Assessment of reproducibility of exhaled hydrogen peroxide concentration and the effect of breathing pattern in healthy subjects

Reka Gajdocsi, Andras Bikov, B. Antus, I. Horváth, Peter J. Barnes, Sergei A. Kharitonov

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

Background: Hydrogen peroxide (H 2O 2) is detectable in exhaled breath condensate (EBC) and has been proposed to be a surrogate marker of oxidative stress in the airways. In this study we tested whether the breathing pattern during EBC collection influences the concentration of exhaled H 2O 2. Methods: EBC was collected during (1) tidal breathing and (2) breathing with increased tidal volume for 10 min from 16 healthy volunteers. On-line H 2O 2 measurement was performed by the EcoCheckTM biosensor system. Repeated measurements were also conducted to assess intrasubject reproducibility. Results: Minute ventilation, tidal volume, expiratory flow rate were all increased significantly when subjects were asked to perform breathing with increased tidal volume. In parallel, EBC volume increased (1413 ± 59 vs. 1959 ± 71 mL, p <0.001), whereas exhaled H 2O 2 levels decreased significantly (1400 ± 170 vs. 840 ± 130 nmol/L, p <0.001). H 2O 2 levels did not correlate with any individual breathing parameters (p>0.05). Assessment of intersubject variability of H 2O 2 measurements during the two types of breathing revealed a coefficient of variation of 49 and 54%, respectively. The EBC H 2O 2 measurement was highly reproducible (888 ± 176 vs. 874 ± 156 nmol/L) as tested during normal breathing. Conclusions: These data demonstrate that the concentration of H 2O 2 in EBC depends on the ventilatory pattern during sample collection that has to be taken into consideration in all EBC H 2O 2 assays.

Original languageEnglish
Pages (from-to)271-275
Number of pages5
JournalJournal of Aerosol Medicine and Pulmonary Drug Delivery
Volume24
Issue number6
DOIs
Publication statusPublished - Dec 1 2011

Fingerprint

Hydrogen Peroxide
Healthy Volunteers
Respiration
Tidal Volume
Biosensing Techniques
Ventilation
Oxidative Stress
Biomarkers

Keywords

  • breathing
  • exhaled breath condensate
  • hydrogen peroxide
  • pattern
  • variability

ASJC Scopus subject areas

  • Pulmonary and Respiratory Medicine
  • Pharmacology (medical)
  • Pharmaceutical Science

Cite this

Assessment of reproducibility of exhaled hydrogen peroxide concentration and the effect of breathing pattern in healthy subjects. / Gajdocsi, Reka; Bikov, Andras; Antus, B.; Horváth, I.; Barnes, Peter J.; Kharitonov, Sergei A.

In: Journal of Aerosol Medicine and Pulmonary Drug Delivery, Vol. 24, No. 6, 01.12.2011, p. 271-275.

Research output: Contribution to journalArticle

@article{51b724d6cfbe49d9945a4b9fee1ec96c,
title = "Assessment of reproducibility of exhaled hydrogen peroxide concentration and the effect of breathing pattern in healthy subjects",
abstract = "Background: Hydrogen peroxide (H 2O 2) is detectable in exhaled breath condensate (EBC) and has been proposed to be a surrogate marker of oxidative stress in the airways. In this study we tested whether the breathing pattern during EBC collection influences the concentration of exhaled H 2O 2. Methods: EBC was collected during (1) tidal breathing and (2) breathing with increased tidal volume for 10 min from 16 healthy volunteers. On-line H 2O 2 measurement was performed by the EcoCheckTM biosensor system. Repeated measurements were also conducted to assess intrasubject reproducibility. Results: Minute ventilation, tidal volume, expiratory flow rate were all increased significantly when subjects were asked to perform breathing with increased tidal volume. In parallel, EBC volume increased (1413 ± 59 vs. 1959 ± 71 mL, p <0.001), whereas exhaled H 2O 2 levels decreased significantly (1400 ± 170 vs. 840 ± 130 nmol/L, p <0.001). H 2O 2 levels did not correlate with any individual breathing parameters (p>0.05). Assessment of intersubject variability of H 2O 2 measurements during the two types of breathing revealed a coefficient of variation of 49 and 54{\%}, respectively. The EBC H 2O 2 measurement was highly reproducible (888 ± 176 vs. 874 ± 156 nmol/L) as tested during normal breathing. Conclusions: These data demonstrate that the concentration of H 2O 2 in EBC depends on the ventilatory pattern during sample collection that has to be taken into consideration in all EBC H 2O 2 assays.",
keywords = "breathing, exhaled breath condensate, hydrogen peroxide, pattern, variability",
author = "Reka Gajdocsi and Andras Bikov and B. Antus and I. Horv{\'a}th and Barnes, {Peter J.} and Kharitonov, {Sergei A.}",
year = "2011",
month = "12",
day = "1",
doi = "10.1089/jamp.2011.0875",
language = "English",
volume = "24",
pages = "271--275",
journal = "Journal of Aerosol Medicine and Pulmonary Drug Delivery",
issn = "1941-2711",
publisher = "Mary Ann Liebert Inc.",
number = "6",

