Analytical separation of reduced and oxidized forms of glutathione from amino acid mixtures by overpressured thin-layer chromatography

Magdolna Ábraham, Béla Polyák, B. Szajáni, László Boross

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

A new method has been developed for the separation of reduced and oxidized forms of glutathione from amino acid mixtures. The samples were spotted on Kieselgel plates and developed in phenol-water = 7:3 containing SDS. The separation was performed in pressurized ultramicro chamber. The running time was shorter than that in a normal chamber, decreasing the possibility of diffusion. In addition to the two forms of glutathione, nine different kinds of amino acids could be separated. The method affords a possibility for rapid analysis of two forms of glutathione both in the clinical and industrial practice.

Original languageEnglish
Pages (from-to)2635-2645
Number of pages11
JournalJournal of Liquid Chromatography
Volume6
Issue number14
DOIs
Publication statusPublished - Dec 1 1983

Fingerprint

Thin layer chromatography
Glutathione Disulfide
Thin Layer Chromatography
Glutathione
Amino Acids
Phenol
Water

ASJC Scopus subject areas

  • Molecular Medicine

Cite this

Analytical separation of reduced and oxidized forms of glutathione from amino acid mixtures by overpressured thin-layer chromatography. / Ábraham, Magdolna; Polyák, Béla; Szajáni, B.; Boross, László.

In: Journal of Liquid Chromatography, Vol. 6, No. 14, 01.12.1983, p. 2635-2645.

Research output: Contribution to journalArticle

@article{ead779afde714fe1814836fa732a67b2,
title = "Analytical separation of reduced and oxidized forms of glutathione from amino acid mixtures by overpressured thin-layer chromatography",
abstract = "A new method has been developed for the separation of reduced and oxidized forms of glutathione from amino acid mixtures. The samples were spotted on Kieselgel plates and developed in phenol-water = 7:3 containing SDS. The separation was performed in pressurized ultramicro chamber. The running time was shorter than that in a normal chamber, decreasing the possibility of diffusion. In addition to the two forms of glutathione, nine different kinds of amino acids could be separated. The method affords a possibility for rapid analysis of two forms of glutathione both in the clinical and industrial practice.",
author = "Magdolna {\'A}braham and B{\'e}la Poly{\'a}k and B. Szaj{\'a}ni and L{\'a}szl{\'o} Boross",
year = "1983",
month = "12",
day = "1",
doi = "10.1080/01483918308064933",
language = "English",
volume = "6",
pages = "2635--2645",
journal = "Journal of Liquid Chromatography and Related Technologies",
issn = "1082-6076",
publisher = "Taylor and Francis Ltd.",
number = "14",

}

TY - JOUR

T1 - Analytical separation of reduced and oxidized forms of glutathione from amino acid mixtures by overpressured thin-layer chromatography

AU - Ábraham, Magdolna

AU - Polyák, Béla

AU - Szajáni, B.

AU - Boross, László

PY - 1983/12/1

Y1 - 1983/12/1

N2 - A new method has been developed for the separation of reduced and oxidized forms of glutathione from amino acid mixtures. The samples were spotted on Kieselgel plates and developed in phenol-water = 7:3 containing SDS. The separation was performed in pressurized ultramicro chamber. The running time was shorter than that in a normal chamber, decreasing the possibility of diffusion. In addition to the two forms of glutathione, nine different kinds of amino acids could be separated. The method affords a possibility for rapid analysis of two forms of glutathione both in the clinical and industrial practice.

AB - A new method has been developed for the separation of reduced and oxidized forms of glutathione from amino acid mixtures. The samples were spotted on Kieselgel plates and developed in phenol-water = 7:3 containing SDS. The separation was performed in pressurized ultramicro chamber. The running time was shorter than that in a normal chamber, decreasing the possibility of diffusion. In addition to the two forms of glutathione, nine different kinds of amino acids could be separated. The method affords a possibility for rapid analysis of two forms of glutathione both in the clinical and industrial practice.

UR - http://www.scopus.com/inward/record.url?scp=0020900896&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0020900896&partnerID=8YFLogxK

U2 - 10.1080/01483918308064933

DO - 10.1080/01483918308064933

M3 - Article

AN - SCOPUS:0020900896

VL - 6

SP - 2635

EP - 2645

JO - Journal of Liquid Chromatography and Related Technologies

JF - Journal of Liquid Chromatography and Related Technologies

SN - 1082-6076

IS - 14

ER -