Bifurkationsprothese: Dacron versus Teflon (PTFE) - Präliminäre Ergebnisse einer prospektiven randomisierten Studie

Translated title of the contribution: Aorto-Y-bifurcationgraft: Dacron versus PTFE -preliminary results of a prospective randomized study

J. Karner, P. Polterauer, G. Kretschmer, F. Piza, M. Schemper

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

After 3 years a preliminary evaluation of a prospective randomized study between PTFE-Y- and Dacron-Y-grafts in regard to function rate, complication and quality of material was performed. Both, function rate and complications showed no significant differences between both groups. In all patients with graft limb occlusion (1 early and 4 later occlusions) the function was gained by successful thrombectomy. Today Dacron-Y-prosthesis is available as collagen coated dacron double veloure graft, so presenting the same most important advantage PTFE prosthesis did (no preclotting). In cause of those above mentioned material characteristics both grafts seem to be equal in quality.

Original languageGerman
Pages (from-to)8-10
Number of pages3
JournalActa Chirurgica Austriaca
Volume19
Issue number1
DOIs
Publication statusPublished - Jan 1987

Fingerprint

Polyethylene Terephthalates
Polytetrafluoroethylene
Prospective Studies
Transplants
Prostheses and Implants
Thrombectomy
Collagen
Extremities

Keywords

  • Aortic aneurysma
  • aorto-ilica occlusion disease
  • Dacron-Y-prosthesis
  • PTFE-Y-prosthesis

ASJC Scopus subject areas

  • Surgery

Cite this

Bifurkationsprothese : Dacron versus Teflon (PTFE) - Präliminäre Ergebnisse einer prospektiven randomisierten Studie. / Karner, J.; Polterauer, P.; Kretschmer, G.; Piza, F.; Schemper, M.

In: Acta Chirurgica Austriaca, Vol. 19, No. 1, 01.1987, p. 8-10.

Research output: Contribution to journalArticle

Karner, J. ; Polterauer, P. ; Kretschmer, G. ; Piza, F. ; Schemper, M. / Bifurkationsprothese : Dacron versus Teflon (PTFE) - Präliminäre Ergebnisse einer prospektiven randomisierten Studie. In: Acta Chirurgica Austriaca. 1987 ; Vol. 19, No. 1. pp. 8-10.
@article{67f39d8a77ec4494936bca350cb6cde0,
title = "Bifurkationsprothese: Dacron versus Teflon (PTFE) - Pr{\"a}limin{\"a}re Ergebnisse einer prospektiven randomisierten Studie",
abstract = "After 3 years a preliminary evaluation of a prospective randomized study between PTFE-Y- and Dacron-Y-grafts in regard to function rate, complication and quality of material was performed. Both, function rate and complications showed no significant differences between both groups. In all patients with graft limb occlusion (1 early and 4 later occlusions) the function was gained by successful thrombectomy. Today Dacron-Y-prosthesis is available as collagen coated dacron double veloure graft, so presenting the same most important advantage PTFE prosthesis did (no preclotting). In cause of those above mentioned material characteristics both grafts seem to be equal in quality.",
keywords = "Aortic aneurysma, aorto-ilica occlusion disease, Dacron-Y-prosthesis, PTFE-Y-prosthesis",
author = "J. Karner and P. Polterauer and G. Kretschmer and F. Piza and M. Schemper",
year = "1987",
month = "1",
doi = "10.1007/BF02658284",
language = "German",
volume = "19",
pages = "8--10",
journal = "European Surgery",
issn = "1682-8631",
publisher = "Springer Wien",
number = "1",

}

TY - JOUR

T1 - Bifurkationsprothese

T2 - Dacron versus Teflon (PTFE) - Präliminäre Ergebnisse einer prospektiven randomisierten Studie

AU - Karner, J.

AU - Polterauer, P.

AU - Kretschmer, G.

AU - Piza, F.

AU - Schemper, M.

PY - 1987/1

Y1 - 1987/1

N2 - After 3 years a preliminary evaluation of a prospective randomized study between PTFE-Y- and Dacron-Y-grafts in regard to function rate, complication and quality of material was performed. Both, function rate and complications showed no significant differences between both groups. In all patients with graft limb occlusion (1 early and 4 later occlusions) the function was gained by successful thrombectomy. Today Dacron-Y-prosthesis is available as collagen coated dacron double veloure graft, so presenting the same most important advantage PTFE prosthesis did (no preclotting). In cause of those above mentioned material characteristics both grafts seem to be equal in quality.

AB - After 3 years a preliminary evaluation of a prospective randomized study between PTFE-Y- and Dacron-Y-grafts in regard to function rate, complication and quality of material was performed. Both, function rate and complications showed no significant differences between both groups. In all patients with graft limb occlusion (1 early and 4 later occlusions) the function was gained by successful thrombectomy. Today Dacron-Y-prosthesis is available as collagen coated dacron double veloure graft, so presenting the same most important advantage PTFE prosthesis did (no preclotting). In cause of those above mentioned material characteristics both grafts seem to be equal in quality.

KW - Aortic aneurysma

KW - aorto-ilica occlusion disease

KW - Dacron-Y-prosthesis

KW - PTFE-Y-prosthesis

UR - http://www.scopus.com/inward/record.url?scp=0023187226&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023187226&partnerID=8YFLogxK

U2 - 10.1007/BF02658284

DO - 10.1007/BF02658284

M3 - Article

AN - SCOPUS:0023187226

VL - 19

SP - 8

EP - 10

JO - European Surgery

JF - European Surgery

SN - 1682-8631

IS - 1

ER -