Bifurkationsprothese: Dacron versus Teflon (PTFE) - Präliminäre Ergebnisse einer prospektiven randomisierten Studie

Translated title of the contribution: Aorto-Y-bifurcationgraft: Dacron versus PTFE -preliminary results of a prospective randomized study

J. Karner, P. Polterauer, G. Kretschmer, F. Piza, M. Schemper

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

After 3 years a preliminary evaluation of a prospective randomized study between PTFE-Y- and Dacron-Y-grafts in regard to function rate, complication and quality of material was performed. Both, function rate and complications showed no significant differences between both groups. In all patients with graft limb occlusion (1 early and 4 later occlusions) the function was gained by successful thrombectomy. Today Dacron-Y-prosthesis is available as collagen coated dacron double veloure graft, so presenting the same most important advantage PTFE prosthesis did (no preclotting). In cause of those above mentioned material characteristics both grafts seem to be equal in quality.

Original languageGerman
Pages (from-to)8-10
Number of pages3
JournalActa Chirurgica Austriaca
Volume19
Issue number1
DOIs
Publication statusPublished - Jan 1 1987

    Fingerprint

Keywords

  • Aortic aneurysma
  • Dacron-Y-prosthesis
  • PTFE-Y-prosthesis
  • aorto-ilica occlusion disease