improvement of position resolution with analog readout is evaluated, reaching 0.09 mm RMS with 2 mm wide cathode segments. Simulation results on signal time evolutions are presented. With the above studies, comparison of classical MWPC-s and the Close Cathode Chamber design is performed in all major aspects.

AB - Performance of asymmetric-type MWPC-s are presented. In this structure, referred to as Close Cathode Chamber in an earlier study, the material budget is significantly reduced on one hand by the elimination of external support frame, on the other hand by thin detector walls. In this paper it is demonstrated that the outline is compatible with large size detectors (1 m wire length), maintaining mechanical and operation stability, with total weight of 3 kg (including support structure) for a half square meter surface. The detection efficiency and response time is shown to be sufficient for L0 triggering in the ALICE VHMPID layout. Reduced sensitivity to cathode deformations (due to internal overpressure as mechanical strain) is directly demonstrated. On small sized chambers, improvement of position resolution with analog readout is evaluated, reaching 0.09 mm RMS with 2 mm wide cathode segments. Simulation results on signal time evolutions are presented. With the above studies, comparison of classical MWPC-s and the Close Cathode Chamber design is performed in all major aspects.

KW - Low material budget

KW - MWPC

KW - Tracking detector

UR - http://www.scopus.com/inward/record.url?scp=84867637311&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84867637311&partnerID=8YFLogxK

U2 - 10.1016/j.nima.2012.09.025

DO - 10.1016/j.nima.2012.09.025

M3 - Article

AN - SCOPUS:84867637311

VL - 698

SP - 11

EP - 18

JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

SN - 0168-9002

ER -