}

TY - JOUR

T1 - Assessment of reproducibility of exhaled hydrogen peroxide concentration and the effect of breathing pattern in healthy subjects

AU - Gajdocsi, Reka

AU - Bikov, Andras

AU - Antus, B.

AU - Horváth, I.

AU - Barnes, Peter J.

AU - Kharitonov, Sergei A.

PY - 2011/12/1

Y1 - 2011/12/1

N2 - Background: Hydrogen peroxide (H 2O 2) is detectable in exhaled breath condensate (EBC) and has been proposed to be a surrogate marker of oxidative stress in the airways. In this study we tested whether the breathing pattern during EBC collection influences the concentration of exhaled H 2O 2. Methods: EBC was collected during (1) tidal breathing and (2) breathing with increased tidal volume for 10 min from 16 healthy volunteers. On-line H 2O 2 measurement was performed by the EcoCheckTM biosensor system. Repeated measurements were also conducted to assess intrasubject reproducibility. Results: Minute ventilation, tidal volume, expiratory flow rate were all increased significantly when subjects were asked to perform breathing with increased tidal volume. In parallel, EBC volume increased (1413 ± 59 vs. 1959 ± 71 mL, p <0.001), whereas exhaled H 2O 2 levels decreased significantly (1400 ± 170 vs. 840 ± 130 nmol/L, p <0.001). H 2O 2 levels did not correlate with any individual breathing parameters (p>0.05). Assessment of intersubject variability of H 2O 2 measurements during the two types of breathing revealed a coefficient of variation of 49 and 54%, respectively. The EBC H 2O 2 measurement was highly reproducible (888 ± 176 vs. 874 ± 156 nmol/L) as tested during normal breathing. Conclusions: These data demonstrate that the concentration of H 2O 2 in EBC depends on the ventilatory pattern during sample collection that has to be taken into consideration in all EBC H 2O 2 assays.

AB - Background: Hydrogen peroxide (H 2O 2) is detectable in exhaled breath condensate (EBC) and has been proposed to be a surrogate marker of oxidative stress in the airways. In this study we tested whether the breathing pattern during EBC collection influences the concentration of exhaled H 2O 2. Methods: EBC was collected during (1) tidal breathing and (2) breathing with increased tidal volume for 10 min from 16 healthy volunteers. On-line H 2O 2 measurement was performed by the EcoCheckTM biosensor system. Repeated measurements were also conducted to assess intrasubject reproducibility. Results: Minute ventilation, tidal volume, expiratory flow rate were all increased significantly when subjects were asked to perform breathing with increased tidal volume. In parallel, EBC volume increased (1413 ± 59 vs. 1959 ± 71 mL, p <0.001), whereas exhaled H 2O 2 levels decreased significantly (1400 ± 170 vs. 840 ± 130 nmol/L, p <0.001). H 2O 2 levels did not correlate with any individual breathing parameters (p>0.05). Assessment of intersubject variability of H 2O 2 measurements during the two types of breathing revealed a coefficient of variation of 49 and 54%, respectively. The EBC H 2O 2 measurement was highly reproducible (888 ± 176 vs. 874 ± 156 nmol/L) as tested during normal breathing. Conclusions: These data demonstrate that the concentration of H 2O 2 in EBC depends on the ventilatory pattern during sample collection that has to be taken into consideration in all EBC H 2O 2 assays.

KW - breathing

KW - exhaled breath condensate

KW - hydrogen peroxide

KW - pattern

KW - variability

UR - http://www.scopus.com/inward/record.url?scp=82955246706&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=82955246706&partnerID=8YFLogxK

U2 - 10.1089/jamp.2011.0875

DO - 10.1089/jamp.2011.0875

M3 - Article

C2 - 21689021

AN - SCOPUS:82955246706

VL - 24

SP - 271

EP - 275

JO - Journal of Aerosol Medicine and Pulmonary Drug Delivery

JF - Journal of Aerosol Medicine and Pulmonary Drug Delivery

SN - 1941-2711

IS - 6

ER -