Application of alumina column for the purity control of mono- and ditetrazolium salts

Ágnes Kósa, E. Forgács, Sándor Balogh

Research output: Contribution to journalArticle

Abstract

The purity of the 16 mono- and ditetrazolium salts were studied on an alumina column in various eluent system such as: mixture of 1,4-dioxan and acetonitrile, 2+98 v/v, and mixture of 1,4-dioxan, methanol and carbon tetrachloride, 2+88+10 v/v, using the diode array detection to charactarize the impurities. Stepwise regression analysis was applied to find molecular parameters significantly influencing the retention of the main components. Alumina support was suitable for the separation of mono- and ditetrazolium salts, and the applied methods were appropriate for the purity check of the investigated compounds. The results of stepwise regression analysis indicates that different molecular parameters influence the retention in the eluent systems.

Original languageEnglish
Pages (from-to)107-116
Number of pages10
JournalChemia Analityczna
Volume43
Issue number1
Publication statusPublished - 1998

Fingerprint

Aluminum Oxide
Regression analysis
Salts
Carbon Tetrachloride
Methanol
Diodes
Impurities
1,4-dioxane
acetonitrile

Keywords

  • Alumina column
  • High Performance Liquid Chromatography
  • Mono- and ditetrazolium salts
  • Purity control

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Application of alumina column for the purity control of mono- and ditetrazolium salts. / Kósa, Ágnes; Forgács, E.; Balogh, Sándor.

In: Chemia Analityczna, Vol. 43, No. 1, 1998, p. 107-116.

Research output: Contribution to journalArticle

@article{72e095fd65b4428c8d8510368aab994b,
title = "Application of alumina column for the purity control of mono- and ditetrazolium salts",
abstract = "The purity of the 16 mono- and ditetrazolium salts were studied on an alumina column in various eluent system such as: mixture of 1,4-dioxan and acetonitrile, 2+98 v/v, and mixture of 1,4-dioxan, methanol and carbon tetrachloride, 2+88+10 v/v, using the diode array detection to charactarize the impurities. Stepwise regression analysis was applied to find molecular parameters significantly influencing the retention of the main components. Alumina support was suitable for the separation of mono- and ditetrazolium salts, and the applied methods were appropriate for the purity check of the investigated compounds. The results of stepwise regression analysis indicates that different molecular parameters influence the retention in the eluent systems.",
keywords = "Alumina column, High Performance Liquid Chromatography, Mono- and ditetrazolium salts, Purity control",
author = "{\'A}gnes K{\'o}sa and E. Forg{\'a}cs and S{\'a}ndor Balogh",
year = "1998",
language = "English",
volume = "43",
pages = "107--116",
journal = "Chemical Analysis",
issn = "0009-2223",
publisher = "Polskie Towarzystwo Chemiczne",
number = "1",

}

TY - JOUR

T1 - Application of alumina column for the purity control of mono- and ditetrazolium salts

AU - Kósa, Ágnes

AU - Forgács, E.

AU - Balogh, Sándor

PY - 1998

Y1 - 1998

N2 - The purity of the 16 mono- and ditetrazolium salts were studied on an alumina column in various eluent system such as: mixture of 1,4-dioxan and acetonitrile, 2+98 v/v, and mixture of 1,4-dioxan, methanol and carbon tetrachloride, 2+88+10 v/v, using the diode array detection to charactarize the impurities. Stepwise regression analysis was applied to find molecular parameters significantly influencing the retention of the main components. Alumina support was suitable for the separation of mono- and ditetrazolium salts, and the applied methods were appropriate for the purity check of the investigated compounds. The results of stepwise regression analysis indicates that different molecular parameters influence the retention in the eluent systems.

AB - The purity of the 16 mono- and ditetrazolium salts were studied on an alumina column in various eluent system such as: mixture of 1,4-dioxan and acetonitrile, 2+98 v/v, and mixture of 1,4-dioxan, methanol and carbon tetrachloride, 2+88+10 v/v, using the diode array detection to charactarize the impurities. Stepwise regression analysis was applied to find molecular parameters significantly influencing the retention of the main components. Alumina support was suitable for the separation of mono- and ditetrazolium salts, and the applied methods were appropriate for the purity check of the investigated compounds. The results of stepwise regression analysis indicates that different molecular parameters influence the retention in the eluent systems.

KW - Alumina column

KW - High Performance Liquid Chromatography

KW - Mono- and ditetrazolium salts

KW - Purity control

UR - http://www.scopus.com/inward/record.url?scp=0040575183&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0040575183&partnerID=8YFLogxK

M3 - Article

VL - 43

SP - 107

EP - 116

JO - Chemical Analysis

JF - Chemical Analysis

SN - 0009-2223

IS - 1

ER -