Application of fuzzy logic in hemodialysis equipment

Jozsef Klespitz, Márta Takács, L. Kovács

Research output: Chapter in Book/Report/Conference proceedingConference contribution

8 Citations (Scopus)

Abstract

In hemodialysis machines peristaltic pumps are responsible for the transfer of fluids. These pumps can only deliver the solutions with significant error, due to the deviation of the pump head and due to production errors. Previous work focused on system identification and fluid flow control by a PID controller. In this paper the goal is to replace the PID controller with an adaptive fuzzy controller. Furthermore, the use of integral component for error signal rejection is examined as input to the fuzzy logic system. The mentioned controllers are compared through appropriate aspects and the paper ends with discussion of the behavior of the adaptive fuzzy controller on the real system.

Original languageEnglish
Title of host publicationINES 2014 - IEEE 18th International Conference on Intelligent Engineering Systems, Proceedings
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages169-173
Number of pages5
ISBN (Print)9781479946150
DOIs
Publication statusPublished - Sep 24 2014
Event18th IEEE International Conference on Intelligent Engineering Systems, INES 2014 - Tihany, Hungary
Duration: Jul 3 2014Jul 5 2014

Other

Other18th IEEE International Conference on Intelligent Engineering Systems, INES 2014
CountryHungary
CityTihany
Period7/3/147/5/14

Fingerprint

Fuzzy Logic
Fuzzy logic
Pump
PID Controller
Fuzzy Controller
Controllers
Pumps
Fuzzy Logic System
Flow Control
System Identification
Rejection
Fluid Flow
Deviation
Controller
Fluid
Flow control
Flow of fluids
Identification (control systems)
Fluids

ASJC Scopus subject areas

  • Software
  • Artificial Intelligence
  • Applied Mathematics
  • Theoretical Computer Science

Cite this

Klespitz, J., Takács, M., & Kovács, L. (2014). Application of fuzzy logic in hemodialysis equipment. In INES 2014 - IEEE 18th International Conference on Intelligent Engineering Systems, Proceedings (pp. 169-173). [6909363] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/INES.2014.6909363

Application of fuzzy logic in hemodialysis equipment. / Klespitz, Jozsef; Takács, Márta; Kovács, L.

INES 2014 - IEEE 18th International Conference on Intelligent Engineering Systems, Proceedings. Institute of Electrical and Electronics Engineers Inc., 2014. p. 169-173 6909363.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Klespitz, J, Takács, M & Kovács, L 2014, Application of fuzzy logic in hemodialysis equipment. in INES 2014 - IEEE 18th International Conference on Intelligent Engineering Systems, Proceedings., 6909363, Institute of Electrical and Electronics Engineers Inc., pp. 169-173, 18th IEEE International Conference on Intelligent Engineering Systems, INES 2014, Tihany, Hungary, 7/3/14. https://doi.org/10.1109/INES.2014.6909363
Klespitz J, Takács M, Kovács L. Application of fuzzy logic in hemodialysis equipment. In INES 2014 - IEEE 18th International Conference on Intelligent Engineering Systems, Proceedings. Institute of Electrical and Electronics Engineers Inc. 2014. p. 169-173. 6909363 https://doi.org/10.1109/INES.2014.6909363
Klespitz, Jozsef ; Takács, Márta ; Kovács, L. / Application of fuzzy logic in hemodialysis equipment. INES 2014 - IEEE 18th International Conference on Intelligent Engineering Systems, Proceedings. Institute of Electrical and Electronics Engineers Inc., 2014. pp. 169-173
@inproceedings{bf33e4d7876f4e31b6d283d7b42e7fcc,
title = "Application of fuzzy logic in hemodialysis equipment",
abstract = "In hemodialysis machines peristaltic pumps are responsible for the transfer of fluids. These pumps can only deliver the solutions with significant error, due to the deviation of the pump head and due to production errors. Previous work focused on system identification and fluid flow control by a PID controller. In this paper the goal is to replace the PID controller with an adaptive fuzzy controller. Furthermore, the use of integral component for error signal rejection is examined as input to the fuzzy logic system. The mentioned controllers are compared through appropriate aspects and the paper ends with discussion of the behavior of the adaptive fuzzy controller on the real system.",
author = "Jozsef Klespitz and M{\'a}rta Tak{\'a}cs and L. Kov{\'a}cs",
year = "2014",
month = "9",
day = "24",
doi = "10.1109/INES.2014.6909363",
language = "English",
isbn = "9781479946150",
pages = "169--173",
booktitle = "INES 2014 - IEEE 18th International Conference on Intelligent Engineering Systems, Proceedings",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - Application of fuzzy logic in hemodialysis equipment

AU - Klespitz, Jozsef

AU - Takács, Márta

AU - Kovács, L.

PY - 2014/9/24

Y1 - 2014/9/24

N2 - In hemodialysis machines peristaltic pumps are responsible for the transfer of fluids. These pumps can only deliver the solutions with significant error, due to the deviation of the pump head and due to production errors. Previous work focused on system identification and fluid flow control by a PID controller. In this paper the goal is to replace the PID controller with an adaptive fuzzy controller. Furthermore, the use of integral component for error signal rejection is examined as input to the fuzzy logic system. The mentioned controllers are compared through appropriate aspects and the paper ends with discussion of the behavior of the adaptive fuzzy controller on the real system.

AB - In hemodialysis machines peristaltic pumps are responsible for the transfer of fluids. These pumps can only deliver the solutions with significant error, due to the deviation of the pump head and due to production errors. Previous work focused on system identification and fluid flow control by a PID controller. In this paper the goal is to replace the PID controller with an adaptive fuzzy controller. Furthermore, the use of integral component for error signal rejection is examined as input to the fuzzy logic system. The mentioned controllers are compared through appropriate aspects and the paper ends with discussion of the behavior of the adaptive fuzzy controller on the real system.

UR - http://www.scopus.com/inward/record.url?scp=84908655722&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84908655722&partnerID=8YFLogxK

U2 - 10.1109/INES.2014.6909363

DO - 10.1109/INES.2014.6909363

M3 - Conference contribution

SN - 9781479946150

SP - 169

EP - 173

BT - INES 2014 - IEEE 18th International Conference on Intelligent Engineering Systems, Proceedings

PB - Institute of Electrical and Electronics Engineers Inc.

ER -