Analog measurement of delayed antiproton annihilation time spectra in a high intensity pulsed antiproton beam

A. Niestroj, F. J. Hartmann, H. Daniel, B. Ketzer, T. Von Egidy, F. E. Maas, R. S. Hayano, T. Ishikawa, H. Tamura, H. A. Torii, N. Morita, T. Yamazaki, I. Sugai, K. Nakayoshi, D. Horváth, J. Eades, E. Widmann

Research output: Contribution to journalArticle

20 Citations (Scopus)

Abstract

An analog detection system has been developed to measure delayed antiproton annihilation time spectra for laser resonance spectroscopy of metastable antiprotonic helium atoms using the high-intensity pulsed beam of antiprotons from LEAR at CERN.

Original languageEnglish
Pages (from-to)411-414
Number of pages4
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume373
Issue number3
DOIs
Publication statusPublished - May 1 1996

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Instrumentation

Fingerprint Dive into the research topics of 'Analog measurement of delayed antiproton annihilation time spectra in a high intensity pulsed antiproton beam'. Together they form a unique fingerprint.

  • Cite this

    Niestroj, A., Hartmann, F. J., Daniel, H., Ketzer, B., Von Egidy, T., Maas, F. E., Hayano, R. S., Ishikawa, T., Tamura, H., Torii, H. A., Morita, N., Yamazaki, T., Sugai, I., Nakayoshi, K., Horváth, D., Eades, J., & Widmann, E. (1996). Analog measurement of delayed antiproton annihilation time spectra in a high intensity pulsed antiproton beam. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 373(3), 411-414. https://doi.org/10.1016/0168-9002(96)00066-6