Can the ions be guided with MeV/amu energies? The case of the 1 MeV proton microbeam

K. Tőkési, I. Rajta, G. U L Nagy, R. J. Bereczky

Research output: Contribution to journalArticle

Abstract

The transmission of 1MeV proton microbeam through aTeflon microcapillary was studied. Using the suitable combination of the capillary temperature and beam intensity we identified three different regions in the transmission as a function of time. In the third region stable guided transmission was obtained where the dominant contribution of the transmitted protons did not suffer energy loss.

Original languageEnglish
Article number132019
JournalJournal of Physics: Conference Series
Volume488
Issue numberSECTION 13
DOIs
Publication statusPublished - 2014

Fingerprint

microbeams
protons
ions
energy
energy dissipation
temperature

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Can the ions be guided with MeV/amu energies? The case of the 1 MeV proton microbeam. / Tőkési, K.; Rajta, I.; Nagy, G. U L; Bereczky, R. J.

In: Journal of Physics: Conference Series, Vol. 488, No. SECTION 13, 132019, 2014.

Research output: Contribution to journalArticle

@article{b191db3d40df42829ea01128ec3be212,
title = "Can the ions be guided with MeV/amu energies? The case of the 1 MeV proton microbeam",
abstract = "The transmission of 1MeV proton microbeam through aTeflon microcapillary was studied. Using the suitable combination of the capillary temperature and beam intensity we identified three different regions in the transmission as a function of time. In the third region stable guided transmission was obtained where the dominant contribution of the transmitted protons did not suffer energy loss.",
author = "K. Tők{\'e}si and I. Rajta and Nagy, {G. U L} and Bereczky, {R. J.}",
year = "2014",
doi = "10.1088/1742-6596/488/13/132019",
language = "English",
volume = "488",
journal = "Journal of Physics: Conference Series",
issn = "1742-6588",
publisher = "IOP Publishing Ltd.",
number = "SECTION 13",

}

TY - JOUR

T1 - Can the ions be guided with MeV/amu energies? The case of the 1 MeV proton microbeam

AU - Tőkési, K.

AU - Rajta, I.

AU - Nagy, G. U L

AU - Bereczky, R. J.

PY - 2014

Y1 - 2014

N2 - The transmission of 1MeV proton microbeam through aTeflon microcapillary was studied. Using the suitable combination of the capillary temperature and beam intensity we identified three different regions in the transmission as a function of time. In the third region stable guided transmission was obtained where the dominant contribution of the transmitted protons did not suffer energy loss.

AB - The transmission of 1MeV proton microbeam through aTeflon microcapillary was studied. Using the suitable combination of the capillary temperature and beam intensity we identified three different regions in the transmission as a function of time. In the third region stable guided transmission was obtained where the dominant contribution of the transmitted protons did not suffer energy loss.

UR - http://www.scopus.com/inward/record.url?scp=84903696638&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84903696638&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/488/13/132019

DO - 10.1088/1742-6596/488/13/132019

M3 - Article

VL - 488

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - SECTION 13

M1 - 132019

ER -