Avoiding dangerous overspeed in ultrahighspeed turbine-generator set applied for waste and renewable energy recovery

Peter Stumpf, Rafael K. Járdán, I. Nagy

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The paper is concerned with the study of a nonlinear speed control loop of an ultrahighspeed turbine-generator set applied in waste and renewable energy recovery system. The target of the study is to compare two speed control configurations and to select one configuration and its optimum control parameters on the basis of a series of systematic simulation investigations. Large signal transient responses had to be investigated beside the small signal analysis due to the strong nonlinearity of the induction generator.

Original languageEnglish
Title of host publicationIEEE International Symposium on Industrial Electronics
Pages831-836
Number of pages6
DOIs
Publication statusPublished - 2009
EventIEEE International Symposium on Industrial Electronics, IEEE ISIE 2009 - Seoul, Korea, Republic of
Duration: Jul 5 2009Jul 8 2009

Other

OtherIEEE International Symposium on Industrial Electronics, IEEE ISIE 2009
CountryKorea, Republic of
CitySeoul
Period7/5/097/8/09

Fingerprint

Turbogenerators
Speed control
Recovery
Asynchronous generators
Signal analysis
Transient analysis

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Control and Systems Engineering

Cite this

Stumpf, P., Járdán, R. K., & Nagy, I. (2009). Avoiding dangerous overspeed in ultrahighspeed turbine-generator set applied for waste and renewable energy recovery. In IEEE International Symposium on Industrial Electronics (pp. 831-836). [5222727] https://doi.org/10.1109/ISIE.2009.5222727

Avoiding dangerous overspeed in ultrahighspeed turbine-generator set applied for waste and renewable energy recovery. / Stumpf, Peter; Járdán, Rafael K.; Nagy, I.

IEEE International Symposium on Industrial Electronics. 2009. p. 831-836 5222727.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Stumpf, P, Járdán, RK & Nagy, I 2009, Avoiding dangerous overspeed in ultrahighspeed turbine-generator set applied for waste and renewable energy recovery. in IEEE International Symposium on Industrial Electronics., 5222727, pp. 831-836, IEEE International Symposium on Industrial Electronics, IEEE ISIE 2009, Seoul, Korea, Republic of, 7/5/09. https://doi.org/10.1109/ISIE.2009.5222727
Stumpf P, Járdán RK, Nagy I. Avoiding dangerous overspeed in ultrahighspeed turbine-generator set applied for waste and renewable energy recovery. In IEEE International Symposium on Industrial Electronics. 2009. p. 831-836. 5222727 https://doi.org/10.1109/ISIE.2009.5222727
Stumpf, Peter ; Járdán, Rafael K. ; Nagy, I. / Avoiding dangerous overspeed in ultrahighspeed turbine-generator set applied for waste and renewable energy recovery. IEEE International Symposium on Industrial Electronics. 2009. pp. 831-836
@inproceedings{90e3aa7143e2443fae00489dd856c8c3,
title = "Avoiding dangerous overspeed in ultrahighspeed turbine-generator set applied for waste and renewable energy recovery",
abstract = "The paper is concerned with the study of a nonlinear speed control loop of an ultrahighspeed turbine-generator set applied in waste and renewable energy recovery system. The target of the study is to compare two speed control configurations and to select one configuration and its optimum control parameters on the basis of a series of systematic simulation investigations. Large signal transient responses had to be investigated beside the small signal analysis due to the strong nonlinearity of the induction generator.",
author = "Peter Stumpf and J{\'a}rd{\'a}n, {Rafael K.} and I. Nagy",
year = "2009",
doi = "10.1109/ISIE.2009.5222727",
language = "English",
isbn = "9781424443499",
pages = "831--836",
booktitle = "IEEE International Symposium on Industrial Electronics",

}

TY - GEN

T1 - Avoiding dangerous overspeed in ultrahighspeed turbine-generator set applied for waste and renewable energy recovery

AU - Stumpf, Peter

AU - Járdán, Rafael K.

AU - Nagy, I.

PY - 2009

Y1 - 2009

N2 - The paper is concerned with the study of a nonlinear speed control loop of an ultrahighspeed turbine-generator set applied in waste and renewable energy recovery system. The target of the study is to compare two speed control configurations and to select one configuration and its optimum control parameters on the basis of a series of systematic simulation investigations. Large signal transient responses had to be investigated beside the small signal analysis due to the strong nonlinearity of the induction generator.

AB - The paper is concerned with the study of a nonlinear speed control loop of an ultrahighspeed turbine-generator set applied in waste and renewable energy recovery system. The target of the study is to compare two speed control configurations and to select one configuration and its optimum control parameters on the basis of a series of systematic simulation investigations. Large signal transient responses had to be investigated beside the small signal analysis due to the strong nonlinearity of the induction generator.

UR - http://www.scopus.com/inward/record.url?scp=77950117601&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77950117601&partnerID=8YFLogxK

U2 - 10.1109/ISIE.2009.5222727

DO - 10.1109/ISIE.2009.5222727

M3 - Conference contribution

AN - SCOPUS:77950117601

SN - 9781424443499

SP - 831

EP - 836

BT - IEEE International Symposium on Industrial Electronics

ER -