Application of an immobilized glucose oxidase-peroxidase system for the determination of glucose in fish blood sera

M. Abraham, J. Nemcsok, B. Szajáni

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

An immobilized enzyme reactor usable in a flow injection system has been developed for the determination of glucose concentration in biological fluids. The system is suitable for continuous analyses of the glucose level in fish blood serum, proposed as a sensitive indicator of environmental stress.

Original languageEnglish
Pages (from-to)53-61
Number of pages9
JournalInternational Journal of Environmental Analytical Chemistry
Volume50
Issue number1
DOIs
Publication statusPublished - Apr 1 1993

Fingerprint

glucose oxidase
Glucose Oxidase
Glucose oxidase
blood serum
Fish
Peroxidase
Glucose
serum
peroxidase
Fishes
glucose
Blood
blood
Immobilized Enzymes
immobilized enzymes
environmental indicators
fish
environmental stress
Serum
Enzymes

Keywords

  • Blood glucose
  • environmental pollution
  • flow injection analysis
  • immobilized enzymes

ASJC Scopus subject areas

  • Soil Science
  • Analytical Chemistry
  • Health, Toxicology and Mutagenesis
  • Waste Management and Disposal
  • Public Health, Environmental and Occupational Health
  • Water Science and Technology
  • Pollution
  • Environmental Chemistry

Cite this

@article{25c9b241f3864cda905f297303809092,
title = "Application of an immobilized glucose oxidase-peroxidase system for the determination of glucose in fish blood sera",
abstract = "An immobilized enzyme reactor usable in a flow injection system has been developed for the determination of glucose concentration in biological fluids. The system is suitable for continuous analyses of the glucose level in fish blood serum, proposed as a sensitive indicator of environmental stress.",
keywords = "Blood glucose, environmental pollution, flow injection analysis, immobilized enzymes",
author = "M. Abraham and J. Nemcsok and B. Szaj{\'a}ni",
year = "1993",
month = "4",
day = "1",
doi = "10.1080/03067319308027583",
language = "English",
volume = "50",
pages = "53--61",
journal = "International Journal of Environmental Analytical Chemistry",
issn = "0306-7319",
publisher = "Taylor and Francis Ltd.",
number = "1",

}

TY - JOUR

T1 - Application of an immobilized glucose oxidase-peroxidase system for the determination of glucose in fish blood sera

AU - Abraham, M.

AU - Nemcsok, J.

AU - Szajáni, B.

PY - 1993/4/1

Y1 - 1993/4/1

N2 - An immobilized enzyme reactor usable in a flow injection system has been developed for the determination of glucose concentration in biological fluids. The system is suitable for continuous analyses of the glucose level in fish blood serum, proposed as a sensitive indicator of environmental stress.

AB - An immobilized enzyme reactor usable in a flow injection system has been developed for the determination of glucose concentration in biological fluids. The system is suitable for continuous analyses of the glucose level in fish blood serum, proposed as a sensitive indicator of environmental stress.

KW - Blood glucose

KW - environmental pollution

KW - flow injection analysis

KW - immobilized enzymes

UR - http://www.scopus.com/inward/record.url?scp=0343739664&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0343739664&partnerID=8YFLogxK

U2 - 10.1080/03067319308027583

DO - 10.1080/03067319308027583

M3 - Article

AN - SCOPUS:0343739664

VL - 50

SP - 53

EP - 61

JO - International Journal of Environmental Analytical Chemistry

JF - International Journal of Environmental Analytical Chemistry

SN - 0306-7319

IS - 1

ER -